Celula reverberanta teste emisii radiatii electromagnetice si imunitate radiata 1..40 GHz ETS-Lindgren Smart 1000

Cod: ETS-Lindgren Smart 1000


 

Brosura produs PDF, 0.1 Mb

Descriere

  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Accesorii standard

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Optiuni recomandate

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

Alte produse ETS-LINDGREN

ANTENA SPIRALA CONICA LOGARITMICA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

TESTER CURENT RF INDUS 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE LINII TRANSMISIE RETELE ENERGIE ELECTRICA ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

TESTER CAMP MAGNETIC 5..2000 HZ ETS-LINDGREN HI-3627

• 5 - 2000 Hz
• 0.2 mG - 20 G
• Three Concentric Orthogonal Field Sensors
• True RMS Detection
• Isotropic Response
• 100dB Dynamic Range

 

ANTENA HORN DESCHISA CUADRI-CREASTA 300 MHZ..6 GHZ ETS-LINDGREN 3164-06

• Frequency Minimum 300 MHz
• Frequency Maximum 6 GHz
• Connectors SMA Female (2)
• Cross Polarization Isolation >25 dB
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Linear or Circular Polarization (With Hybrid)

 

CONDENSATOARE RFI/ EMI DE ALIMENTARE CIRCUITE AC SI DC ETS-LINDGREN L265X

• All brass construction
• Excellent dv/dt characteristics
• These filters have NATO stock number codification
• High voltage proof withstand
• Design to meet Class Y specification

 

ANTENA DIPOL MAGNETIC BUCLA REZONANTA MASURATORI RIPLU TELECOMUNICATII MOBILE SI INTERNET CTIA 440..2665 MHZ ETS-LINDGREN 3127

• Range of Frequencies to Cover Wireless Device Bands: 440...2665 MHz
• Designed for CTIA Ripple Test
• Meet CTIA +/- 0.1 dB Symmetry Requirement

 

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA HORN GHID DE UNDE PENTRU MASURATORI EMC 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz
• Peak Power 2500 W