Contor etalon portabil electricitate Applied Precision WS
• Lightweight compact size • Single-phase and three-phase versions, accuracy classes 0.2, 0.1, 0.05 • USB, RS-232 and optical interface • Vector diagram and signal shape display (oscilloscope mode) • Harmonics analysis in tabular and graphical format • Two universal input channels for any combination of Voltage and Current probes for Power or CT / VT ratio • Optional wireless communication interface and wireless scanning head • Optional portable printer
| |||
![]() |
Contor etalon de precizie clasa 0.1 Applied Precision xx20
• Class 0.1 • Precision 24-bit A/D conversion and digital signal processing • Continuous voltage and current ranges with auto-range functionality • Direct meter testing possibility (with supplied accessories) • Rack mountable with 2U form factor • Current measurement up to 120 A • Programmable meter constant
| |||
![]() |
Standard referinta clasa 0.05 0.02 0.01 calibrare contoare electrice Applied Precision RS 2x30
• Single-phase and three-phase versions in classes 0.05, 0.02, 0.01 • Current measurement up to 120, 160, 200 A or with optional Current Extender up to 240 A • Continuous voltage and current ranges with auto-range functionality • Independent input channels (three fully independent differential voltage input circuits in three-phase version) • Four independent fully programmable impulse outputs assignable to various quantities or constant frequency • Direct meter testing possibility (with supplied accessories) • Portable with special transport case
| |||
![]() |
Sursa tensiune si curent de inalta putere si precizie calibrat contoare Applied Precision PS
• 1 or 3 Phases • 0.2 0.05 0.02 0.01 Class • 100 VA to 2500 VA Output Power • Up to 500 V Output Voltage • Up to 200 A Output Current • Modular design with simple customization • Signal generation based on digital synthesis of the signal waveform
| |||
![]() |
Transformator de precizie tensiune secundar izolat monofazat Applied Precision D-MSVT 1110B
• DIN rail mounting possibility • Accuracy class 0.05 for differential measurement • Optimized for minimum residual capacitive current from the input to output circuits • Operation without external power supply • Selectable 1:1, 1:2, 1:0.5 transfer ratio • Built-in short circuit protection
| |||
![]() |
Transformator de tensiune si precizie cu rejectie mod comun testare contoare electricitate Applied Precision CMR-U 1110A
• DIN rail mounting possibility • Accuracy class 0.05 • Elimination of residual capacitive current from the input to output • Operation without external power supply • Unity transfer ratio of the CMR-U unit enables simple user test of functionality and accuracy • Built-in short circuit, overload and misconnection protection
| |||
![]() |
Transformator curent rejector mod comun testare contoare electricitate Applied Precision CMRI
• Standalone through-hole precision electronically compensated transformer with single • wire capability • Excellent accuracy and dynamics • Remote control via serial communication • Monitoring of individual contact resistance and power loss • Protection against open circuit and overload
| |||
![]() |
Rectificator unda curent direct testare contoare electrcitate Applied Precision HWR
• Ideal zero-voltage switch • Negligible power loss • Simple functionality modification
| |||
![]() |
Standard referinta faza zero Applied Precision ZPS 1101
• Broad-band operation up to 100th harmonic of mains frequency • Optional scalable current up to 240 A (720 A) • nominally zero phase angle between the current flowing through the resistor and the respective voltage on its voltage terminals
| |||
![]() |
Unitate evaluare locala eroare contoare electricitate testate Applied Precision OPS
• Remotely configurable either for reflexive mark or SO output of electromechanical or LED of electronic meters • Supplied with enhanced optical scanner working with coded signal which suppresses false light signals • Auto-calibration capability significantly increases the work comfort and productivity of the test system • Remotely controlled internal dividers enable evaluation of high constant meters with light impulses up to 1 kHz
| |||
![]() |
Sonde de curent AC flexibile Rogowski Applied Precision SymmProFlex
• Accuracy up to 0.2 % in amplitude and 0.1 ° in phase • No additional error for wire position • Symmetric flexible shielding pp for excellent suppression of strange electric fields • Symmetric sensor coil pp for excellent suppression of strange magnetic fields • Low noise, dual gain, high CMRR amplifier with precision integrator pp • Two sensor cable versions: high voltage Ø 12.6 mm and super flexible Ø 6 mm
| |||
![]() |
Stand automatizat masura, testare, calibrare contoare electricitate Applied Precision ELMA
• The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. • The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content.
| |||
![]() |
Stand compact masura, testare, calibrare contoare electricitate Applied Precision ELMA 8x01
• Accuraty of the power and energy reference meter can be optimized for laboratory demand up to 0.01% • Control of main and influencing quantities inclusive harmonics and predefined standard test patterns • Intelligent high resolution • Optical sensor with auto-calibration capability eliminating manual adjusment is not sensitive to external light conditions • Optical sensor evaluates high constant meter with LED impulses up to 2.5 kHz • Optical communitacion channel enables reading adjustment of registers
| |||
![]() |
Software gestionare date sisteme automate masura si testare contoare electricitate Applied Precision ELMA
• User friendly programs for Microsoft Windows. • Optional network support in distributed systems : client / server communication with central database via any type of computer network. • Multilingual user interface with predefined and user definable dictionaries enables immediate national and regional implementation. • Simple switch of display format from global characteristics of the process to detailed results on any meter.
| |||
![]() |
Sursa trifazata sarcina fantoma cu contor etalon integrat pt calibrare contoare electrice
• Multifunction portable signal source with integrated working standard of power and energy • Model PTE 2100A : 1-phase, 0.05% Class Accuracy • Model PTE 2100E : 1-phase, 0.02% Class Accuracy • Model PTE 2300A :3-phase, 0.05% Class Accuracy • Model PTE 2300E : 3-phase, 0.02% Class Accuracy • Power Source per phase: Voltage 3..300V, Current 1mA..120A • Reference Meter per phase : Voltage 30..300V, Current 1mA..120A
|