Seba BPS 5000-d Burn and Proof Test System on Medium Voltage Cables BPS-5000d BPS500d BPS 5000d-VLF

Code: Seba-KMT BPS5000-d BPS-5000d BPS500d BPS5000d-VLF


 

Datasheet PDF, 0.31 Mb
     

Description

BPS 5000-d

The BPS system is typically installed into cable test systems, but is also available as stand alone version for burning and testing.

The digital control allows an easy operation as burn unit for the conversion of difficult to locate cable faults and permits the operation of aconnected HV DC test system and a VLF cosine rectangular test system. 

Key benefits:

  • Easy-go single button operation
  • Protocolling of the test results
  • Data transfer via Bluetooth
  • DC burn current up to 6 A
  • AC burn current up to 110 A
  • Sheath fault pinpoiting mode

 

 

 

 

 

Standard accessories

 

 

Recommended options

Options

»» Device for system integration

»» Stand-alone system (mobile)

»» VLF test system

»» DC voltage test

»» ESG NT for sheath fault location

 

 

 

 

More products SEBAKMT

SEBA KMT VLOCML2 PIPELINE LOCATION AND TRACING FOR UNDERGROUND PIPES AND CABLES

• Location of passive markers which are used by utility
• companies for labelling underground lines
• Colour-coded display of the signal strength
• Specifi c line location mode
• Specifi c marker location mode
• Mode for simultaneous location of lines and markers

 

SEBA KMT HV TEST SET 50KV 80KV 110KV DC HIGH VOLTAGE TESTER

• available in three versions: 50kV 80kV 110kV DC
• Highest safety by monitoring functions and easy operation
• Quick and easy mounting with compact and simple setup
• Meeting individual needs by modular design

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT ESG NT PINPOINTING EARTH FAULT LOCATOR IN SHEATH OF UNDERGROUND CABLES

• high accuracy pinpointing of a sheath fault
• Automatic adaptation to voltage level
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• High-contrast color display

 

SEBA T18/5 SURGE WAVE VOLTAGE GENERATOR FOR CABLE FAULT LOCATING

• Voltage Ranges : 0..3kV / 0..6kV / 0..12kV
• Energy : 1000 Joules


SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM

• Testing, prelocation and pinpointing of sheath faults
• Voltage up to ±10 kV DC
• High current of up to 750 mA
• Only one HV connection cable
• Automatic measurement and protocolling

 

SEBA KMT EASYLOC RXTX PIPELINE LOCATION AND TRACING FOR UNDERGROUND PIPES AND CABLES

• Make optimum preparations for your building work, quickly and reliably
• Avoid cable damage and help to minimise costly accidents and inconvenient delays
• Depth measurement at the push of a button, even without a transmitter
• 33 kHz - compatible with other location systems
• Large display with automatic backlight
• Quick and simple to operate

 

SEBA DIGIPHONE+ SURGE WAVE RECEIVER FOR ACOUSTIC AND ELECTROMAGNETIC FAULT PINPOINTING IN CABLES

• Perfect acoustic quality and noise immunity
• Automatic mute function to protect your ears
• Bright, transflective sun readable display
• Easiest handling with automatic adjustment
• Earphone volume limitation to 84 dB(A)

 

SEBA KMT PD SURVEYOR AIR PARTIAL DISCHARGE DETECTOR FOR MEDIUM VOLTAGE CABLES, SWITCHGEAR, PLANTS

• Three PD sensor technologies in one device
•  Early detection of PD activity
•  Universal application - can be applied to
• MV cables, MV switchgear & other types of MV plants
•  Directs maintenance resources straight to the problem areas
•  Easy to use

 

SEBA KMT HVB-10 10KV CABLE FAULT LOCATION, STEATH TESTING AND PINPOINTING MEGGER HVB10

• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines