Seba KMT HVB-10 10kV Cable Fault Location, Steath Testing and Pinpointing Megger HVB10

Code: Seba-KMT HVB-10 Megger HVB10


 

Datasheet PDF, 0.71 Mb
 

Description

HVB 10 - unrivalled performance.

 

Output voltage 0 … 10 kV DC, bi-polar

Output current 200 mA @ 0.5 … 1.5 kV, 60 mA @ 5 kV, 30 mA @ 10 kV

 

SebaKMT’s HVB 10 is a highly accurate high-voltage bridge designed to locate cable and sheath faults, perform sheath testing, and pinpoint sheath faults, especially suited also for long HV cables.

With its top resolution, intermittent fault detetion function, and load adaptation for faster cable charging, the HVB 10 is an indispensable tool for all utilities that want to reduce downtime and facilitate repair of power and for example pilot and communication cables.

 

Benefits:

  • Automatic test sequence
  • Bi-polar prelocation for the elimination of external influences
  • Detection and indication of wrong connections
  • Touchscreen and rotary encoder
  • Only one HV connection cable
  • Completely independent of the parameters of auxiliary lines
 

Standard accessories

HVB 10, high-voltage measuring bridge 10 kV

USB-drive with software EasyProt

KST 10, bag black

Cable set for HVB 10

6 clamps

Manual

 

Recommended options

Connection set for HV armatures

 

More products SEBAKMT

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT PVS-100 PHASE IDENTIFICATION TESTER FOR CABLE SELECTION

• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES

• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification


SEBA KMT T22/1 AC HIGH VOLTAGE TESTING SYSTEM

• Compact and lightweight
• Continuous testing with AC voltages up to 75 kVrms at 1 kVA
• Expandable with a second transformer for testing up to 150 kVrms
• Built-in overload protection
• DC testing up to 80 kV with optional rectifier

 

SEBA KMT VM-850 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Classic design, compact and light

 

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND

• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material