High Gain Conical Horn Antenna with Linear Polarization 4..26.5 GHz ETS-Lindgren 3163

Code: ETS-Lindgren 3163


 

Datasheet PDF, 0.54 Mb

Description

  • Conical Shape
  • Series Frequency Range: 4 GHz to 26.5 GHz
  • High Gain
  • Low VSWR
 

Model

Frequency Range

VSWR Ratio

(AVG)

Max Continuous Power

Impedance (Nominal)

Connectors

3163-03

4 GHz - 8 GHz

3.2:1 maximum
1.5:1 average

250 watts

50 ?

Type N (F)

3163-04

8 GHz - 12 GHz

2.5:1 maximum
1.5:1 average

250 watts

50 ?

Type N (F)

3163-05

12 GHz - 18 Ghz

2:1 maximum
1.25:1 average

200 watts

50 ?

Type N (F)

3163-06

18 GHz - 26.5 GHz

2:1 maximum
1.25:1 average

50 watts

50 ?

SMA (F)

 
 

Model

Aperture Diameter

Length (Without Mount)

Weight

3163-03

17.8 cm   (7.01 in)

60 cm   (23.62 in)

1.8 kg   ( 3.97 lb )

3163-04

10.2 cm   (4.02 in)

37 cm   (14.57 in)

0.5 kg   ( 1.10 lb )

3163-05

10.2 cm   (4.02 in)

39 cm   (15.35 in)

0.6 kg   ( 1.32 lb )

3163-06

10.2 cm   (4.02 in)

38 cm   (14.96 in)

0.5 kg   ( 1.10 lb )

 

More products ETS-LINDGREN

BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

PASSIVEELECTRIC FIELD MONOPOLE TRANSMITTING ANTENNA 1 KHZ..30 MHZ ETS-LINDGREN 3303

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Peak Power 1 W
• Polarization linear
• Switchable Two-band Transformer
• Two Year Warranty

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3112

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 800 W
• Maximum Power 2 kW

 

PROTECTION FILTERS FOR TEMPEST/ RFI/ EMI DIGITAL ANALOG DATA TRANSMISSIONS ETS-LINDGREN N2460

• Suitable for EMI and Tempest Protection
• Digital and analogue transmissions
• Tubular, flat-pack or modular design

 

RF ATTENUATION AND ELECTROMAGNETIC SHIELDING METER 8..64 MHZ ETS-LINDGREN MF-130D

• Measurement frequencies: 8 MHz, 16 MHz, 32 MHz and 64 MHz
• Makes Shielding Attenuation
• MIL-STD-285 Measurements
• NSA 65-6 Measurements
• IEEE STD-299 Measurements
• EN 50147-1 Measurements
• Stores/Downloads up to 63
• Includes Windows® Compatible Easy-To-Use, Portable Software

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BROADBAND OMNIDIRECTIONAL ANTENNA FOR SPECTRUM MONITORING 500 MHZ..18 GHZ ETS-LINDGREN 3181

• Frequency Minimum 500 MHz
• Frequency Maximum 18 GHz
• Connectors SMA (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts @ 500 MHz, 25 watts @ 18 GHz

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4