  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Accesorii standard

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Optiuni recomandate

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

Alte produse ETS-LINDGREN

ANTENA BICONICA TRANSMISIE-RECEPIE 20..200 MHZ ETS-LINDGREN 3104C

• Frequency Minimum 20 MHz
• Frequency Maximum 200 MHz
• Connectors Type N (f)
• FS-600 High Performance Hybrid Ferrite Tile Polyurethane Dielectric 200 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Pattern Type omnidirectional
• Peak Power 100 W
• Polarization linear

 

ANTENA HORN DESCHISA CUADRI-CREASTA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

MATERIALE ABSORBTIE RADIATII EMC SI MICROUNDE ETS-LINDGREN

• EMC Anechoic Absorber
• Ferrite Tile Absorber
• FerroSorb FS EMC Absorber
• FerroSorb PS EMC Absorber
• Ultra Broadband Microwave Absorber

 

FILTRE PROTECTIE EVENIMENTE TRANZITORII RETEA TRIFAZATA APLICATII RFI/EMP PUTERE & CURENT INALT 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

STABILIZATOARE IMPEDANTA LINIE DE RETEA ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


ANTENA HORN CONICA LINIAR POLARIZATA SI CASTIG RIDICAT 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

ANTENA HORN LINIAR POLARIZATA OCTAVA 1..8 GHZ ETS-LINDGREN 3161

• Frequency Minimum 1 GHz
• Frequency Maximum 8 GHz
• Pattern Type directional
• Polarization linear
• Constant Antenna Factor Over Frequency
• Complete with Feed, Waveguide, Mount

 

FILTRE PUTERE APLICATII TEMPEST/RFI/ EMI DE MARE PERFORMANTA CURENTI 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers