Generator Impulsuri 3a, 3b simulare tranizitorii testare EMC Automotive NoiseKen ISS-7630

Cod: NoiseKen ISS-7630


 

Descriere

  • Pulse 3a and Pulse 3b generating unit
  • A built-in 60V/30A Coupling Network allows independent operation.
  • <3.5ns rise time pulse available
  • Runs in pulse repetition frequencies sweep mode from 1 kHz to 100 kHz (ISS-7601 software required)

 

 

SPECIFICATION

 

Parameters

Specifications (Pulse 3a. 3b)

Output Voltage (Us)

Pulse 3a

- 20 ~  -350V ±10% ( -1V step)
 

Pulse 3b

20 ~  350V ±10%  (1V step)

Output Resistance (Ri)

50 ohm

Duration (td)

150ns±45ns

Rise time (tr)

Set as 5n

5ns±1.5ns (Us=±20V~±350V)

Set<3.5ns

< 3.5ns (Us=±50V~±300V)

Pulse period (t1)

10µs ~ 999µs ±10%  (1 µs step)

t4 (refer to the figures shown belown for its definition)

1ms ~ 100ms ±10% (1ms step)

t5(refer to the figures shown belown for its definition)

9ms ~ 999ms ±10% (1ms step)

Test Time

Set in min

1min ~ 999 min  ±10%  (1ms step)

Set in sec

1s ~ 999 s  ±10%  (1s step)

Circuit Breaker

Rated Current 40A

Interlock

External input:
Control at contact point or Open Collector
L Level: 0~0.4V       H level: 2V~4V

Remote control
from PC

Interface

Option: Optical Interface Unit Model: 07-00022A

Software

Option: Remote Control Software Model: ISS-7601

Compatible OS

Windows XP

DUT capacity

DC60Vmax, 30Amax

Power supply

AC100V, 110V, 120V, 200V, 220V, 240V ±10% (50/60Hz)

Operating temperature and humidity

 23°C±5°C / 25~75% (No dewing shall occur.)

Dimensions

(W) 430 X (H) 200 X (D) 522 mm
(Projections excluded)

Weight

Approx. 17kgs

Power consumption

Approx. 110VA

Standard accessories

Instruction manual
Replacement Fuse (3.16A)
Interlock plug
DC Input Cable (2m)
Output cable (0.5m)
BNC conversion adapter
50 ohm coaxial cable with BNC
GND cable
Short-circuit lead (for waveform verification

 

Alte produse NOISEKEN

GENERATOR IMPULSURI 3A, 3B SIMULARE TRANIZITORII TESTARE EMC AUTOMOTIVE NOISEKEN ISS-7630

• Pulse 3a and Pulse 3b generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• <3.5ns rise time pulse available
• Runs in pulse repetition frequencies sweep mode from 1 kHz to 100 kHz (ISS-7601 software required)


SIMULATOR FORME DE UNDA CRESTERI SI CADERI DE TENSIUNE NOISEKEN VDS-2002

• Conforming to IEC 61000-4-11
• Fully compliant with all the test generator requirements of IEC standard.
• One unit solution for dip, swell, interruption and variation tests up to 16A 290V single phase AC
• Interruption test up to 16A 125V DC (*)
• Two motor-driven transformers approach enables switching between any voltages (*)
• Preset IEC test levels 0%/40%/70%/80% plus additional 120%

 

SURSA-SIMULATOR CRESTERI/ CADERI DE TENSIUNE NOISEKEN VDS-1007/ 2007

• VDS-1007 : 1kVA Power
• VDS-2007 : 2kVA Power
• Enable to enrich EMC preliminary tests with the remote control as an AC stabilizing power source
• Enable IEC61000-4-11/13/14/28 precompliant tests
• Usable to be power source for IEC61000-3-2-2 precompliant measurement

 

SIMULATOR IMPULSURI ZGOMOT TESTARE EMC NOISEKEN INS-4020/ 4040

• INS-4020 (2kV) : 0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step
• INS-4040(4kV) : 0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step
• Automatic ramp operation for output voltage, phase angle and repetition period
• Floating output
• Coupling mode selection by plugging the supplied coaxial connector to the selected port
• Easily changeable mercury relay unit

 

SISTEM SCANARE/ MASURA EMISII RADIATII ELECTROMAGNETICE CAMP APROPIAT NOISEKEN EPS-3007

• Provides an amplitude versus frequency plot for each antenna probe position and field intensity distribution map by a single scan
• Electric and magnetic fields are separately detected
• 3D graphical representation and zoom capability for a given area
• Comparison before and after a modification or improvement
• Scanning by a single antenna probe to minimize error between each measurement point
• 3GHz maximum frequency response (option)
• Standard included three kinds of antenna probes (Probe A, Probe B and Probe C)

 

SIMULATOR DESCARCARE ELECTROSTATICA CIRCUITE SEMICONDUCTOARE ESD NOISEKEN ESS-6002/ 6008

• ESS-6002 Output voltage: 10V ~2.0kV ±10% (1V step)
• ESS-6008 Output voltage: 100V ~ 8.0 kV±10% (10V step)
• A simple probe stand and test fixture plus a pair of miniature test leads
• Narrow pitch DUT can be tested in semi-automatic manner
• Each probe has a coaxial interface with an external measuring instrument.

 

SISTEM MASURA EMISII RADIATII ELECTROMAGNETICE PLACI PCB NOISEKEN EPS-6000

• Measurable up to 8GHz in the frequency range
• 4 axes (X, Y, Z, ?) measurements with minute step minimum 0.1m realized
• Equivalent distance measurement to parts on PCBs even the heights are different
• Composite figure of photo of the measured PCB and the measurement data realized
• Rich magnetic field probes in the figures, sizes and Vertical/Horizontal directions
• Versatile display for the measurement data as 2 dimensions, 3 dimension, and equiangular line realized

 

SIMULATOR IMPULSURI ZGOMOT TESTARE EMC NOISEKEN INS-AX2

• INS-AX2-220/250 : 0.01 ~ 2.00kV±10% at 0.01kV step Pulse output voltage
• INS-AX2-420/450 : 0.01 ~ 4.00kV±10% at 0.01kV step Pulse output voltage
• Floating output
• 8 pulse widths installed: 10ns, 50ns, 100ns, 200ns, 400ns, 500ns, 800ns and 1000ns
• Internal switchable terminators
• Easily changeable and safety-interlocked outlet panel (EUT interface)
• 3 channels EUT fail input

 

SIMULATOR DESCARCARI ELECTROSTATICE ESD NOISEKEN ESS-B3011/ESS-L1611

• ESS-B3011 : 0.2 to 30.0kV
• ESS-L1611 : 0.2 to 16.0kV
• EN/IEC 61000-4-2 Ed2 Compliant (B3011/L1611)
• ISO 10605 Ed2 Compliant (B3011/L1611)
• 3 pre-checking function taking the confirmable test into the account (B3011/L1611)
• Discharge detecting function to realize the air-discharge confirmation (B3011/L1611)
• Lightest Discharge Gun in the market to lighten the continuous operation (GT-30R)

 

SIMULATOR DESCARCARI ELECTROSTATICE ESD NOISEKEN ESS-S3011

• 0.2 to 30.0kV +/-5% (30.5kV Maximum)
• 0.2 to 10kV: 0.05V step, 10.0 to 30.0kV: 0.1kV step
• EN/IEC 61000-4-2 Ed2 Compliant
• ISO 10605 Ed2 Compliant
• Pre-test
• Ten-key & Rotary knob to ease the setting
• Infra-red Remote Controller to allow remote Generator setting