Seba KMT VM-880 Ferrous Metal Locator, Burried and Hidden Assets

Code: Seba-KMT VM-880


 

Datasheet PDF, 0.21 Mb
     

Description

VM-880

The VM-880 is the latest generation of the ever popular 880 ferrous metal locator. Enhancing existing features and adding new, it incorporates the following to enable fast location of buried or hidden assets:

  • Excellent sensitivity
  • Lightweight, just 0.7 kg
  • Improved ergonomics for comfort during prolonged usage
  • Up to 26 hrs battery life from just 2 x AA (LR6) cells
  • Ultra strong, submersible carbon fiber antenna tube
  • Dot matrix LCD with backlight
  • Audio and visual signal strength indicators
  • Field polarity indicator
  • Continuous battery level indication
  • One touch auto sensitivity control with manual incremental control
  • 50/60Hz proximity warning
  • Unique screen invertion feature to aid pinpointing
  • Soft carry bag supplied as standard
 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA SWG 500 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG500

• Voltage Ranges : 0..2.5kV / 5kV / 10kV ; 0..4kV / 8kV / 16kV
• Energy : 195J ; 500Joules
• MAx Current Imax : 185mA ; 300mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT MMG 10 CABLE SHEATH TESTER

• Adjustable current limiter
• Easy and powerful testing of cable jackets
• Pulsed output voltage for sheath fault pinpointing
• Burning of cable faults

 

SEBA DIGIFLEX COM REFLECTOMETER FAULT LOCATING ON METALLIC TELECOMM LINES, COAXIAL AND POWER CABLES

• Measuring range from 5 m up to 30 km
• Line comparison with 2 measuring inputs
• High resolution in the near and far range
• Weatherproof case
• Solid housing for rugged fi eld use

 

SEBA KMT VFL SINUS 45KV SINE WAVE CABLE TEST SYSTEMS

• VLF sine wave 45 kV with integrated tanDelta
• compact, robust, and portable
• high-performance test and diagnostic system for medium voltage cables
• Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
• Automatically adjusts the test frequency to the cable length
• Eliminates hazards to the user and guarantees limited damage to the cable
• Easy field operation with no need for external computer

 

SEBA KMT GEOLUX GL 660-1 EARTH FAULT LOCATOR FOR FAULT LOCATION IN ISOLATED, EARTH FREE SYSTEMS

• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT VIVAX METROTECH VLOC2 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Carbon-reinforced plastic housing
• Protection class IP 54 for use in any weather conditions
• Colour display
• High-speed processor
• Several location modes with orientation using a compass
• A large number of available frequencies
• Depth/amperage at the press of a button or sustained

 

SEBA KMT VCAM LSR SEWER PIPELINE VIDEO INSPECTION CAMERA

• Flexibility, allowing multiple uses
• 3 camera head options
• Recording of the video via the VIDEO OUT
• Integrated distance counter and 640 Hz sonde
• Integrated rechargeables
• Expandable, with flex rod incorporating 9 or 11 mm diameter camera head

 

SEBA KMT HPA35 HPA50 HPA58 HPA78 AC HIGH VOLTAGE HIPOT TESTING WITHSTANDING

• HPA 35, AC testing up to 35 kVrms
• HPA 50 / 58 AC testing up to 50 / 58 kVrms
• HPA 78, AC testing up to 78 kVrms

 

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km