Features:

  • AC/DC current measurements with current ranges up to 300A
  • 24mm in diameter of measurable conductor
  • Light weight & compact design
  • Mean value display
  • Sleep function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)

 

Description

AC/DC Mini Clamp-on

Method of detection

Mean Value

Display

LCD (Digital display: 3999 counts)

DC Current Range

40/300A

DC Current Resolution

0.01A

Response Time

Approx. 2 second

Range Switching

Auto-range

Data hold

On all range

Operating temperature and humidity

0 - 40°C, 90% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400 A/m

Influence of conductor position

±(2% rdg + 5dgt) or less

Safety Standard

Conforms EN61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

300 Vrms or less

Withstanding voltage

3.7 kV AC for one minute

Power Supply

LR-44 x 2 (3V)
SR-44 x 2

Battery Life

Approx. 11 hours (continuous)

Consumed current

Approx. 9 mA

Sleep Function

Automatically powered down in about 5 minutes after the last switch operation

Diameter of measurable conductor

24 mm at maximum

Dimensions

Approx. 59 (W) x 147 (H) x 25 (D) mm

Weight

Approx. 100 g

Accessories

Batteries, carrying case (93033)
User's manual (IM CL235)

 

 

Alte produse YOKOGAWA

YOKOGAWA 2560A HIGH VOLTAGE AND HIGH CURRENT PRECISION DC CALIBRATOR

• Wide output range of voltage and current generation
• Dials and switches for each digit and function
• High accuracy, stability, and resolution
• Various effective functions for analog meters calibration.

 

YOKOGAWA - DLM2000 OSCILOSCOP DIGITAL MIXT CU CANALE ANALOGICE SI DIGITALE

• Lineup includes 200 MHz, 350 MHz, 500 MHz bandwidth models
• Lightweight and compact
• Large 8.4-inch LCD display
• Long memory: Up to 250 M points (with /M3 option)
• High speed sampling: Up to 2.5 GS/s (1.25 GS/s with 4 ch)

 

YOKOGAWA - DLM4000 OSCILOSCOP DIGITAL SEMNALE MIXTE

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows

 

YOKOGAWA - DL350 INREGISTRATOR PORTABIL

• A4-sized compact chassis
• Simultaneous isolated inputs maximum
• AC/DC/Battery operated
• Vibration resistant

 

YOKOGAWA - DIGITAL LUX METERS 51000 51011 51012 51021

• Wide measurement range, high accuracy
• Spectral response characteristics for visible range
• Good oblique incident light characteristics
• USB communication and USB power supply
• Recorder output

 

YOKOGAWA MINI CLAMP-ON TESTER CL120 (200A)

• Exclusive model for AC current measurement with current ranges up to 200A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display

 

YOKOGAWA - DL850E DL850EV SCOPECORDER

• Voltage & Currents
• Sensor Outputs
• Temperature, Vibration/Acceleration, Strain, Frequency
• Logic Signals & CAN / LIN and SENT

 

YOKOGAWA AQ2211 FRAME CONTROLLER (3 SLOTS)

• Easy-to-view color display
• USB port for data storage
• Measurement module "hot-swapping" capability
• Remote monitoring and measurement through a LAN

 

YOKOGAWA DM7560 DIGITAL MULTIMETER 6.5 DIGIT

• Full-color,high-resolution display with flexible display formats
• High-speed data logging with up to 30 k points per second
• High-capacity internal memory up to 100 k points
• Trend / histogram analysis available both in real-time and offline

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA71 CA51

• Autostep function
• Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
• Online communication (CA71 only) RS-232C-compliant optically isolated interface
• Sweep function
• Linearly increases or decrease the output. The increasing/decreasing time can be set to either 16 or 32 seconds.
• Memory function
• Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).
• Temperature monitor function