High Performance Power Filters for Tempest/ EMP applications currents 16..200A ETS-Lindgren N600X

Code: ETS-Lindgren N600X


 

Datasheet PDF, 0.64 Mb

Description

  • Suitable for 400Hz supplies
  • Compact Rugged Construction
  • Maximum Protection for EMP and Tempest applications
  • Current Range 16 to 200 Amperes
  • 100 dB Insertion Loss from 14 kHz to 40 GHz
  • Low power dissipation

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N600X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N600X filters provide an extremely high degree of protection required to obtain maximum security.
  • N600X filters are ideal for EMP applications needing to meet the most stringent NATO requirements.
  • N600X filters can be used for filtering of mains incomers entering screened room facilities.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz System Per Line (Max)

Full Load Dissipation (W)

6000

16

250

DC/50/60/400

2

1.2

35

6001

16

440/250

DC/50/60/400

4

1

45

6002

32

250

DC/50/60/400

2

1.1

70

6003

32

440/250

DC/50/60/400

4

0.75

50

6004

63

250

DC/50/60/400

2

1.3

68

6005

63

440/250

DC/50/60/400

4

0.75

155

6006

100

250

DC/50/60/400

2

0.7

135

6007

100

440/250

DC/50/60/400

4

0.5

135

6009

200

440/250

DC/50/60/400

4

1

400

 

More products ETS-LINDGREN

ELF MAGNETIC FIELD SURVEY METER 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

BULK INJECTION CURRENT PROBES 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

BICONICAL TRANSMITTING-RECEVING ANTENNA 20..200 MHZ ETS-LINDGREN 3104C

• Frequency Minimum 20 MHz
• Frequency Maximum 200 MHz
• Connectors Type N (f)
• FS-600 High Performance Hybrid Ferrite Tile Polyurethane Dielectric 200 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Pattern Type omnidirectional
• Peak Power 100 W
• Polarization linear

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3112

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 800 W
• Maximum Power 2 kW

 

BROADBAND OMNIDIRECTIONAL ANTENNA FOR SPECTRUM MONITORING 500 MHZ..18 GHZ ETS-LINDGREN 3181

• Frequency Minimum 500 MHz
• Frequency Maximum 18 GHz
• Connectors SMA (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts @ 500 MHz, 25 watts @ 18 GHz

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 2..18 GHZ ETS-LINDGREN 3164-05

• Frequency Minimum 2 GHz
• Frequency Maximum 18 GHz
• Connectors SMA Female
• Cross Polarization Isolation >24 dB
• Impedance (Nominal) 50 ?
• Maximum Power 25 W
• Pattern Type directional
• Polarization dual linear

 

BICONICAL PRECISION MEASUREMENT ANTENNA 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

BROADBAND LOG PERIODIC ARRAY ANTENNA 200 MHZ..5 GHZ ETS-LINDGREN 3147

• Frequency Minimum 200 MHz
• Frequency Maximum 5 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 80 W
• Pattern Type directional
• Peak Power 100.0 W
• VSWR 1.2:1