High Performance Power Filters for Tempest/ EMI/ EMC test currents 16..200A ETS-Lindgren N500X

Code: ETS-Lindgren N500X


 

Datasheet PDF, 1.12 Mb

Description

  • Maximum protection in Tempest and EMPP applications
  • Highest performing commercially available power line filter
  • Over 100dB insertion loss from 10 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • Low power dissipation
  • Compact Rugged Construction
  • 100dB insertion loss from 40kHz
  • Suitable for 400Hz supplies
  • Current Range 16 to 200 Amperes

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N500X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N500X filters provide an extremely high degree of protection required to obtain maximum security.
  • N500X filters are ideal for EMC applications such as computer suites.
  • N500X filters can be used for general purpose high performance filtering.
 
 
 Electrical Specifications
 

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60Hz System per Line (Max)

Full Load Dissipation

5000

16

250

DC/50/60/400

2

1.3

20

5001

16

440/250

DC/50/60/400

4

0.65

20

5002

32

250

DC/50/60/400

2

0.3

20

5003

32

440/250

DC/50/60/400

4

0.15

20

5004

63

250

DC/50/60/400

2

0.4

48

5005

63

440/250

DC/50/60/400

4

0.2

48

5006

100

250

DC/50/60/400

2

0.3

60

5007

100

440/250

DC/50/60/400

4

0.15

60

5008

200

250

DC/50/60/400

2

0.2

80

5009

200

440/250

DC/50/60/400

4

0.1

80

  • High performance screen rooms, providing attenuation of both the incoming and outgoing mains supply lines to match the shield performance
  • Tempest applications, where the very highest degree of protection is required to obtain maximum security
  • EMP protection systems

 

Electrical Specifications

Part #

Current Max

Frequency

Max Voltage

# of Lines

Voltage Drop On Full Load in 250V 50/50Hz System/Line

DC Resistance Per Line

N2550

6 A

50/60 Hz

250 V

2

1 V

50 O

N2551

6 A

50/60 Hz

440/250 V

4

1 V

50 O

N2552

16 A

50/60 Hz

250 V

2

1 V

12 O

N2553

16 A

50/60 Hz

440/250 V

4

1 V

12 O

N2554

32 A

50/60 Hz

250 V

2

0.6 V

24 O

N2555

32 A

50/60 Hz

440/250 V

4

0.6 V

24 O

N2556

63 A

50/60 Hz

250 V

2

1.5 V

15 O

N2557

63 A

50/60 Hz

440/250 V

4

1.5 V

15 O

N2558

100 A

50/60 Hz

250 V

2

0.9 V

5 O

N2559

100 A

50/60 Hz

440/250 V

4

0.9 V

5 O

 

More products ETS-LINDGREN

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606

• Frequency Minimum 30 Hz
• Frequency Maximum 100 kHz
• Connectors Banana Jack (2) - [7605], BNC - [7606]
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

CONICAL LOG SPIRAL ANTENNA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

WIRELESS INTERFACE TEST SYSTEM FOR MOBILE PHONE TESTING IN CELLULAR COMMUNICATIONS ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

UNIVERSAL SPHERICAL DIPOLE EMI RADIATION SOURCE ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

MAGNETIC FIELD MEASUREMENT PROBE 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 300 MHZ..6 GHZ ETS-LINDGREN 3164-06

• Frequency Minimum 300 MHz
• Frequency Maximum 6 GHz
• Connectors SMA Female (2)
• Cross Polarization Isolation >25 dB
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Linear or Circular Polarization (With Hybrid)

 

EMC AND RF MICROWAVE ABSORBERS ETS-LINDGREN

• EMC Anechoic Absorber
• Ferrite Tile Absorber
• FerroSorb FS EMC Absorber
• FerroSorb PS EMC Absorber
• Ultra Broadband Microwave Absorber

 

RFI/ EMI CONTROL FILTERS FOR ALARM, DETECTION AND MONITORING SYSTEMS ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options