Code: ETS-Lindgren 95236-1/ 95242-1
Description
The probe's operating frequency range is 10 kHz to 100 MHz. This probe is most efficient from about 15 kHz to 4 MHz. The 95236-1 probe cover the low frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (10 kHz · Z MHz).
The Model 95236-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
10 kHz |
|
Frequency Maximum |
100 MHz |
|
Maximum Power |
100 W |
It enables testing to be performed which previously required the use of two separate injection probes, the ERA type 36A and 37A This is our most efficient injection device from 4 MHz to almost 600 MHz The 95242-1 probe covers the high frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (5 MHz - 400 MHz). This injection probe is also suitable for injecting the required current waveforms of MIL-STD-461D limits CS115 and CS116 (for CS116, one of our lower frequency probes is required as well). Testing to British Defense Standard DEF STA 59-41, Part 3 is also supported by this model. When necessary, our 95235-1 injection probe has larger 2.625" window diameter, but is less efficient than the 95242-1. When calibrating the Calibration Jig coupled current vs. forward power into the injection probe, the combination of 95242-1 probe and 95241-1 Jig has an excellent low VSWR.
The Model 95242-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
2 MHz |
|
Frequency Maximum |
400 MHz |
|
Maximum Power |
100 W |
More products ETS-LINDGREN
|
BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B
• Frequency Minimum 200 MHz |
|
INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702
• Wide Frequency Response (9 kHz - 70 MHz) |
|
DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3112
• Frequency Minimum 100 MHz |
|
RESONANT DIPOLE ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3121D
• Frequency Minimum 30 MHz |
|
BROADBAND OMNIDIRECTIONAL ANTENNA FOR SPECTRUM MONITORING 500 MHZ..18 GHZ ETS-LINDGREN 3181
• Frequency Minimum 500 MHz |
|
PROTECTION FILTERS FOR TEMPEST/ RFI/ EMI DIGITAL ANALOG DATA TRANSMISSIONS ETS-LINDGREN N2460
• Suitable for EMI and Tempest Protection |
|
RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230
• Standard dimenssions 600 x 500 x 500 mm |
|
HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X
• Current Rating 2 Amps |
|
QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 2..18 GHZ ETS-LINDGREN 3164-05
• Frequency Minimum 2 GHz |
|
ELECTRIC & MAGNETIC FIELD RF INDUSTRIAL COMPLIANCE TESTER 10..42 MHZ ETS-LINDGREN HI-3408
• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies |