Calibrator universal multifunctional de laborator si precizie Meatest M143
• Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 % • Extended current range from 0 to 20 A DC/AC with accuracy 0.02 % • Extended current range to 1000 A for calibration of clamp ammeters • Sinusoidal & Non-sinusoidal waveforms • Fix standard resistors 10 Ω to 100 MΩ in decimal values with calibration accuracy 0.02 % • Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C • Cold junction automatic compensation using external Pt1000 sensor • RTD temperature sensor simulator as option
| |||
![]() |
Calibrator multifunctional de inalta precizie Meatest M142
• 15ppm Accuracy • DC/AC voltage up to 1000 V • DC/AC current up to 30 A • Resistance up to 1000 MΩ, capacitance up to 100 uF • TC/RTD temperature sensors simulation • Frequency output up to 20 MHz • Electric power up to 240 V / 20 A • Built-in process multimeter • GPIB & RS232 interface
| |||
![]() |
Calibrator universal inalta precizie Meatest M142i
• 15ppm Accuracy • DC/AC voltage up to 1000 V • DC/AC current up to 30 A • TC temperature sensors simulation • RS232 interface
| |||
![]() |
Calibrator de laborator tensiune, curent, rezistenta, capacitate, frecventa Meatest M140
• 35ppm Accuracy • DC/AC voltage up to 1000 V • DC/AC current up to 20 A • Resistance up to 50 MΩ, capacitance up to 50 μF • TC/RTD temperature sensors simulation • Frequency output up to 20 MHz • Electric power up to 240 V / 10 A • Built-in process multimeter • GPIB & RS232 interface
| |||
![]() |
Calibrator de precizie laborator metrologie Meatest M140i
• 35ppm Accuracy • DC/AC voltage up to 1000 V • DC/AC current up to 20 A • TC temperature sensors simulation • RS232 interface
| |||
![]() |
Calibrator multifunctional universal Meatest M141
• 100ppm Accuracy • DC/AC voltage up to 750 V • DC/AC current up to 2 A • Fix standard resistors from 10 Ω to 10 MΩ in decade values • TC temperature sensors simulation • Frequency output up to 20 MHz • RS232 & GPIB (option) interface
| |||
![]() |
Decada rezistiva 10kV calibrare megohmmetre si testere izolatie Meatest M191
• Total resistance range 10.00 kΩ to 1000.0 GΩ • Resistance accuracy 0.1 to 5 % • Test voltage range 10 000 VDC + 5% • Test voltage accuracy indication 0.5 % + 10 V • Test current indication 4 digit from 0.01 pA to 99.99 mADC • Programmable high resistance decade box • Short current verification • Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR) • High voltage capacitance in three fix points 10, 50, 100 nF • HIPOT timer verification
| |||
![]() |
Calibrator impedanta RLC-metre: rezistenta, capacitate, inductanta Meatest M550
• Resistance standards from 0.1 Ω to 100 MΩ • Capacitance standards from 10 pF to 100 μF • Simulated inductance standards from 10 μH to 10 H • Four pair coaxial terminal connection, four terminal connection, two terminal connection • Calibration data from 20 Hz to 1 MHz • Interface bus GPIB and RS232 as standard
| |||
![]() |
Calibrator curent inalt clesti ampermetrici Meatest M151
• Current 8 mA … 120 A (AC/DC) • Frequency 15 Hz … 1 kHz • Simulated current and transconductance amplifier • Built-in process multimeter • Output capability 8 Vpk • Interface bus GPIB and RS232 as standard • With current coil it can be used for calibration of clamp meters up to 3000 A
|