Karl Fischer Moisture In Oil Test Sets Megger ½ KF875 and KF-LAB MkII

Cod: Megger KF875 KF-LAB MkII


 

Brosura produs PDF, 0.22 Mb

Descriere

Over 20 years experience has led to the development of the Megger KF875 and KF-LAB MkII Coulometric Karl Fischer Test Sets designed to determine moisture in oil, to provide highly accurate results on-site. The KF875 and KF-LAB MkII are highly portable instruments, complete with integral printer and carrying case, are easy to use and provide highly accurate results.

 

Optimized for testing insulating oils with a specific gravity of 0.875, the Megger KF875 simply requires the operator to press one button and inject a 1ml sample into the test cell. The simple ½one touch½ operation makes the KF875 so easy to use that it requires no specialist knowledge or training to use it effectively. Results are presented on the instrument display and on the integral printer in both micrograms of water and in milligrams per kilogram (parts per million, ppm).

 

The KF-LAB MkII allows the titration of samples with a range of specific gravities from 0.60 to 1.40 and also permits the use of different sample sizes. The KF-LAB MkII also has a default setting optimized for analyzing insulating oils with an SG of 0.875. This means it can be used to measure water content in a variety of different materials but is also easy to set up for transformer insulating oils.

 

Features:

  • Coulometric Karl Fischer titrimetry
  • KF875 optimized for insulating oil with an SG of 0.875, completely portable
  • KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
  • KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875
 

Alte produse MEGGER

FORK MULTIMETER MEGGER - DCM330

• 200.0 A a.c. open-jaw current measurement
• 0.1 V to 1000 V auto-ranging a.c. and d.c. voltage measurement
• 0.1 O to 20.00 MO resistance range
• Continuity buzzer

 

TESTER CURENTI REZIDUALI RCD-URI MEGGER RCDT300 RCDT310 RCDT320 RCDT330

• Testează RCD-uri standard, CC, selective şi programabile
• Testarea rampei (RCDT320/330)
• Testarea automată (de la distanţă) (RCDT320/330)
• Siguranţă trifazată

 

SMART PRIMARY INJECTION TEST SYSTEM MEGGER SPI225

• Up to 2000A output
• Smallest primary injection test system in its class
• First unit on the market to eliminate variac control
• Output current regulation
• Designed for switchgear commissioning, circuit breaker, CT commissioning, ground grid and relay testing
• Software includes thousands of circuit breaker TCC curves

 

AC VOLTAGE DETECTORS MEGGER - VF3

• Non-contact detection of AC voltage
• Automatic audible warning buzzer
• Bright red voltage indicator in tip
• Ultra bright LED torch

 

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

OHMMETRU INFASURARI TRANFORMATOARE 10A MEGGER MTO210

• Direct 2-channel digital reading (1 µO to 2000 O)
• DC test current up to 10 A maximum
• 0.25% measurement accuracy
• Integrated demagnetization feature
• Tests operation of on-load tap-changers
• Very fast auto safety discharge circuit

 

MEGOHMMETRU REZISTENTA IZOLATIE 5KV MEGGER MIT515/2

• Mod RE>Act precizie şi siguranţă îmbunătăţite
• Funcţie de predicţie PI (PIp)
• Măsoară până la 20 TΩ
• Rejecţie a zgomotului de până la 3 mA

 

TRUSA MONOFAZATA CURENT-TENSIUNE MEGGER SVERKER 750 780

• The engineer’s toolbox for all single phase relay testing!
• Stand-alone functionality
• Rugged and reliable for field use

 

TRUSA TRIFAZATA DE VERIFICARE RELEE DE PROTECTIE MEGGER SVERKER900

• The toolbox for substation 3-phase testing
• Three currents and four voltages
• Stand-alone functionality
• Rugged and reliable for field use
• Generation of 900 V and 105 A in single phase mode
• Secondary and primary testing

 

BATTERY IMPEDANCE TESTER MEGGER - BITE2 AND BITE2P

• Determines condition of lead-acid and NiCd cells up to 7000 Ah
• On-board Pass/Warning/Fail indications
• Robust, repeatable instruments
• On-line testing