• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing
• High resolution of 1 mΩ, ideal for large earth systems
• Versatile tests modes
• High accuracy for earth/ground electrode grid and soil resistivity tests
• Rechargeable battery power that can last all day with a fast re-charge (up to 10 hours)
• Robust instrument with IP65 protection
• Automatic test frequency selection, with filters and high current features
• Diagnostic trace display
• Data storage
• Large colour display that shows numeric and graphical results
• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity • Individual temperature correction (ITC) of tan delta/power factor and oil conductivity • 40% faster measurements with the new IDAX 5.0 SW • Reliable measurements in high-interference environments • Multi-function test set for transformer measurements
• used for battery systems ranging from 12 to 250 V • Batteries can be tested "in service" • Unit adjusts to include load currents in the test parameters • User adjustable alarm and shutdown points to avoid excessive discharge • Easily expandable for larger battery banks using TXL extra load units (option) • Computerized test operation using TorkelWin software (option)
• 2, 3 and 4 point testing • Stakeless (clamp-on) testing capability • ART (Attached Rod Technique) capability • Multiple, user selectable test frequencies • Resistance measurement range to 200 kO • IP54 rated • Warning indicators prevent test failure • Simple one button operation • Included leads, stakes, calibration certificate and rugged carry case
• Designed for rugged field use • 0 to 100 Amp output current • Suitable for testing many different types of relays such as power, voltage and current • Easy to operate
• Test voltages : 60 kV, 80 kV and 100 kV • Laboratory instruments for measuring insulating oil breakdown voltage • Lock in precision - oil vessel with lockable adjustment • Bright 3.5" colour display • Suitable for mineral, ester and silicon oils • Trip detection circuit with direct measurement of voltage and current • Ultra fast (< 10 µs) HV switch off time
• current outputs, higher amps (3 x 15 A + 3 x 35 A), VA or compliance voltage. • test differential relays with 6 currents, or virtually any single or 3-phase relay • For secondary testing of protection relays • Can be used stand-alone or with a PC • Flexble, can test many relay types • Lightweight and portable • Greatest possible precision