  • Insulation test range: 0.1 MO to 2000 MO
  • Insulation test voltages: 500 V, 1000 V
  • Save both time and money with automatic calculation of Polarization Index and Dielectric Absorption Ratio
  • Repetitive or hard-to-reach testing is easy with the remote test probe
  • Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
  • Auto-discharge of capacitive voltage for added user protection
  • AC/DC voltage: 0.1 V to 600 V
  • 200 mA Continuity
  • Resistance: 0.01 O to 20.00 kO
 

Accesorii standard

  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation
 

Optiuni recomandate

  • TL225 Stray Voltage Adapter Test Lead Kit
  • C101 C101 Hard Case
  • C25 Soft Meter Case
  • CXT170 CXT170 Extreme Case
  • TPAK ToolPak, Meter Hanging Kit
 

Alte produse FLUKE

FLUKE 190-062 190-062/S OSCILOSCOP PORTABIL DIGITAL 2X60 MHZ

• 2-canale izolate 60MHz
• Clasa de protectie CAT III 1000 V, CAT IV 600 V
• Multimetru digital dedicat cu 5000 de numărări la modele cu două canale
• Măsurători automate avansate, energie (Vpwm, VA, W, PF) ™ timp (mAs, V/s, w/s)
• Clasa de protectie IP-51 pentru praf şi lichide pentru a rezista in medii dificile
• Porturi USB izolate

 

FLUKE 190-102 190-102/S OSCILOSCOP PORTABIL DIGITAL 2X100 MHZ

• 2-canale izolate 100MHz
• Clasa de protectie CAT III 1000 V, CAT IV 600 V
• Multimetru digital dedicat cu 5000 de numărări la modele cu două canale
• Măsurători automate avansate, energie (Vpwm, VA, W, PF) ™ timp (mAs, V/s, w/s)
• Clasa de protectie IP-51 pentru praf şi lichide pentru a rezista in medii dificile
• Porturi USB izolate

 

DETECTOR DE TENSIUNE FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC

 

KIT INREGISTRARE TENSIUNE AC LA DISTANTA FLUKE FLK-CNX V3000 KIT

• masuratori de tensiune c.a. si c.c. true-rms, la 1.000 V
• curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• Masuratori de tensiune c.a. true-RMS pâna la 1000 V
• memorie de înregistrare de pâna la 65.000 de masuratori
• CAT III 1000 V; CAT IV 600 V; IP42


CALIBRATOR DE PRESIUNE FLUKE 721

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

CLESTE AMPERMETRIC DE CURENT HVAC 600A FLUKE 902

• Designed for HVAC applications
• capacitance, DC Current (µA), and temperature measurements
• Small body and jaws

 

FLUKE II915 CAMERA ACUSTICA DETECTIE SCAPARI GAZE, DECARCARI ELECTRICE SI DEFECTE MECANICE

• Performanță îmbunătățită: Performanță îmbunătățită de detectare a scurgerilor de gaz, descărcărilor electrice È™i problemelor mecanice.
• Modul LeakQâ„¢: Dimensiunea È™i costul estimate ale scurgerii.
• Modul PDQâ„¢: Evaluează severitatea descărcării.
• Modul MecQâ„¢: Abordează proactiv potenÈ›ialele probleme ale componentelor mecanice rotative.
• FuncÈ›ii de raportare: FuncÈ›ionalități integrate de etichetare È™i adnotare vizuală È™i textuală pentru o raportare simplificată.
• ÃŽncărcare wireless: TransferaÈ›i cu uÈ™urință datele către Fluke Connect.

 

CALIBRATOR TEMPERATURA SI TERMOCUPLU FLUKE 714

• -200 to 1800ºC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output

 

CLESTE AMPERMETRIC DE CURENT 400A FLUKE 322

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

CALIBRATOR TERMOCUPLE FLUKE 714B

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration