Primary Current Injection Test System Megger ODEN AT

Code: Megger ODEN AT


 

Datasheet PDF, 0.88 Mb

Description

This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents.

 

Features:

  • Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
  • Modular design to permit optimal user configuration of output current vs. unit size
  • Compact transport cart facilitates portability into switchgear rooms with limited space
  • Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result
 

More products MEGGER

DIGITAL MULTIMETER MEGGER - DCM340

• DC and AC current and voltage
• 600 A and 600 V
• Resistance and continuity
• 31/2 digit, 4000 count display with backlight
• High resolution digital bargraph

 

UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER DDA-3000 AND DDA-6000

• Model DDA-1 Digital Data Acquisition Instrumentation and Control System
• High-current output: 60,000 A for Model DDA-6000; 35,000 A for Model DDA-3000
• Digital signal processing (DSP) technology
• Variable pulse time and firing angle output current control
• Compliant with NEMA AB-4 test guidelines

 

MEGGER SVERKER 750 780 PROGRAMMA SINGLE PHASE RELAY TESTER

• The engineer’s toolbox for all single phase relay testing!
• Stand-alone functionality
• Rugged and reliable for field use

 

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

MEGGER DET2/3 HIGH RESOLUTION ACCURACY EARTH TEST SET

• High resolution of 1 mΩ, ideal for large earth systems
• Versatile tests modes
• High accuracy for earth/ground electrode grid and soil resistivity tests
• Rechargeable battery power that can last all day with a fast re-charge (up to 10 hours)
• Robust instrument with IP65 protection
• Automatic test frequency selection, with filters and high current features
• Diagnostic trace display
• Data storage
• Large colour display that shows numeric and graphical results

 

MEGGER IDAX-300 IDAX-350 INSULATION DIAGNOSTIC ANALYZER, TAN DELTA, POWER FACTOR

• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity
• Individual temperature correction (ITC) of tan delta/power factor and oil conductivity
• 40% faster measurements with the new IDAX 5.0 SW
• Reliable measurements in high-interference environments
• Multi-function test set for transformer measurements

 

CIRCUIT BREAKER TEST SET MEGGER ½ CB-845

• Digital memory ammeter
• Digital, multirange timer
• Lightweight and portable
• High-current output
• Solid-state output initiate circuitry

 

MEGGER SMRT33 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER MOM2 220A MICROHMMETER BD-59090 BD-59092 BD-59093

• Up to 220 A
• Battery powered
• Light weighs only 1 kg
• Safe test - DualGround™
• Auto range: 1 µO to 1000 mO
• Bluetooth® PC communication
• Complies with IEEE and IEC standards

 

DC CIRCUIT BREAKER TESTER MEGGER ½ CB360

• Capable of testing electromechanical or thermal-magnetic trip devices with dc current
• Digital timer
• High-current output up to 30,000 amperes