Seba digiPHONE+ Surge wave receiver for acoustic and electromagnetic fault pinpointing in cables

Code: Seba-KMT digiPHONE+ digiPHONE-Plus DDP-CU DDP-SU


 

Datasheet PDF, 0.39 Mb
     

Description

Surge wave receiver for acoustic and electromagnetic fault pinpointing

 

 

Features

 

·                     Perfect acoustic quality and noise immunity

·                     Automatic mute function to protect your ears

·                     Bright, transflective sun readable display

·                     Easiest handling with automatic adjustment

·                     Earphone volume limitation to 84 dB(A)

 

 

The new digiPHONE+, the new definition of silence!

The innovation for the cable fault pinpointing!

A combination of different technologies for the efficient noise suppression provides you with a maximised, perfect acoustic performance, which passes only the fault noise.

No traffic!

No high heels!

No talking!

You hear only the fault, nothing else -

Your ears will love it!

The technologies of the digiPHONE+

BNR - Background Noise Reduction

The new, intelligent BNR technology with filtering and background noise suppression produces an undisturbed acoustic experience, and lets only the fault sound to your ears.

APM Automatic Proximity Mute

The second silent technology in the new digiPHONE+. As soon as one approaches the handle, the sound switches off, before the hand touches the handle. No cracks or bangs. After removing the hand, a short delay ensures that the digiPHONE+ sensor is standing stable and possible mechanical oscillations have ceased, before the headset is activated.

Housing

The new housing concept of the sensor in connection with a floating microphone suspension reduces the body sound of the sensor itself and provides a solid standing of the digiPHONE+ sensor even on sloped surfaces.

Tracing

The left-right indication keeps the operator always on top of the cable and the compass indicates the fault direction. Distance to fault can be displayed in meter/feet

 

advandages at a glance

                        Easiest Operation

                        Automatic adjustment of values

                        BNR - Background Noise Reduction

                        APM - Auto Proximity Mute when approaching the handle. ("Bang" protection)

                        Bright, sun readable display

                        84 dB(A) limiter (according to noise and vibration protection laws, e.g. "OSHA")

                        Distance measurement in milliseconds or meter/feet

                        Easy tracing with left-right indicator

                        "Compass" for fault direction indication

                        High ground stability of the sensor up to 45°

 

 

Standard accessories

Scope of delivery

                        Receiver Unit DPP-CU with shoulder strap

                        Headset KR22-5

                        Sensor Unit DPP-SU with:

                        Telescopic handle

                        Tips (18 mm and 75 mm), tripod

                        Sensor connection cable

                        Set of batteries

                        Carrying bag with foam inserts

                        Ground plate

                        Manual

 

Accessories

                        Vehicle Installation Kit (instead of the carrying bag)

 

 

Recommended options

 

 

More products SEBAKMT

SEBA T18/5 SURGE WAVE VOLTAGE GENERATOR FOR CABLE FAULT LOCATING

• Voltage Ranges : 0..3kV / 0..6kV / 0..12kV
• Energy : 1000 Joules


SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA KMT PD LOC PARTIAL DISCHARGE PINPOINTING SYSTEM FOR RPECISE LOCATION OF PD FAULTS IN MEDIUM VOLTAGE CABLES

• Precise PD pinpointing in mixed cable networks
• Location of faults in joints of single core cables
• Easy handling in the ?eld

 

SEBA KMT T22/1 AC HIGH VOLTAGE TESTING SYSTEM

• Compact and lightweight
• Continuous testing with AC voltages up to 75 kVrms at 1 kVA
• Expandable with a second transformer for testing up to 150 kVrms
• Built-in overload protection
• DC testing up to 80 kV with optional rectifier

 

SEBA KMT FERROLUX FLE 10 AUDIO FREQUENCY RECEIVER FOR CABLE LOCATION, SELECTION, SHEATH FAULTS

• Precise direction guidance with right/left arrows
• "SignalSelect" for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• "DirectSignal" for effective line location

 

SEBA KMT VFL CR-20 VERY LOW FREQUENCY CABLE TESTING SYSTEM

• VLF Test System 20 kV
• high test capacity of 3 µF permits the simultaneous testing of all three phases
• method is officially recommended by the two VDE Standards 0276-620 and 0276-621
• VLF is the most economic method for testing PE and XLPE cables

 

SEBA KMT VCAM-5 SEWER PIPELINE VIDEO INSPECTION CAMERA

• One touch recording
• Lightweight and compact design
• Records to USB, SD or HDD
• JPEG still image capture
• Wi-Fi and Ethernet interface

 

SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM

• Testing, prelocation and pinpointing of sheath faults
• Voltage up to ±10 kV DC
• High current of up to 750 mA
• Only one HV connection cable
• Automatic measurement and protocolling

 

SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle