Primary Current Injection Test System Megger ODEN AT

Code: Megger ODEN AT


 

Datasheet PDF, 0.88 Mb

Description

This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents.

 

Features:

  • Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
  • Modular design to permit optimal user configuration of output current vs. unit size
  • Compact transport cart facilitates portability into switchgear rooms with limited space
  • Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result
 

More products MEGGER

MICRO-OHMMETER MEGGER - MOM200A

• Easy to operate
• Designed for rugged field use
• Highly flexible cable connections
• Portable and lightweight, weighs only 14 kg (31 lbs)

 

MEGGER TTR25 TRANSFORMER TURNS RATIO METER, EXCITATION CURRENT, POLARITY

• Fully automatic; fast; easy-to-use; robust; lightweight
• Battery powered
• Tests turns ratio, excitation current, and polarity
• Simple, one-button operation
• Quick-start guide on front panel
• Operator-selectable languages

 

MEGGER SMRT33 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER TDR2000/2P DUAL CHANNEL CABLE REFLECTOMETER FAULT LOCATOR

• TDR20000/2P can perform single or dual channel measurements on a wide range of metallic cables
• dead or Live cables to CATIII 300V Phase to earth or 415V phase to phase can be tested.

 

MEGGER VLOC3-PRO CABLE UTILITY TRACE LOCATOR

• Color-coded EM distortion warnings
• Offset locate modes - Vector and Plan View
• Cloud-based data warehousing
• Internal data logging
• Optional Bluetooth connectivity

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

MEGGER TTRU3 THREE-PHASE TRANSFORMER TURN RATIO TESTER

• Guaranteed accuracy ±0.05% from -20°C to +50°C
• 3Ø test voltage - up to 250V
• 3Ø step up ratio (patented)
• Phase shifting & zig-zag transformers tested
• easily and accurately
• Smallest/lightest 3Ø test set on the market
• Fast 3Ø tests - less than 10 seconds

 

ELECTRICIAN'S MULTIMETER MEGGER - AVO410

• 6000 count backlit digital display
• True RMS reading on a.c. mode
• 1000 V d.c. / 750 V a.c. ranges
• 10 A a.c. / d.c. ranges

 

MEGGER DELTA4310 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA 4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing