Seba Teleflex LV Monitor Cable fault location system with monitoring Megger

Code: Seba-KMT Megger Teleflex-LV Monitor


 

Datasheet PDF, 0.8 Mb
 

Description

Teleflex LV Monitor

Cable-monitor and fault location system

 

Benefits

  • Fault location on live low voltage cables
  • 3 phase cable monitor for a permanent check of current and voltage
  • GSM remote controlled system

 

 

Description

The Telefl ex LV Monitor has been designed for the location

of all types of low voltage cable faults but especially the

diffi cult and troublesome intermittent faults. It can be

controlled locally from a portable PC by blue tooth or

remotely over a telephone channel (GSM).

Unlike portable available TDR fault locators, the Telefl ex LV

Monitor is connected simultaneously to all 3 phases of a

live LV cable to allow the local or remote operator to perform

TDR testing on any combination of phases. Power for

the Telefl ex LV Monitor is taken through the 3 phase test

lead and the unit requires at least 1 phase to be energised.

The Telefl ex LV Monitor includes a 4 channel transient

recorder (3 voltages and 1 current) which is used to

acquire information about the exact nature and behaviour

of inter-mittent faults. The signals acquired by the transient

recorder are also used to detect "trigger" conditions for the

TDR system based on voltage distortion and/or overcurrent.

Recordings from 2 units can be used for fault

location by transient travelling waves using a special synchronising

feature.

By providing total control from a remote location the Telefl

ex LV Monitor can be connected to a faulty cable by fi eld

staff who are not necessarily familiar with the analysis of

TDR waveforms - the expertise in adjustment and interpretation

being provided by a centrally located specialist. This

becomes particularly benefi cial when the equipment has to

be left on-site awaiting the (re)-occurrence of an intermittent

fault.

 

Salient features

  • TDR based three phase fault locating system
  • Location of permanent, transient and intermittent faults
  • Application on live low voltage cables
  • Three phase voltage monitor
  • Variable trigger conditions for voltage distortion and/or over current
  • Data storage for 20 events
  • Bluetooth and GSM remote control
  • Easy to use operation software
  • Safe connection with heavy duty fused test leads
 

Standard accessories

Scope of delivery

Telefl ex LV Monitor

3 phase fused test lead, CT clamp, GSM antenna

CD with Software and user manual

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT EASYLOC CAM LOCATION SYSTEM FOR LOCATION AND DEPTH MEASUREMENT OF SEWER TV CAMERAS

• 3 active frequencies (512 Hz, 640 Hz und 33 kHz)
• depth measurement at the push of a button
• Maximum marker to mark the strongest signal
• optional: Carry Bag - for easy and safe transport of Easyloc Cam
• optional: Pipeline sonde - for location non-metallic pipes

 

SEBA KMT KMK 8 COMMUNICATIONS NETWORK CABLE TESTER

• Integrated Reflectometer (TDR)
• Active bridge for high precision R and C measurements and DC and AC fault location
• Measurement by Graaf method in connection with an active slave at the far end
• Passive Wheatstone bridge for R and C measurements and DC and AC fault location
• Test Systems for Pre-measurement, Quick test and Quality testing
• Measurement of interference voltages
• Warning and information system
• Remote control for the operation of the electronic far end loop control switch

 

SEBA KMT VFL SINUS 54KV SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Single-button operation "easyGo"
• Continuous duty cycle
• Integrated safety system
• Suitable for diagnosing 45 kV rated cables

 

SEBA SFX 5-1000 SPG 5-1000 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• ICEplus for the easy and reliable fault prelocation without interference from branches
• High surge energy for pinpointing
• Compact and lightweight construction
• Testing up to 5 kV
• Automatic detection of the breakdown voltage
• Pinpointing with the integrated surge generator 0 … 2 / 4 kV 1000 J
• Pulsed DC for sheath fault pinpointing

 

SEBA KMT VFL CR-20 VERY LOW FREQUENCY CABLE TESTING SYSTEM

• VLF Test System 20 kV
• high test capacity of 3 µF permits the simultaneous testing of all three phases
• method is officially recommended by the two VDE Standards 0276-620 and 0276-621
• VLF is the most economic method for testing PE and XLPE cables

 

SEBA KMT VM-850 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Classic design, compact and light

 

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA KMT VFL CR-28..60 VLF TEST SYSTEMS FOR MEDIUM VOLTAGE CABLE TESTING

• VLF CR-28 up to cable series 15 kV
• VLF CR-40 up to cable series 23 kV
• VLF CR-60 up to cable series 35 kV
• VLF, DC and sheath fault testing in one device
• Portable thanks to two-part construction
• High test capacitance
• Integrated discharge system
• Reporting

 

SEBA KMT GEOLUX GL 660-1 EARTH FAULT LOCATOR FOR FAULT LOCATION IN ISOLATED, EARTH FREE SYSTEMS

• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to

 

SEBA KMT TAN DELTA CABLE CONDITION DIAGNOSIS SYSTEM

• Very accurate measurement
• Optional leakage current correction
• High wireless range
• Measurement at high voltage potential
• Light and portable