  • -10 to 75 mV, 0 to 10 V Voltage source
  • -10 to 75 mV, 0 to 30 V Voltage measure
  • 0 to 24 mA Current measure
  • 0 to 3200 O Resistance measure / source
  • Easy to read dual display lets you view input and output simultaneously
  • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
  • Perform fast linearity tests with 25% and 100% steps
  • Execute remote tests with auto step and auto ramp
  • Power transmitters during test using loop power supply with simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Compact, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
 

Accesorii standard

  • AC70A Test Clips
  • One pair of stackable test leads
  • TL75 Test Leads
  • CE and CSA Markings
  • Manual
  • Users manuals on CD-ROM
  • NIST- traceable calibration report and data
 

Alte produse FLUKE

ESA710 ANALIZOR SECURITATE ELECTRICA APARATURA MEDICALA

• Ecran tactil de 5” cu interfață intuitivă pentru utilizator
• Design mic, portabil, ergonomic, cu mâner integrat
• Automatizarea fluxului de lucru activată de OneQA elimină necesitatea unui laptop
• Capacitatea wireless vă permite să rulați proceduri de testare pe teren și să sincronizați automat rezultatele

 

RLC-METRU 50 HZ..1 MHZ FLUKE 6306

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

TERMOMETRU INFRAROSU CU TERMOCUPLU DE CONTACT FLUKE 561 HVAC PRO

• IR Thermometer with K-type thermocouple capability
• IR thermometer for quick measurements up close, or at a distance, without a ladder
• Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
•  Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
• Single-point laser sighting
• Temperature range of -40 °C to 550 ° C (-40 °F to 1022 °F) covers most industrial and residential applications

 

TESTER ELECTRIC 600V TENSIUNE CURENT CONTINUITATE FLUKE T5-600

• 600V model
• Automatically measures V AC, V DC with precise digital resolution
• 100 A AC Current
• Displays resistance to 1000O

 

CLESTE CURENT CALIBRARE PROCES FLUKE 771

• 0 to 21 mA, 10 to 50 mA Current measure
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

LOGGER MONITORIZARE ENERGIE TRIFAZATA FLUKE MEMOBOX 1744/ 1744 BASIC

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

CALIBRATOR APARATE DE MASURA FLUKE 5500E

• Handheld digital multimeters
• Bench multimeters (up to 4½ digits)
• Clamp meters
• Electronic thermometers
• Oscilloscope recorders

 

CALIBRATOR DE PRESIUNE FLUKE 721

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

TESTER TENSIUNE SI CONTINUITATE FLUKE T120

• LED Bargraph
• Display: Fluke T120: 3½ digit LCD
• Voltage test
• Optical and acoustical continuity test