Description
Cable Identifier
The unmistakable identification of a cable prior to cutting or mounting is an absolute safety related task. A wrong selection can result in fatal consequences for the operator and caused the loss of supply for the connected customers. For the easy, reliable and safe selection of cables, SebaKMT developed the CI cable selection system.
The CI TX Transmitter generates impulses of up to 100 A. Due to the limitation of impulse voltage to 55 V, the voltage is below the dangerous contact voltage limit, as specified by the German VDE 0100.
The CI RX receiver uses a flex clamp to measure the selection signals. The processor of the CI RX does an evaluation if the impulse shape, polarity, amplitude and frequency and generates an absolute reliable statement.
Key benefits:
Inexpensive cable selection system
Easy to operate
Safe handling
Very small
Standard accessories
Basic CI set for identification on de-energised cables
»» Transmitter CI TX
»» Receiver CI RX with
230 mm flex clamp
»» Supplied with all
necessary connection
cables, mains leads,
clips and clamps
»» Case
Basic LCI set for identification on energised cables
»» Transmitter LCI TX
»» Receiver CI RX with
230 mm flex clamp
»» Supplied with all
necessary connection
cables, mains leads,
clips and clamps
»» Case
Complete CI and LCI Set
»» Transmitter CI TX & LCI TX
»» Receiver CI RX with
230 mm flex clamp
»» Supplied with all
necessary connection
cables, mains leads,
clips and clamps
»» Case
Recommended options
Optional accessories
»» 120 mm Flex-Coupler
»» Contact sensor PAS CI
»» Twisted field sensor TFS CI
»» NH test adapter
»» ISO 9001: 2008
»» LCI TX 440 for selection between phases
More products SEBAKMT
|
SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM
• Small, light and portable |
|
SEBA KMT TAN DELTA CABLE CONDITION DIAGNOSIS SYSTEM
• Very accurate measurement |
|
SEBA KMT VFL CR-28..60 VLF TEST SYSTEMS FOR MEDIUM VOLTAGE CABLE TESTING
• VLF CR-28 up to cable series 15 kV |
|
SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM
• Testing, prelocation and pinpointing of sheath faults |
|
SEBA KMT VM-850 LOCATION UNDERGROUND PIPES AND CABLES
• Easy to use |
|
SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY
• simplified version of the standard VLF test |
|
SEBA TELEFLEX VX CABLE REFLECTOMETER FOR FAULT LOCATION SYSTEMS
• Range : 20 m … 1280 km |
|
SEBA SURGEFLEX SFX-32 SPG-32 CABLE FAULT LOCATING SYSTEM
• »» DC-testing up to 32 kV |
|
SEBA TELEFLEX SX CABLE REFLECTOMETER FOR FAULT LOCATION MEGGER
• ARMslide technology with 15 traces in one ARM shot |
|
SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF
• Easy-go single button operation |