Circuit Breaker Tester Retrofit Megger ½ DDA1600

Code: Circuit Breaker Tester Retrofit Megger � DDA1600


 

Datasheet PDF, 0.14 Mb

Description

Model DDA-1600 is ideal for testing low-voltage breakers rated to 1600-ampere frame size. Incorporating the new Model DDA-1 Digital Data Acquisition Instrumentation and Control System, it provides increased control of output current and high accuracy metering of the breaker under test. A full line of other DDA test sets is available to meet all of your high-current, primary injection testing needs through 6000-ampere frame size.

 

Features:

  • Digital signal processing technology
  • Variable firing angle and pulse duration
  • Modular, portable design
  • Complies with NEMA AB-4 Test Guidelines
 

More products MEGGER

EARTH LEAKAGE CLAMPMETER MEGGER - DCM305E

• 0.001 mA resolution
• 
• Up to 100 A range for standard AC current measurements
• TRMS reading
• Low pass filter to aid stability of readings

 

MEGGER MFT-X1 MULTIFUNCTION LOW VOLTAGE ELECTRICAL INSTALLATION TESTER

• Patented Confidence Meter™ for True Loop™ testing
• Easy certificate generation and reporting
• User upgradeable operating system
• Intuitive interface for ease of use
• Comprehensive EV Testing Capability

 

UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER PS-9130 AND PS-9160

• Proven power train
• Rugged instrumentation and controls
• Direct connection of draw-out type breakers
• Integral clock/calendar
• Easy-to-read display

 

MEGGER S1-1568/2 EXPERT 15KV INSULATION RESISTANCE MEGOHMMETER

• Reliable results in noisy substations
• Accurate testing with RE>Act™
• Remote control for safer, easier testing
• PI Predictor™ cuts test time in half
• Full diagnostic suite with PDC capability

 

MEGGER TM1700 CIRCUIT BREAKER ANALYZER TM1710 TM1720 TM1740 TM1750 TM1760

• Provides reliable and accurate test results in noisy high voltage substations
• Four standard models. Full stand-alone functionality or data acquisition models without user interface.
• Fast and safer with DualGround™ testing, both sides of breaker grounded
• On-screen assistance with connection diagrams and test template Wizard
• All models can be controlled via computer

 

MEGGER DLRO200 DUCTOR MICRO-OHMMETER 200A 6220-755

• Small and weighs less than 15kg
• Test currents from 10 A to 200 A d.c.
• 0.1 µO best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 5m test leads and download software

 

MEGGER MTK310 MTK320 MTK330 ELECTRICAL INSTALLATION TEST KITS

• Three kit options available: Insulation, continuity, earth loop, RCD testing
• MTK310: Standard electrical test kit
• MTK320: Advanced electrical test kit
• MTK330: Result storage and downloading test kit
• Rubber armoured instruments
• Weatherproof IP54
• Test leads included
• Calibration certificates included
• 3 year warranty

 

MEGGER TTR300 TTR310 TTR330 THREE-PHASE TRANSFORMER TURNS RATIO METER

• Stand-alone or remote-control operation
• Accurately measures ratio, phase deviation and excitation current
• Field upgradeable without compromise to calibration
• Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
• Works in the presence of high interference/high voltage
• Highest ratio measurement (45,000:1); highest accuracy (0.1%)
• Displays % error vs. name plate with pass/fail limits

 

MICROPROCESSOR-BASED CIRCUIT BREAKER TEST SETS MEGGER PS-9116

• Portable, three piece chassis
• Tests wide range of air-frame breakers
• Test result printout capability

 

MEGGER DELTA4110 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA4000

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design