YOKOGAWA Clamp-on Tester CL155 (AC, True RMS, 2000A)

Cod: YOKOGAWA CL155

 

Brosura produs 1 PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

2.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

?.5% rdg ± 0.5mV (50/60Hz)
?.5% rdg ± 0.5mV (40~1kHz)

Method of detection

True RMS

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2.0% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W)x247(H)x49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA AQ1000 REFLECTOMETRU FIBRA OPTICA IEFTIN

• Wavelengths: 1310 / 1550 nm
• Dynamic ranges: 32 / 30 dB
• Size: 185 mm (W) × 116 mm (H) × 56 mm (D) ( 7.3" (W) × 4.6" (H) × 2.2" (D) )
• Weight: 660 g ( 1.46 Lbs )

 

YOKOGAWA - DLM2000 OSCILOSCOP DIGITAL MIXT CU CANALE ANALOGICE SI DIGITALE

• Lineup includes 200 MHz, 350 MHz, 500 MHz bandwidth models
• Lightweight and compact
• Large 8.4-inch LCD display
• Long memory: Up to 250 M points (with /M3 option)
• High speed sampling: Up to 2.5 GS/s (1.25 GS/s with 4 ch)

 

YOKOGAWA - WT3000E ANALIZOR DE PUTERE DE PRECIZIE

• Basic power accuracy: 0.01% of reading
• Both 2 A and 30 A input elements can be installed in a single unit
• Good readability: 8.4-inch LCD and the range indicator LEDs
• Simultaneous measurement with 2 units (Up to 8 power input elements)
• Store function: 50 ms data storing interval

 

YOKOGAWA AQ2180 POWERMETRU OPTICA PORTABIL

• Two versions of Power Meters to suit test application
• Versatile data storage and transfer
• Auto switching of measurement wavelength
• Power source

 

YOKOGAWA GS610 SOURCE MEASURE UNIT

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% (DC voltage generation)
• Sweep output at up to 100-µ intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in the internal memory

 

YOKOGAWA CLAMP-ON TESTER CL220 (AC/DC 300A)

• AC/DC current measurements with current ranges up to 300A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display
• Sleep function

 

YOKOGAWA AQ6150 SERIES OPTICAL WAVELENGTH METER

• High wavelength accuracy of ±0.3pm
• Cope with modulated light and optical filter measurement
• Simultaneous measurement of up to 1024 wavelengths
• Increase throughput with high speed measurement

 

YOKOGAWA DMM PORTABIL TY530

• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety
• Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA150 (HANDHELD)

• Vertical Hand-Held Calibrator
• Simultaneous Source and Measurement for Process Devices
• Loop Power Supply Function