Seba Teleflex LV Monitor Cable fault location system with monitoring Megger

Code: Seba-KMT Megger Teleflex-LV Monitor


 

Datasheet PDF, 0.8 Mb
 

Description

Teleflex LV Monitor

Cable-monitor and fault location system

 

Benefits

  • Fault location on live low voltage cables
  • 3 phase cable monitor for a permanent check of current and voltage
  • GSM remote controlled system

 

 

Description

The Telefl ex LV Monitor has been designed for the location

of all types of low voltage cable faults but especially the

diffi cult and troublesome intermittent faults. It can be

controlled locally from a portable PC by blue tooth or

remotely over a telephone channel (GSM).

Unlike portable available TDR fault locators, the Telefl ex LV

Monitor is connected simultaneously to all 3 phases of a

live LV cable to allow the local or remote operator to perform

TDR testing on any combination of phases. Power for

the Telefl ex LV Monitor is taken through the 3 phase test

lead and the unit requires at least 1 phase to be energised.

The Telefl ex LV Monitor includes a 4 channel transient

recorder (3 voltages and 1 current) which is used to

acquire information about the exact nature and behaviour

of inter-mittent faults. The signals acquired by the transient

recorder are also used to detect "trigger" conditions for the

TDR system based on voltage distortion and/or overcurrent.

Recordings from 2 units can be used for fault

location by transient travelling waves using a special synchronising

feature.

By providing total control from a remote location the Telefl

ex LV Monitor can be connected to a faulty cable by fi eld

staff who are not necessarily familiar with the analysis of

TDR waveforms - the expertise in adjustment and interpretation

being provided by a centrally located specialist. This

becomes particularly benefi cial when the equipment has to

be left on-site awaiting the (re)-occurrence of an intermittent

fault.

 

Salient features

  • TDR based three phase fault locating system
  • Location of permanent, transient and intermittent faults
  • Application on live low voltage cables
  • Three phase voltage monitor
  • Variable trigger conditions for voltage distortion and/or over current
  • Data storage for 20 events
  • Bluetooth and GSM remote control
  • Easy to use operation software
  • Safe connection with heavy duty fused test leads
 

Standard accessories

Scope of delivery

Telefl ex LV Monitor

3 phase fused test lead, CT clamp, GSM antenna

CD with Software and user manual

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

SEBA KMT HPA 100 AC HPA 130 DC BURNDOWN HIGH VOLTAGE TESTING

• Powerful test- and burning system
• Continuous testing with AC voltages up to 100 kVrms at 5 kVA
• Own noise-level below 1 pC
• Built-in overcurrent protection
• DC testing up to 130 kV with optional rectifier

 

SEBA KMT VM-810 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Signal "jumps over" insulating pipe sleeves

 

SEBA DIGIFLEX COM REFLECTOMETER FAULT LOCATING ON METALLIC TELECOMM LINES, COAXIAL AND POWER CABLES

• Measuring range from 5 m up to 30 km
• Line comparison with 2 measuring inputs
• High resolution in the near and far range
• Weatherproof case
• Solid housing for rugged fi eld use

 

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA TELEFLEX T3060 SINGLE-PHASE POWER CABLE REFLECTOMETER T 3060

• Range 8 km, 64 km (for ICE and Decay only)
• Fully equipped reflectometer with cursor, gain, and range adjustment
• High-contrast 5.7’’ TFT color display (640 x 480 pixel), with LED backlight
• Single-phase ARM input with ICE, Decay and Trigger
• AC or battery operated (up to 3 hours battery life)

 

SEBA KMT ESG NT PINPOINTING EARTH FAULT LOCATOR IN SHEATH OF UNDERGROUND CABLES

• high accuracy pinpointing of a sheath fault
• Automatic adaptation to voltage level
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• High-contrast color display

 

SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY

• simplified version of the standard VLF test
• Easy to operate
• Configurable test sequences
• Compact, rugged and lightweight design
• AC, DC and sheath testing in one single system
• Reporting via USB or Winkis

 

SEBA DIGIPHONE+ SURGE WAVE RECEIVER FOR ACOUSTIC AND ELECTROMAGNETIC FAULT PINPOINTING IN CABLES

• Perfect acoustic quality and noise immunity
• Automatic mute function to protect your ears
• Bright, transflective sun readable display
• Easiest handling with automatic adjustment
• Earphone volume limitation to 84 dB(A)