Seba KMT vLoc-9800 Line Location and Tracer for Underground Pipes and Cables

Code: Seba-KMT vLoc-9800


 

Datasheet PDF, 0.48 Mb

Description

vLoc-9800

The vLoc-9800 is a new entry in the vLoc product line, building upon the Metrotech tradition of performance and convenience. In many sectors, underground cables are located using a method developed by Metrotech 30 years ago: the Distance Sensitive Left/Right GuidanceTM. Most manufacturers offer left/right guidance via a peak/zero antenna set. 

The vLoc-9800 has two horizontal guidance antennae, positioned at a certain distance from each other. This enables a precise distinguishing of left from right. The guidance antennae and the extremely high sensitivity ensure a clear and fast response for easier and precise location. 

Key benefits:

  • Clearly laid out user interface
  • Automatic or manual amplification options
  • Depth and amperage at the press of a button
  • Distance Sensitive Left/Right GuidanceTM
  • Sheath fault location (optional)

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

SEBA KMT HV TESTER 25KV HIGH VOLTAGE DC TESTER

• DC output voltage of 0 - 25 kV
• Portable HV Tester
• DC and insulation testing of cables, joints, electrical fixtures, etc.
• High flexibility with built-in battery

 

SEBA SURGEFLEX SFX-15 SFX-25 CABLE FAULT LOCATING SYSTEM

• » DC-Testing up to 15 kV / 25 kV (depending on model)
• » Prelocating
• » - Reflection measurement
• » - ARM-Measurement (Arc reflection method)
• » - ICE Impulse current method
• » Cable tracing (optional)
• » Pin-pointing
• » - Distance and acoustic measurement
• » - Audio frequency methods (optional)
• » Battery and mains operation

 

SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES

• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation

 

SEBA KMT HV TEST SET 50KV 80KV 110KV DC HIGH VOLTAGE TESTER

• available in three versions: 50kV 80kV 110kV DC
• Highest safety by monitoring functions and easy operation
• Quick and easy mounting with compact and simple setup
• Meeting individual needs by modular design

 

SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY

• simplified version of the standard VLF test
• Easy to operate
• Configurable test sequences
• Compact, rugged and lightweight design
• AC, DC and sheath testing in one single system
• Reporting via USB or Winkis

 

SEBA KMT VFL SINUS 45KV SINE WAVE CABLE TEST SYSTEMS

• VLF sine wave 45 kV with integrated tanDelta
• compact, robust, and portable
• high-performance test and diagnostic system for medium voltage cables
• Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
• Automatically adjusts the test frequency to the cable length
• Eliminates hazards to the user and guarantees limited damage to the cable
• Easy field operation with no need for external computer

 

SEBA KMT OWTS M60 DIELECTRIC DIAGNOSIS AND PARTIAL DISCHARGE MEASURING SYSTEM

• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight

 

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter