Description

  • RE>Act mode enhanced accuracy and safety
  • PI predictor function (PIp)
  • Measures up to 20 TΩ
  • Up to 3 mA noise rejection
  • Safety rated up to CAT IV 1000 V to 3000 m
  • Unique dual-case design – additional user protection
  • Operates from battery or AC mains supply
  • Rapid charge Li-ion battery

DESCRIPTION
The Megger range of 5, 10 and 15 kV insulation testers
are known worldwide for their rugged dependability,
long service life and accurate, reliable measurements.
The extensive range of models means that there will
always be a perfect match for your requirements. One
common feature across the whole range is the Megger,
‘no compromise’ approach to safety. The Megger level
of safety will always go further than simply complying
with the relevant safety standards.
Another common feature is the intuitive colour custom
display, with its ability to work in extreme environments
and unbeatable viewing angle.
The range starts with the MIT (Megger Insulation Tester)
models. These instruments provide an excellent level of
noise immunity, test performance, and safety.
For customers requiring higher capacitance charge
rates (testing long cables), working in electrically noisy
environments (e.g. transmission voltages), remote
operation, or data storage, the S1 models are the ideal
solution.
Once the best level has been selected, the only remaining
choice is the maximum test voltage required.
The Essential models come in either 5 kV or 10 kV,
whilst Advanced and Expert come in either 5, 10 or
15 kV instruments.
Please see the selection chart on page 2 of this data
sheet for more detailed information on the differentiating
features across the range.
 

Standard accessories

Description Part number
MIT515/2-UK ESSENTIAL 5kV IRT PIP 1016-079
MIT515/2-EU ESSENTIAL 5kV IRT PIP 1016-080
MIT515/2-US ESSENTIAL 5kV IRT PIP 1016-081
MIT515/2-AU ESSENTIAL 5kV IRT PIP 1016-082
MIT515/2-CN ESSENTIAL 5kV IRT PIP 1016-083
MIT515/2-BR ESSENTIAL 5kV IRT PIP 1016-621
MIT1015-UK ESSENTIAL 10kV IRT PIP 1016-089
MIT1015-EU ESSENTIAL 10kV IRT PIP 1016-090
MIT1015-US ESSENTIAL 10kV IRT PIP 1016-091
MIT1015-AU ESSENTIAL 10kV IRT PIP 1016-092
MIT1015-CN ESSENTIAL 10kV IRT PIP 1016-093
MIT1015-BR ESSENTIAL 10kV IRT PIP 1016-623

cluded accessories
Power lead 1008-017
Calibration certificate
Lead sets
Lead set 3kV 3 x 3 m, with medium clips 1008-022
Lead set HV 3 x 3 m, with medium and large clips
(MIT1015 only) 1002-534
1 kV test lead sets
Fused test probe and clip lead set 1002-913
Control circuit test set 6220-822


 

Recommended options

OPTIONAL HV TEST LEAD SETS

HV test leads sets (MIT515/2, MIT1015 only)
These test leads may also be supplied in non-standard lengths to suit
a particular application / requirement. Contact Megger
for a quotation, minimum order quantities may apply.
3 x 3 m with large clips (MIT1015 only) 1002-534
3 x 5 m with large insulated clips 1002-645
3 x 8 m with large insulated clips 1002-646
3 x 10 m with large insulated clips 1002-647
3 x 15 m with large insulated clips 1002-648
3 x 3 m with medium clips 1008-002
3 x 5 m with medium insulated clips 1002-641
3 x 8 m with medium insulated clips 1002-642
3 x 10 m with medium insulated clips 1002-643
3 x 15 m with medium insulated clips 1002-644

Screened HV test lead sets (MIT515/2, MIT1015 only)
1 x 15 m, with 5 kV screened uninsulated small clips 6311-080
3 m, 10 kV screened uninsulated small clips 6220-834
10 m, 10 kV screened uninsulated small clips 6220-861
15 m, 10 kV screened uninsulated small clips 6220-833
Other
CB101 5 kV Calibration Box 6311-077
UKAS calibration certificate 1000-047
 

More products MEGGER

MEGGER SMRT33 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER MIT1025/2 10KV INSULATING RESISTANCE MEGOMETER

• Diagnostic testing with full test suite
• PI Predictor™ cuts test time in half
• Accurate testing with RE>Act™
• Built-in storage and easy data export
• Designed for safe testing in the field

 

MEGGER MIT400/2 MIT410/2 MIT420/2 MIT430/2 CAT IV INSULATION TESTER WITH 1000V

• nsulation testing up to 1000 V and 200 GΩ range
• Stabilised insulation test voltage (New)
• Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New)
• 600 V T RMS AC and DC voltage measurement

 

POCKET SIZED INSULATION AND CONTINUITY TESTERS MEGGER - MIT200 SERIES

• Insulation testing to 1000 MO
• Continuity testing at 200 mA down to 0.01 O
• Live circuit warning (voltage display) and test inhibit
• Digital/Analogue display

 

MEGGER TTR100 TRANSFORMER TURNS RATIO METER, PHASE DISPLACEMENT, VECTOR GROUP, POLARITY

• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity
• Fully automatic; fast; easy-to-use; handheld; robust; lightweight
• Battery powered with power-saving and shutdown function
• Alphanumeric keyboard
• RS232 for data transfer and printing
• Stores 200 test results and 100 user-defined transformer test settings

 

MEGGER TORKEL 820 BS-49092 TELECOM BATTERY LOAD DISCHARGE TESTER PROGRAMMA

• Combines efficiency with portability
• Batteries can be tested "in service"
• Discharge 24 and 48 V batteries at a current of 270 A
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current.

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

SINGLE PHASE HAND CRANKED TRANSFORMER TURNS RATIO TESTER MEGGER - TTR550005B

• Used for testing single phase power and distribution transformers
• Design based on precision bridge measuring technique
• Unmatched accuracy (½0.1%) in a portable design

 

MEGGER GOOSER IEC 61850 RELAY TESTER

• Reliable testing of IEC61850 relays using a conventional relay test set
• Separate Ethernet ports for the substation LAN and the controlling PC forming a Safe Substation Bus Access Point
• Seamless interaction between SCL GOOSE and GOOSE "sniffing"
• GOOSE merge - SCL GOOSE vs captured GOOSE for network troubleshooting and SCD file validation at FAT
• Stand alone functionality - Download a configuration and run

 

MEGGER PAT120 PAT150 PAT150 ELECTRICAL INSTALLATIONS TESTER FOR CONTINUITY, INSULATION, LEAKAGE AND TOUCH CURRENT TEST

• Simple tick or cross, pass or fail indication plus measurement
• Tough, rubber armoured with built-in front cover, hardened, scratch-proof display window
• Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices
• Testing portable and fixed electrical equipment
• 10 mA and 30 mA portable RCD lead testing (PAT150)
• Adjustable PASS test limits (PAT150)