Megger CDAX-605 capacitance and dissipation factor measurement instrument CDAX605 AI-19090

Code: Megger CDAX-605 AI-19090 CDAX605


 

Datasheet PDF, 0.47 Mb
 

Description

• High accuracy and wide measurement range
? Automatic measurement process
? Measures capacitive, resistive or inductive test objects
? High accuracy ratio measurements
? Works with any standard capacitor or resistor value without any recalculations
? All standard UST and GST configurations

 

CDAX 605 is a capacitance and dissipation factor test set to be used with an external power source/generator. It is a precision instrument using a combination of bridge and direct (vector) measurements and is capable of measuring capacitive, resistive and inductive loads.

CDAX 605 is designed for laboratory, production line or field testing of electrical equipment insulation and insulating materials as well as e.g. calibration of CCVTs and other ratio devices. A test set with unique high accuracy for the most demanding applications.

 

Standard accessories

CDAX 605 AI-19090

Included accessories

Mains cable

Ground cable

Ethernet cable

CDAX Control (PC SW)

Transport case

User’s Manual

 

Recommended options

Optional accessories

5 A measuring cables

6 m (20 ft) with one UHF connector and one open end GC-30410

 

5 A measuring cables

18 m (60 ft) with one UHF connector and one open end GC-30420

Other cables/connector configurations on request

 

CDB605 Demo box for CDAX AI-90010

CRD605 High voltage resistor, 2 kV / 20 MO AI-90020

 

More products MEGGER

UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER DDA-3000 AND DDA-6000

• Model DDA-1 Digital Data Acquisition Instrumentation and Control System
• High-current output: 60,000 A for Model DDA-6000; 35,000 A for Model DDA-3000
• Digital signal processing (DSP) technology
• Variable pulse time and firing angle output current control
• Compliant with NEMA AB-4 test guidelines

 

MEGGER DLRO200 DUCTOR MICRO-OHMMETER 200A 6220-755

• Small and weighs less than 15kg
• Test currents from 10 A to 200 A d.c.
• 0.1 µO best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 5m test leads and download software

 

MEGGER TDR2000/3 1003-036 TDR2000/3P 1003-037 DUAL CHANNEL CABLE TDR

• best resolution of 0.1m the TDR2000/2 has a 20km maximum range
• Comprehensive Dual Channel capability with dual aspect display.
• AUTO set up mode for instant use.
• Ultra fast pulse for near end fault identification.
• Xpert guidance to potential fault.
• IP54 rating offers real life working.
• Designed for use on all metallic paired cables.

 

DUAL POWER MICRO-OHMMETER MEGGER DLRO10HDX DUCTER

• Interchangeable test lead terminations
• High or low output power selection for condition diagnosis
• Operates from battery or AC mains supply
• Protected to 600 V without blowing a fuse, test lead live voltage warning light

 

MEGGER MIT200 MIT210 MIT220 MIT230 INSULATION CONTINUITY TESTER

• Pocket-sized insulation and continuity testers - MIT210, MIT220, MIT230
• Insulation testing to 1000 MΩ
• Continuity testing at 200 mA down to 0.01 Ω
• Live circuit warning (voltage display) and test inhibit
• Digital/analogue display

 

AC VOLTAGE DETECTORS MEGGER - VF1 AND VF2

• Socket outlets
• Fuses
• Switches
• Wires and cables
• Circuit breakers
• Luminares

 

MEGGER DET14C 1000-761 DET24C 1000-762 EARTH RESISTANCE CLAMP METER

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

CIRCUIT BREAKER TEST SET MEGGER ½ CB-845

• Digital memory ammeter
• Digital, multirange timer
• Lightweight and portable
• High-current output
• Solid-state output initiate circuitry

 

EARTH LEAKAGE CLAMPMETER MEGGER - DCM300E

• 0.01 mA resolution
• EMC and IEC61010-2-032 compliance
• 30 mA, 300 mA, 30 A and 300 A range

 

MEGGER TORKEL 820 BS-49092 TELECOM BATTERY LOAD DISCHARGE TESTER PROGRAMMA

• Combines efficiency with portability
• Batteries can be tested "in service"
• Discharge 24 and 48 V batteries at a current of 270 A
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current.