Seba KMT vLoc-9800 Line Location and Tracer for Underground Pipes and Cables

Code: Seba-KMT vLoc-9800


 

Datasheet PDF, 0.48 Mb

Description

vLoc-9800

The vLoc-9800 is a new entry in the vLoc product line, building upon the Metrotech tradition of performance and convenience. In many sectors, underground cables are located using a method developed by Metrotech 30 years ago: the Distance Sensitive Left/Right GuidanceTM. Most manufacturers offer left/right guidance via a peak/zero antenna set. 

The vLoc-9800 has two horizontal guidance antennae, positioned at a certain distance from each other. This enables a precise distinguishing of left from right. The guidance antennae and the extremely high sensitivity ensure a clear and fast response for easier and precise location. 

Key benefits:

  • Clearly laid out user interface
  • Automatic or manual amplification options
  • Depth and amperage at the press of a button
  • Distance Sensitive Left/Right GuidanceTM
  • Sheath fault location (optional)

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA KMT VLOCML2 PIPELINE LOCATION AND TRACING FOR UNDERGROUND PIPES AND CABLES

• Location of passive markers which are used by utility
• companies for labelling underground lines
• Colour-coded display of the signal strength
• Specifi c line location mode
• Specifi c marker location mode
• Mode for simultaneous location of lines and markers

 

SEBAKMT HL50-BT PORTABLE WATER LEAK DETECTOR

• Simple operation with just two function buttons
• Frequency filter
• Always ready for use thanks to rechargeable battery
• External ground microphones can be connected for professional leak detection

 

SEBA KMT VFL SINUS 45KV SINE WAVE CABLE TEST SYSTEMS

• VLF sine wave 45 kV with integrated tanDelta
• compact, robust, and portable
• high-performance test and diagnostic system for medium voltage cables
• Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
• Automatically adjusts the test frequency to the cable length
• Eliminates hazards to the user and guarantees limited damage to the cable
• Easy field operation with no need for external computer

 

SEBA KMT HV TESTER 25KV HIGH VOLTAGE DC TESTER

• DC output voltage of 0 - 25 kV
• Portable HV Tester
• DC and insulation testing of cables, joints, electrical fixtures, etc.
• High flexibility with built-in battery

 

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA KMT HPG 70-K 70KV DC HIGH VOLTAGE HIPOT TESTER

• fully insulated test set for DC testing up to 70 kV
• Testing of cables, switchgear, current-transformers, MV plant/ component testing,
• Highest safety thanks to fully insulated design
• Compact and lightweight
• Separate control and HV-unit
• Voltage continuously adjustable
• Expandable with a VLF CR attachment for VLF testing on MV cables

 

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km

 

SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES

• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification


SEBA KMT VFL CR-20 VERY LOW FREQUENCY CABLE TESTING SYSTEM

• VLF Test System 20 kV
• high test capacity of 3 µF permits the simultaneous testing of all three phases
• method is officially recommended by the two VDE Standards 0276-620 and 0276-621
• VLF is the most economic method for testing PE and XLPE cables