Quad-Ridged Open Boundary Horn Antenna 100 MHz..1 GHz ETS-Lindgren 3164-01

Code: ETS-Lindgren 3164-01


 

Datasheet PDF, 0.36 Mb

Description

  • Frequency Minimum     100 MHz
  • Frequency Maximum    1 GHz
  • VSWR Ratio (AVG)    3:1 maximum
  • 1.75:1 average
  • Maximum Continuous Power    750 watts @ 100 MHz
  • 200 watts @ 1 GHz
  • Impedance (Nominal)   50 ?
  • Connectors       (2) Type N Female
  • 100 MHz - 1 GHz Frequency Range
  • Excellent Gain Characteristics
  • Dual Linearly Polarized
  • Better Than 25 dB Cross-Port Isolation
 

More products ETS-LINDGREN

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 1..18 GHZ ETS-LINDGREN 3117

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Peak Power 400 W
• Polarization linear

 

MULTI-OCTAVE PYRAMIDAL HORN ANTENNA LINEAR POLARIZED 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

VLF MAGNETIC FIELD SURVEY METER 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

BULK INJECTION CURRENT PROBES 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

BICONICAL ANTENNA FOR TESTING IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear