• Insulation testing to 1000 MO
• Continuity testing at 200 mA down to 0.01 O
• Live circuit warning (voltage display) and test inhibit
• Digital/Analogue display
• TDR20000/2P can perform single or dual channel measurements on a wide range of metallic cables • dead or Live cables to CATIII 300V Phase to earth or 415V phase to phase can be tested.
• Determines health of lead-acid cells up to 2000 Ah • On-line testing with Pass/Warning/Fail calculations • Measures impedance, interconnection resistance and cell voltage • Windows CE operating system with 32 MB of memory • Measures float and ripple currents • Includes PowerDB LITE Management Software
• Modular based design - user configurable TM1800 from nine different modules • Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis • Dual ground testing using DCM module - increased safety with both sides of breaker grounded • Fast and easy testing - Select-Connect-Inspect workflow and high level user interface • Graphical results for quick interpretation - timing and motion measurements, coil currents • USB and Ethernet communication interface - for quick back up, LAN connection and printer options • CABA Win - for advanced data analysis, database interface and common test data archive
• Reliable results in noisy substations
• Accurate testing with RE>Act™
• Remote control for safer, easier testing
• PI Predictor™ cuts test time in half
• Full diagnostic suite with PDC capability
• Reliable testing of IEC61850 relays using a conventional relay test set • Separate Ethernet ports for the substation LAN and the controlling PC forming a Safe Substation Bus Access Point • Seamless interaction between SCL GOOSE and GOOSE "sniffing" • GOOSE merge - SCL GOOSE vs captured GOOSE for network troubleshooting and SCD file validation at FAT • Stand alone functionality - Download a configuration and run
• minimum resolution of 0.1 m and a 5 km maximum range • Simple operation. • AUTO selection of gain and pulse width. • Ultra fast pulse for near end fault identification. • Trace HOLD feature. • IP54 rating offers real life working. • Designed for use on all metallic cable pairs.
• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Up to 5000 A output current
• Two units, each of about 20 kg, makes it easier to carry
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result
• Full autoranging for measuring the length of power, telephony, CATV and LAN cables, provides distance to an open or short. • Extra large, high resolution backlit LCD. • Automatic output impedance control of 25, 50, 75, 100, 125 or 150 ohms. • User-friendly menu on screen operation. • Cable length calibration function. • Internal library of 39 standard cable types.
• Insulation testing up to 2.5 kV and 200 GΩ range in a handheld instrument
• Guard terminal for high resistance accuracy
• Adjustable insulation test voltage from 50 V to 2500 V
• Stabilised insulation test voltage