Celula GTEM test, masura, incercari emisii electromagnetice si imunitate EMC ETS-Lindgren 5405

Cod: ETS-Lindgren 5405


 

Brosura produs PDF, 0.13 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f £ 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

250 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq £ 1.50:1
Characteristic Freq £ 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • One fiber optic penetration
  • 5400 GTEM! Series manual
  • Two AC receptacles
  • ETS-Lindgren absorber material
  • Completely assembled
  • Mobile base with locking casters
  • Three N-type connectors
  • Manual emissions correlation software (on request)
  • Primary door 18.11" W x 15.16" H clear opening (46 cm x 38.5 cm)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • One 20 amp, 2 line filter
 

Optiuni recomandate

  • Blower assembly
  • Blank panel with frame
  • Blank panel
  • Blank panel with connectors
  • Three Position Ortho-Axis Pneumatic Manipulator (light duty)
  • Panel with connectors and frame
  • Illumination assembly
  • Shielded Window for primary door
 

Alte produse ETS-LINDGREN

INCINTA ECRANATA TEST TRANSMISIE/ RECEPTIE PUNCT DE ACCES WLAN ETS-LINDGREN 5225

• Works with 802.11 Traffic Generator and Performance Analyzers
• Tests:
• -- Over-The-Air Performance of TX, RX
• -- Wireless LAN Access Point Throughput Performance
• Flat Coupling Response over 2.2GHz - 2.6GHz, 5.2GHz - 6.0GHz

 

FILTRE EMI DE PUTERE RETELE MONOFAZATE APLICATII TEMPEST/ EMC 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

FILTRE DE CONTROL APLICATII TEMPEST/ EMP/ EMI CURENTI 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

BOBINA HELMHOLTZ MONOAXIALA GENERARE CAMP MAGNETIC UNIFORM FRECVENTE JOASE ETS-LINDGREN 6400

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available

 

DIPOL SFERIC UNIVERSAL GENERARE RADIATII ELECTROMAGNETICE EMI ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

TESTER CAMP MAGNETIC 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA SPIRALA CONICA LOGARITMICA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

ANTENA DIPOL LOG-PERIODIC 80 MHZ..2 GHZ ETS-LINDGREN 3144

• Frequency Minimum 80 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW

 

FILTRE PROTECTIE TEMPEST/RFI/ EMI PETRU LINII TRANSMISII DATE ANALOGICE/ DIGITALE ETS-LINDGREN N2460

• Suitable for EMI and Tempest Protection
• Digital and analogue transmissions
• Tubular, flat-pack or modular design