Calibrator de presiune Fluke 718

Cod: Fluke 718


 

Brosura produs PDF, 0.54 Mb

Descriere

  • Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
  • Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
  • Error % calculation for quicker pass/fail decision making in the field
  • Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
  • Min/Max/Hold to capture changing measurements
  • Switch test feature for quicker and more accurate pressure switch testing
  • New 1 and 300 PSI pressure ranges mean fewer extra tools required
  • 1, 30, 100 & 300 PSI ranges available
 

Accesorii standard

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
 

Optiuni recomandate

Fluke 718 1G

Pressure Calibrator -1 to 1 PSI, (-689 mbar to 689 mbar, -689 to 689 kPa)

Fluke 718 30G

Pressure Calibrator -12 PSI to 30 PSI, (-850 mbar to 2 bar, -85 to 20684 kPa)

Fluke 718 100G

Pressure Calibrator -12 PSI to 100 PSI, (-850 mbar to 7 bar, -85 to 68948 kPa)

Fluke 718 300G

Pressure Calibrator -12 PSI to 300 PSI, (-850 mbar to 20 bar, -85 to 206842 kPa )

 

Alte produse FLUKE

MULTIMETRU DIGITAL PORTABIL 4.5 DIGIT FLUKE 87V

• 4.5 digit
• 20,000 count resolution for precise measurements
• 0.05% basic accuracy
• True-rms ac voltage and current for accurate measurements on non linear signals
• Selectable filter for accurate voltage and frequency measurements on motor drives
• Built in thermometer lets you carry one less tool (TC probe included)

 

INREGISTRATOR MONITORIZARE PUTERE TRIFAZATA FLUKE 1735

• Record power and associated parameters for up to 45 days
• Measure harmonic distortion caused by electronic loads
• Voltage event capture
• View graphs and generate reports

 

CLESTE AMPERMETRIC CURENT TRUE-RMS 400A FLUKE 324

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement

 

KIT CALIBRARE PNEUMATICA PRESIUNI FLUKE 700PTPK

• Combine with any Fluke-700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
• Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
• Connect the 700G Series gauge directly to the included PTP-1 hand pump
• Includes hoses and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

RLC-METRU 50 HZ..1 MHZ FLUKE 6306

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

DETECTOR DE TENSIUNE FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC

 

TERMOMETRU INFRAROSU CU TERMOCUPLU DE CONTACT FLUKE 566/ FLUKE 568

• Measure -40 °C to 800 °C /-40 °F to 1472 °F (568) or -40 °C to 650 °C/-40 °F to 1202 °F (566)
• Easily access advanced features with the soft-key buttons and dot-matrix display
• Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)
• Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments

 

TELEMETRU LASER PORTABIL 60M FLUKE 416D

• Ability to measure up to 60 m (200 ft) with increased accuracy of up to 1.5 mm (0.06 in)
• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

LANTERNA CU LUMINA UV ULTRAVIOLETA PENTRU DETECTIE SCURGERI FREON FLUKE RLD2

• Six UV LEDs (395 nm wavelength) detect leak detection dyes
• Laser pointer clearly locates center of the UV field for accuracy
• Three LED flashlight with 100,000 hour LED life
• Operating temperature 0 ° C to 50 ° C
• Four operating modes: flashlight, UV light, laser light, UV/laser light combination


CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure