Descriere

Display (LCD, Digital Counts)

1999

AC Current Accuracy (200A Reference)

1.5+6(50/60Hz)
2.0+5(40~1kHz)

AC Current Accuracy (600A Reference)

1.0+3(50/60Hz)
2.0+5(40~1kHz)

AC Voltage Accuracy (200V/600V Reference)

1.0+2(50/60Hz)
1.5+4(40~1kHz)

Resistance Accuracy (200O reference)

1.2+4, Beeps at below 30O (continuity check)

Method of detection

Mean Value

Response Time

Approx. 1 seconds (approx. 2 seconds on resistance range)

Range Switching

Manual-range

Data hold

On all range

Operating temperature and humidity

-10-50°C. (no condensation)
up to 30°C, 90% RH
up to 40°C, 75% RH
up to 50°C, 45% RH

Influence of external magnetic field

2A or less at 400A/m

Influence of conductor position

± 2% or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

600Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

6F22(006P)9Vx1 or 6LR61x2

Battery Life1

200 hours

Consumed current

Approx. 2mA

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

30mm at maximum

Dimensions

Approx. 93(W)x210(H)x40(D)mm

Weight (Approx.)

400g

Accessories

Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL130), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA 2553A PRECISION DC CALIBRATOR

• Digital Display of Output
• High Basic Accuracy
• High Stability and Low Noise
• High Resolution

 

YOKOGAWA AQ1100 SET TESTARE PIERDERI PE FIBRA OPTICA

• 5.7 inch color LCD for easy viewing
• Multi-Language support
• Multi-core fiber measurement with a pair set
• USB port for data storage

 

YOKOGAWA MINI CLAMP-ON TESTER CL120 (200A)

• Exclusive model for AC current measurement with current ranges up to 200A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display

 

YOKOGAWA TESTER ANALOGIC SCURGERI CURENTI 322610 (ANALOG)

• ± 2.5% full scale accuracy
• 100µA full scale value
• Shockproof indicator using taut band movement
• Built-in overload protection circuit
• Handy and easy to carry

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA AQ2170 SERIES PORTABLE OPTICAL POWER METER (SIMPLE & COMPACT)

• Two versions of Power Meters to suit test application
• Compact and lightweight
• Rubber protector to prevent damage when dropped

 

YOKOGAWA - WT300E POWERMETRU DIGITAL

• Fast display and data update rate: The fast display and a maximum data update rate of 100ms on the WT300E series, offers a short tact time in testing procedures.
• MAX hold function: The maximum values of RMS/PEAK Voltage & Current, Active Power, Reactive Power and Apparent Power can be held.
• Line filter and frequency filter capabilities: These filter functions will cut off unnecessary noise & harmonic components for fundamental waveform measurements.

 

YOKOGAWA AQ4280 SURSA OPTICA PORTABILA

• - SC, FC or other connector adapter
• (Removable for convenient access for cleaning)
• AQ4280 A/B/C : FC/PC, SC/PC, ST/PC
• - Rubber protector to prevent damage when dropped
• - Carrying pouch to house unit and connector adapters

 

YOKOGAWA AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA TESTER DIGITAL IMPAMANTARE EY200 (DIGITAL)

• 2P Test leads (for simplified measurement) has a structure that both the safety alligator clip and the test probe are available
• Warns when earth resistance of auxiliary earth spikes exceeds the permissible limit
• Convenient carrying soft bag for accessories etc.