Calibrator portabil de temperatura Fluke 724

Cod: Fluke 724


 

Brosura produs PDF, 0.54 Mb

Descriere

  • -10 to 75 mV, 0 to 10 V Voltage source
  • -10 to 75 mV, 0 to 30 V Voltage measure
  • 0 to 24 mA Current measure
  • 0 to 3200 O Resistance measure / source
  • Easy to read dual display lets you view input and output simultaneously
  • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
  • Perform fast linearity tests with 25% and 100% steps
  • Execute remote tests with auto step and auto ramp
  • Power transmitters during test using loop power supply with simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Compact, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
 

Accesorii standard

  • AC70A Test Clips
  • One pair of stackable test leads
  • TL75 Test Leads
  • CE and CSA Markings
  • Manual
  • Users manuals on CD-ROM
  • NIST- traceable calibration report and data
 

Alte produse FLUKE

TELEMETRU LASER PORTABIL 100M FLUKE 421D

• Ability to measure up to 100 m (330 ft)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

SISTEM MENTENANTA SI INTRETINERE INSTALATII INDUSTRIALE FLUKE CNX 3000 GM

• • masuratori de tensiune c.a. si c.c. true-rms, la 1000 V
• • curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• • Masuratori de tensiune c.a. true-RMS pâna la 1000V
• • Masuratori de curent c.a. true-RMS la 2500 A


TERMOMETRE DIGITALE PORTABILE CU CONTACT FLUKE SERIA 50 II

• Relative time clock on MIN, MAX, and AVG provides a time reference for major events
• Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
• Measures J, K, T, and E-types of thermocouples
• Readout in ºC, ºF, or Kelvin (K)
• Data Logging up to 500 points of data with user adjustable recording interval(Fluke 53 II and Fluke 54 II)

 

FLUKE II500 CAMERA ACUSTICA INSPECTIE SI DETECTIE SCAPARI GAZ COMPRIMAT

• Detectare vizuală uÈ™oară, rapidă È™i sigură a scurgerilor de gaz comprimat.
• Ecranul tactil LCD de 7" afiÈ™ează o hartă sonoră SoundMapâ„¢ peste imagini vizuale, facilitând localizarea rapidă a scurgerilor.
• InterfaÈ›a intuitivă nu necesită instruire pentru echipele de întreÈ›inere.

 

NUMARATOR DE PARTICULE CALITATE AER FLUKE 985

• Six channels and particle size range of 0.3 - 10.0 µm
• Ultra-lightweight and ergonomic design
• Large 3.5 QVGC Color display
• 10,000 record storage
• USB/Ethernet charge cradle

 

MULTIMETRU DIGITAL PORTABIL CU DATA LOGGING 4.5 DIGIT FLUKE 287

• 4.5 digit large ¼ VGA display with white backlight
• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture

 

RECORDER CALITATE PUTERE TRIFAZATA FLUKE TOPAS 1760/ 1760 BASIC

• 8 input channels
• Fully IEC 61000-4-30 Class-A standard compliant
• Power quality statistics according to EN50160, DISDIP tables, ITIC, CEBEMA, ANSI
• 10 MHz, 6000 Vpk waveform capture
• GPS time synchronization
• records rms, min, max values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics Interharmonics

 

MULTIMETRU DIGITAL DE REFERINTA 8.5 DIGIT FLUKE 8508A

• 8.5 digit
• 2.7 ppm stability

 

LANTERNA CU LUMINA UV ULTRAVIOLETA PENTRU DETECTIE SCURGERI FREON FLUKE RLD2

• Six UV LEDs (395 nm wavelength) detect leak detection dyes
• Laser pointer clearly locates center of the UV field for accuracy
• Three LED flashlight with 100,000 hour LED life
• Operating temperature 0 ° C to 50 ° C
• Four operating modes: flashlight, UV light, laser light, UV/laser light combination


CLESTE AMPERMETRIC CURENT TRUE-RMS 400A FLUKE 323

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection