Electromagnetic Leakage Meter of Microwave Oven ETS-Lindgren HI-1501

Code: ETS-Lindgren HI-1501


 

Datasheet PDF, 0.09 Mb

Description

  • Three Ranges
  • Calibrated at 2450 MHz
  • Battery Operated
  • Extra sensitivity for Compliance Measurement

 

Electrical Specifications

Frequency

2450 MHz

Maximum Power Density

2.0 W/cm2

Ranges

0-2, 0-10, 0-100 mW/cm

Response Time

Fast Mode: 1 second.
Slow Mode: 2.5 secs (to 90% of Impulse Level)

 

Standard accessories

  • Fitted Carry Case
  • User Manual
 

Recommended options

  • Plastic Beaker, 600 ml.
  • Spacer Cone/Shield Kit
 

More products ETS-LINDGREN

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

BULK INJECTION CURRENT PROBES 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

HIGH GAIN CONICAL HORN ANTENNA WITH LINEAR POLARIZATION 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMI/ EMC TEST CURRENTS 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 20 HZ..5 MHZ ETS-LINDGREN 6511

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

DOUBLE-RIDGET HORN ANTENNA FOR EMC MEASUREMENTS 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 300 MHZ..6 GHZ ETS-LINDGREN 3164-06

• Frequency Minimum 300 MHz
• Frequency Maximum 6 GHz
• Connectors SMA Female (2)
• Cross Polarization Isolation >25 dB
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Linear or Circular Polarization (With Hybrid)

 

HYBRID LOG PERIODIC BROADBAND ANTENNA FOR EMC MEASUREMENTS 80 MHZ..6 GHZ ETS-LINDGREN 3149

• Frequency Minimum 80 MHz
• Frequency Maximum 6 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 750 W..200 W
• Pattern Type directional
• Polarization linear
• VSWR 6.5:1 max