Cod: YOKOGAWA CL155
Descriere
Features:
|
Display (LCD, Digital Counts) |
3999 |
|
AC Current Accuracy (400A Reference) |
1.0+3(50/60Hz) |
|
AC Current Accuracy (2000A Reference, 0~1500A) |
2.0+3(50/60Hz) |
|
AC Voltage Accuracy (40/400V/750V Reference) |
1.0+2(50/60Hz) |
|
DC Voltage Accuracy (40/400V/1000V Reference) |
1.0+2 |
|
Resistance Accuracy (400/4k/40k/400kO reference) |
1.5+2, Beeps at below 50± 35O (continuity check) |
|
DC Output Accuracy (400A, 0~400mV Reference) |
?.5% rdg ± 0.5mV (50/60Hz) |
|
Method of detection |
True RMS |
|
Response Time |
Approx. 2 seconds |
|
Range Switching |
Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range) |
|
Data hold |
On all range |
|
Operating temperature and humidity |
0-40°C, 85% RH or less (no condensation) |
|
Influence of external magnetic field |
1A or less at 400A/m |
|
Influence of conductor position |
± (2.0% rdg + 3dgt) or less |
|
Safety Standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
1000Vrms or less |
|
Withstanding voltage |
5.55kV AC for one minute |
|
Power Supply |
R6P(SUM-3)x2 or LR6x2 |
|
Battery Life1 |
150 hours |
|
Consumed current |
Approx. 5mA |
|
Sleep Function |
Automatically powered down in about 10 minutes after the last switch operation |
|
Diameter of measurable conductor |
54mm at maximum |
|
Dimensions |
Approx. 105(W)x247(H)x49(D)mm |
|
Weight (Approx.) |
470g |
|
Accessories |
Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User's manual (IM CL120), batteries |
|
Order Notes |
Each item selected MUST be ordered as a separate line item. |
|
Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
Alte produse YOKOGAWA
|
YOKOGAWA CLAMP-ON TESTER CL155 (AC, TRUE RMS, 2000A)
• AC current measurement with current ranges up to 2000A |
|
YOKOGAWA 2558A AC VOLTAGE CURRENT STANDARD
• Output Divider |
|
YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)
• 0.2% Accuracy, 0.01mA Resolution |
|
YOKOGAWA AQ4280 SURSA OPTICA PORTABILA
• - SC, FC or other connector adapter |
|
YOKOGAWA GS610 SOURCE MEASURE UNIT
• Source and sink operation up to 110 V/3.2 A (four-quadrant operation) |
|
YOKOGAWA DIGITAL RESISTANCE METER 7556
• Wide operating rangeability (1 Ohm range to 100 M Ohm range) |
|
YOKOGAWA MANOMETRU DIGITAL MT210 MT210F
• ±0.01%, with a maximum allowable input of 500 kPa (130 kPa-range model) |
|
YOKOGAWA AQ6360 TELECOM PRODUCTION OPTICAL SPECTRUM ANALYZER 1200 - 1650 NM
• Wavelength range: 1200 to 1650 nm |
|
YOKOGAWA AQ2200-651 SG MODULE
• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz |
|
YOKOGAWA - DIGITAL LUX METERS 51000 51011 51012 51021
• Wide measurement range, high accuracy |