High Gain Conical Horn Antenna with Linear Polarization 4..26.5 GHz ETS-Lindgren 3163

Code: ETS-Lindgren 3163


 

Datasheet PDF, 0.54 Mb

Description

  • Conical Shape
  • Series Frequency Range: 4 GHz to 26.5 GHz
  • High Gain
  • Low VSWR
 

Model

Frequency Range

VSWR Ratio

(AVG)

Max Continuous Power

Impedance (Nominal)

Connectors

3163-03

4 GHz - 8 GHz

3.2:1 maximum
1.5:1 average

250 watts

50 ?

Type N (F)

3163-04

8 GHz - 12 GHz

2.5:1 maximum
1.5:1 average

250 watts

50 ?

Type N (F)

3163-05

12 GHz - 18 Ghz

2:1 maximum
1.25:1 average

200 watts

50 ?

Type N (F)

3163-06

18 GHz - 26.5 GHz

2:1 maximum
1.25:1 average

50 watts

50 ?

SMA (F)

 
 

Model

Aperture Diameter

Length (Without Mount)

Weight

3163-03

17.8 cm   (7.01 in)

60 cm   (23.62 in)

1.8 kg   ( 3.97 lb )

3163-04

10.2 cm   (4.02 in)

37 cm   (14.57 in)

0.5 kg   ( 1.10 lb )

3163-05

10.2 cm   (4.02 in)

39 cm   (15.35 in)

0.6 kg   ( 1.32 lb )

3163-06

10.2 cm   (4.02 in)

38 cm   (14.96 in)

0.5 kg   ( 1.10 lb )

 

More products ETS-LINDGREN

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

ACTIVE RECEIVING LOOP SHIELDED ANTENNA 1 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 10 V/m
• Connectors BNC (f)
• Dynamic Range 116 dB @ 1 MHz , 76 dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

RESONANT DIPOLE ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

DOUBLE-RIDGET HORN ANTENNA FOR EMC MEASUREMENTS 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

ELECTROMAGNETIC FIELD EMISSION METER OF ELECTRIC TRANSMISSION ELECTRIC POWER LINES ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

HYBRID LOG PERIODIC BROADBAND ANTENNA FOR EMC MEASUREMENTS 26 MHZ..3 GHZ ETS-LINDGREN 3140B

• Frequency Minimum 26 MHz
• Frequency Maximum 3 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear
• Best EMC RI Performance

 

PRECISION DIPOLE ANTENNA WITH OMNI-DIRECTIONAL EMISSIONS FOR IMMUNITY TESTING 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements