Trusa incercari cable 70kV DC Seba HPG 70-K

Cod: Seba-KMT HPG-70-K


 

Brosura produs PDF, 0.17 Mb

Descriere

HPG 70-K

The high voltage test set HPG 70-K from SebaKMT is a fully insulated test set for DC testing up to 70 kV. Thanks to its fully insulated design this system is ideal for stand-alone applications. The DC voltage is obtained through a bridge rectifier which ensures a very low ripple of the test voltage. Moreover the DC voltage is measured on the secondary side and therefore ensures a precise output voltage.

 

Typical application areas:

  • Testing of cables
  • Testing of switchgear
  • Testing of current-transformers
  • Testing of MV plant/ component testing

 

Key benefits:

  • Highest safety thanks to fully insulated design
  • Compact and lightweight
  • Separate control and HV-unit
  • Voltage continuously adjustable
  • Expandable with a VLF CR attachment for VLF testing on MV cables

 

 

System description

SebaKMT’s high voltage test set HPG 70-K is a fully insulated

test set for DC testing up to 70 kV. Thanks to its fully insulated

design, this system is ideal for stand-alone applications. The

DC voltage is obtained through a bridge rectifi er which

ensures a very low ripple of the test voltage. Moreover, the

DC voltage is measured on the secondary side and therefore

ensures a precise output voltage.

The high voltage test equipment HPG 70-K consists of two

parts and is used for testing of cable installations either as a

stand-alone unit or built into a module or cable test van. The

control unit HSG 1 includes a variac. Its output voltage feeds

the high voltage unit HVT 70.

The high voltage unit HVT 70-K is fully insulated. The test

voltage of 70 kV DC is drawn from a socket outlet and plug

and fed to the cable under test. For feeding of the control

voltage of 0 … 230 V AC, a multi-pole connection lead to the

control unit is supplied.

For testing of polymer insulated cables the test system can

be expanded with a VLF CR attachment. This attachment

will allow high-capacitance testing up to 54 kV at 0.1Hz.

 

Accesorii standard

Scope of delivery HPG 70-K

Control unit HSG 1

HV-unit HVT 70-K

Kabelsatz

Entladestab 75 kV

 

Scope of delivery HPG 70-K-VLF

Control unit HSW 3-VLF

HV-unit HVT 70-K

VLF attachment VLF PZ

Set of cables

Discharge rod 75 kV

 

Optiuni recomandate

 

 

Alte produse SEBAKMT

REFLECTOMETRU LOCALIZARE DEFECTE LINII COMUNICATII, COAXIALE, CABLURI ENERGIE ELECTRICA SEBA DIGIFLEX COM

• Pentru localizarea defectelor în linii de telecomunicatii de la 50 m la 30 km
• Rezolutie ridicata pe cabluri scurte sau lungi
• Afisaj dual pentru evaluarea clara a reflectogramei
• Rezolutie ridicata pâna la 2,5 cm în domeniul de 50 m
• Afisaj LCD de mari dimensiuni, cu iluminare

 

GENERATOR UNDA DE SOC PENTRU LOCALIZAREA DEFECTELOR IN CABLURI SEBA SWG 500

• Domenii tensiune : 0..2.5kV / 5kV / 10kV ; 0..4kV / 8kV / 16kV
• Energie : 195J ; 500Joul
• Curent maxim Imax : 185mA ; 300mA
• Energie de soc optimizata prin condensatoare comutabile
• ICE - Metoda cuplarii în curent(ICE = Impulse Current Equipment)
• ARM - Metoda reflexiei pe arc(metoda de reflexie cu IT)

 

IDENTIFICATOR FAZA SELECTIE CABLU DE TENSIUNE SEBA PVS 100

• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money

 

REFLECTOMETRU LOCALIZARE DEFECTE CABLURI DE ENERGIE ELECTRICA SEBA TELEFLEX VX

• Domeniu: 20 m … 1280 km
• Afisaj mare de 15", luminos si antireflexiv
• Operare usoara prin meniuri intuitive
• Tehnologie ARM2 multi-impuls
• Memorarea automata a tuturor masuratorilor
• Suporta toate metodele de prelocalizare existente
• Reglare automata si afisarea automata a capatului cablului

 

SISTEM INCERCARE SI LOCALIZARE DEFECTE CABLE SEBA SURGEFLEX SFX-32

• Încercare cu pâna la 32 kV
• Prelocalizare:
• o Masurarea impulsului reflectat
• o ARM® (Metoda reflexiei arcului)
• o Metoda cuplarii în curent 8 / 16 / 32 kV
• Ardere (modificarea defectului) pâna la 32 kV
• Localizarea traseului (optional)
• Localizare exacta: o Masurarea distantei / câmpului acustic(8 / 16 / 32 kV cu 1750 / 3500 J)
• o Localizarea defectelor de manta (0 … 5 kV cu limitare în curent)

 

PUNTE MASURA DEFECTE CABLURI RETELE COMUNICATII SEBA KMK 8

• Integrated Reflectometer (TDR)
• Active bridge for high precision R and C measurements and DC and AC fault location
• Measurement by Graaf method in connection with an active slave at the far end
• Passive Wheatstone bridge for R and C measurements and DC and AC fault location
• Test Systems for Pre-measurement, Quick test and Quality testing
• Measurement of interference voltages
• Warning and information system
• Remote control for the operation of the electronic far end loop control switch

 

SISTEM DETECTIE DESCARCARE PARTIALA SI DEFECT IZOLATIE CABLU SEBA OWTS M60

• Masurarea PD cu ajutorul DAC similar cu frecventa nominala a retelei
•  Procesare online - diagnoza complexa a PD
•  Sistem de test portabil, conceptie compacta si usoara
•  Masurare integrata a tan d

 

SISTEM INCERCARE CU INALTA TENSIUNE SEBA T26/1 T26/1A T26/1B T26/1C

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

DEFECTOSCOP PENTRU LOCALIZAREA DEFECTELOR PE CABLURI MT/JT SEBA SMART THUMP 16

• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning
• Integrated ARM and ICE Prelocation
• Easy Go - automatic sequence to proof test, pre-locate & pinpoint
• Automatic interpretation of test results
• Sunlight readable, transflective 5.7" TFT colour display
• Safe OP Check protects user from incorrect or faulty lead connections
• USB interface for trace export via USB flash drive

 

GENERATOR UNDA DE SOC PENTRU LOCALIZAREA DEFECTELOR IN CABLURI SEBA SWG 1750

• Domenii tensiune : 0.. 8kV / 0..16kV / 0..32kV
• SWG 1750C with 8 - 16 - 32 kV / 1750 J
• SWG 1750 CI with 8 - 16 - 32 kV / 1750 J, incl. leakage current measurement
• SWG 1750 C-4 with 2 - 4 kV / 1150 J and 8 - 16 - 32 kV / 1750 J