Cleste masurare priza de pamant Fluke 1630

Cod: Fluke 1630


 

Brosura produs PDF, 0.87 Mb

Descriere

  • A wide ground loop resistance range, from 0.025 O to 1500 O, to satisfy all requirements
  • Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars
  • Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting
  • Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications
  • User-defined HI / LO Alarm limits, for rapid measurement evaluation
  • Handy 'display hold' button for capturing readings in hard-to-reach places
  • Time saving memory function automatically records and stores measured values
  • Automatic self calibration ensures correct measurement every time
  • Overload protection: 200 A
  • Carrying case and resistance test loop included
  • = 8 hours battery life (continuous operation)
 

Accesorii standard

  • Rugged carrying case with shoulder strap
  • Resistance test loop
  • 9 V battery
  • User's manual
 

Optiuni recomandate

 

 

Alte produse FLUKE

APARAT DE MASURA PRIZE DE PAMANT FLUKE 1625-2 GEO

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

ANALIZOR CALITATE PUTERE SI ENERGIE ELECTRICA FLUKE 437 II

• 400 Hz measurement
• Power inverter efficiency: Simultaneously measure AC output power and DC input power
• PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms
• Energy loss calculator
• Troubleshoot real-time
• Highest safety rating in the industry
• Measure all three phases and neutral

 

FLUKE 190-202 190-202/S OSCILOSCOP PORTABIL DIGITAL 2X200 MHZ

• 2-canale izolate 200MHz
• Clasa de protectie CAT III 1000 V, CAT IV 600 V
• Multimetru digital dedicat cu 5000 de numărări la modele cu două canale
• Măsurători automate avansate, energie (Vpwm, VA, W, PF) ™ timp (mAs, V/s, w/s)
• Clasa de protectie IP-51 pentru praf şi lichide pentru a rezista in medii dificile
• Porturi USB izolate

 

FLUKE TIX520 CAMERA DE TERMOVIZIUNE 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE TI400 CAMERA INFRAROSU TERMOVIZIUNE 320X240

• Rezolutie detector : 320 X 240 pixeli
• Domeniu masura temepratura: -20 °C si +1200 °C
• Precizie : ± 2 °C sau 2%
• Sensibilitate : = 0,05 °C
• Banda spectru : 7,5 µm si 14 µm
• Ecran tactil capacitiv, rezistent, cu înalta rezolutie de 640x480

 

CLESTE AMPERMETRIC DE CURENT TRUE-RMS 600A FLUKE 373

• 600 A AC current measurement with fixed jaw
• 600 V AC and DC voltage measurement
• True-rms ac voltage and current
• 6000 O resistance measurement
• 1000 µF capacitance measurement

 

TESTER ELECTRIC 1000V TENSIUNE CURENT CONTINUITATE FLUKE T5-1000

• 1000V model
• Automatically measures V AC, V DC with precise digital resolution
• 100 A AC Current
• Displays resistance to 1000O

 

TERMOMETRU INFRAROSU FARA CONTACT FLUKE 572

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition

 

MULTIMETRU DIGITAL DE REFERINTA 8.5 DIGIT FLUKE 8508A

• 8.5 digit
• 2.7 ppm stability

 

POMPA PNEUMATICA CALIBRARE PRESIUNE FLUKE 700PTP-1

• Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
• ¼ -NPT female fitting for the reference gauge or pressure module
• ¼" NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke