Current Supply Unit Megger ½ CSU600A and CSU600AT

Code: Megger � CSU600A and CSU600AT


 

Datasheet PDF, 0.3 Mb

Description

These high-current supply units have two main fields of application. The first is to conduct primary tests on protective relays. A primary test shows whether all parts of the protection system are functioning together properly within the specified time limits under operating conditions. The second field of application involves conducting current tests on low-voltage circuit breakers and overcurrent devices.

 

Features:

  • Compact and rugged
  • Quick and easy to us 
  • Broad application range
  • Excellent weight/performance ratio
 

More products MEGGER

MEGGER DET4 DET4T2 DET4TD2 DET4TR2 DET4TC2 DET4TCR2 EARTH GROUND TESTER

• 2, 3 and 4 point testing
• Stakeless (clamp-on) testing capability
• ART (Attached Rod Technique) capability
• Multiple, user selectable test frequencies
• Resistance measurement range to 200 kO
• IP54 rated
• Warning indicators prevent test failure
• Simple one button operation
• Included leads, stakes, calibration certificate and rugged carry case

 

MEGGER S1-568/2 EXPERT 5000V 5KV INSULATION RESISTANCE MEGOHMMETER

• Reliable results in noisy substations
• Accurate testing with RE>Act™
• Remote control for safer, easier testing
• PI Predictor™ cuts test time in half
• Full diagnostic suite with PDC capability

 

MEGGER TPT420 VOLTAGE TESTER CATIV 1000V

• CAT IV/1000 V
• IP64 Rated
• 12 to 1000 V AC
• 12 to 1500 V DC
• Continuity test function with visual and acoustic indication
• Voltage indication with no batteries
• Single-pole voltage test
• Phase rotation indication
• Integrated torch light

 

MEGGER TDR1000/3P TDR CABLE FAULT LOCATOR

• TDR1000/3P is suitable for use on both dead or live cables
• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

MEGGER MTO210 TRANSFORMER WINDING OHMMETER

• Direct 2-channel digital reading (1 µO to 2000 O)
• DC test current up to 10 A maximum
• 0.25% measurement accuracy
• Integrated demagnetization feature
• Tests operation of on-load tap-changers
• Very fast auto safety discharge circuit

 

HAND-HELD MICRO-OHMMETER MEGGER DLRO-H200

• Safe test DualGround
• Auto range: 1 uOhm to 1000 mOhm
• Bluetooth® PC communication
• Complies with IEEE and IEC standards

 

AC VOLTAGE DETECTORS MEGGER - VF1 AND VF2

• Socket outlets
• Fuses
• Switches
• Wires and cables
• Circuit breakers
• Luminares

 

POCKET SIZED INSULATION AND CONTINUITY TESTERS MEGGER - MIT200 SERIES

• Insulation testing to 1000 MO
• Continuity testing at 200 mA down to 0.01 O
• Live circuit warning (voltage display) and test inhibit
• Digital/Analogue display

 

MEGGER MIT1015 10KV INSULATION RESISTANCE MEGOHMMETER

• RE>Act mode enhanced accuracy and safety
• PI predictor function (PIp)
• Measures up to 20 TΩ
• Up to 3 mA noise rejection

 

MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive