Politici de confidentialitate
Date GDPR Termeni utilizare Politica cookies Confidentialitate Livrare si plata Cum comanzi?
Descriere
|
Display (LCD, Digital Counts) |
1999 |
|
AC Current Accuracy (200A Reference) |
1.5+6(50/60Hz) |
|
AC Current Accuracy (600A Reference) |
1.0+3(50/60Hz) |
|
AC Voltage Accuracy (200V/600V Reference) |
1.0+2(50/60Hz) |
|
Resistance Accuracy (200O reference) |
1.2+4, Beeps at below 30O (continuity check) |
|
Method of detection |
Mean Value |
|
Response Time |
Approx. 1 seconds (approx. 2 seconds on resistance range) |
|
Range Switching |
Manual-range |
|
Data hold |
On all range |
|
Operating temperature and humidity |
-10-50°C. (no condensation) |
|
Influence of external magnetic field |
2A or less at 400A/m |
|
Influence of conductor position |
± 2% or less |
|
Safety Standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
600Vrms or less |
|
Withstanding voltage |
5.55kV AC for one minute |
|
Power Supply |
6F22(006P)9Vx1 or 6LR61x2 |
|
Battery Life1 |
200 hours |
|
Consumed current |
Approx. 2mA |
|
Auto power-off |
Approx. 10 minutes |
|
Diameter of measurable conductor |
30mm at maximum |
|
Dimensions |
Approx. 93(W)x210(H)x40(D)mm |
|
Weight (Approx.) |
400g |
|
Accessories |
Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL130), batteries |
|
Order Notes |
Each item selected MUST be ordered as a separate line item. |
|
Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
Alte produse YOKOGAWA
|
YOKOGAWA 2553A PRECISION DC CALIBRATOR
• Digital Display of Output |
|
YOKOGAWA AQ1100 SET TESTARE PIERDERI PE FIBRA OPTICA
• 5.7 inch color LCD for easy viewing |
|
YOKOGAWA MINI CLAMP-ON TESTER CL120 (200A)
• Exclusive model for AC current measurement with current ranges up to 200A |
|
YOKOGAWA TESTER ANALOGIC SCURGERI CURENTI 322610 (ANALOG)
• ± 2.5% full scale accuracy |
|
YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR
• Frequency range: Sine wave 0.01 µHz to 30 MHz |
|
YOKOGAWA AQ2170 SERIES PORTABLE OPTICAL POWER METER (SIMPLE & COMPACT)
• Two versions of Power Meters to suit test application |
|
YOKOGAWA - WT300E POWERMETRU DIGITAL
• Fast display and data update rate: The fast display and a maximum data update rate of 100ms on the WT300E series, offers a short tact time in testing procedures. |
|
YOKOGAWA AQ4280 SURSA OPTICA PORTABILA
• - SC, FC or other connector adapter |
|
YOKOGAWA AQ2200-651 SG MODULE
• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz |
|
YOKOGAWA TESTER DIGITAL IMPAMANTARE EY200 (DIGITAL)
• 2P Test leads (for simplified measurement) has a structure that both the safety alligator clip and the test probe are available |