YOKOGAWA Clamp-on Tester CL155 (AC, True RMS, 2000A)

Cod: YOKOGAWA CL155


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

2.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

?.5% rdg ± 0.5mV (50/60Hz)
?.5% rdg ± 0.5mV (40~1kHz)

Method of detection

True RMS

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2.0% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W)x247(H)x49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA CLAMP-ON TESTER CL155 (AC, TRUE RMS, 2000A)

• AC current measurement with current ranges up to 2000A
• AC/DC voltage and resistance measurements
• True RMS display
• 54mm in diameter of measurable conductor
• DC output function
• Data hold function

 

YOKOGAWA 2558A AC VOLTAGE CURRENT STANDARD

• Output Divider
• Direct Readout of the Deviation
• Digital Display of Output
• Common Current Output Terminals
• High Accuracy
• High Stability

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA AQ4280 SURSA OPTICA PORTABILA

• - SC, FC or other connector adapter
• (Removable for convenient access for cleaning)
• AQ4280 A/B/C : FC/PC, SC/PC, ST/PC
• - Rubber protector to prevent damage when dropped
• - Carrying pouch to house unit and connector adapters

 

YOKOGAWA GS610 SOURCE MEASURE UNIT

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% (DC voltage generation)
• Sweep output at up to 100-µ intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in the internal memory

 

YOKOGAWA DIGITAL RESISTANCE METER 7556

• Wide operating rangeability (1 Ohm range to 100 M Ohm range)
• Full remote controlability via the standard RS232C serial, or optional GP-IB interfaces
• Software based calibration
• Printer output of measurement, and statistical analysis results

 

YOKOGAWA MANOMETRU DIGITAL MT210 MT210F

• ±0.01%, with a maximum allowable input of 500 kPa (130 kPa-range model)
• Offering low differential pressure of 1 kPa to a high gauge pressure of 3000 kPa
• Normal speed, medium speed, and high speed (MT210F series)

 

YOKOGAWA AQ6360 TELECOM PRODUCTION OPTICAL SPECTRUM ANALYZER 1200 - 1650 NM

• Wavelength range: 1200 to 1650 nm
• Wavelength resolution: 0.1 to 2 nm
• High wavelength accuracy: ±0.02 nm
• High dynamic range: 55 dB
• Wide measurement range: +20 to -80 dBm

 

YOKOGAWA AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA - DIGITAL LUX METERS 51000 51011 51012 51021

• Wide measurement range, high accuracy
• Spectral response characteristics for visible range
• Good oblique incident light characteristics
• USB communication and USB power supply
• Recorder output