Celula reverberanta teste emisii radiatii electromagnetice si imunitate radiata 1..40 GHz ETS-Lindgren Smart 1000

Cod: ETS-Lindgren Smart 1000


 

Brosura produs PDF, 0.1 Mb

Descriere

  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Accesorii standard

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Optiuni recomandate

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

Alte produse ETS-LINDGREN

ANTENA DE BANDA LARGA OMNIDIRECTIONALA 1..18 GHZ ETS-LINDGREN 3183

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1GHz, 25 watts @ 18 GHz
• Chamber Characterization
• Broadband Spectrum Monitoring

 

ANTENA MONOPOL PASIV DE TRANSMISIE CAMP ELECTRIC 1 KHZ..30 MHZ ETS-LINDGREN 3303

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Peak Power 1 W
• Polarization linear
• Switchable Two-band Transformer
• Two Year Warranty

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

INCINTA ECRANATA TESTARE DISPOZITIVE WIRELESS ETS-LINDGREN 5247

• Roll-About Casters
• Portable RF Shielded Enclosure for OTA measurements
• >80 dB Typical RF Isolation
• RF Absorber Lined
• Dual Polarized Horn Antenna
• 700 MHz - 10 GHz Frequency Range
• Linear & Circular Polarization

 

SISTEM MONITORIZARE CAMP ELECTROMAGNETIC DE BANDA LARGA 10 KHZ..40 GHZ ETS-LINDGREN HI-6100 E-FIELD MONITOR

• HI-6100 Field Monitor with 4 Probe Input Channels
• Large Color LCD Display
• IEEE-488, RS-232, USB Interfaces
• USB & RS232 Interface Modules available for Record & View measurements
• Electric Field Probes for 10 kHz..40 GHz frequencies

 

GENERATOR CAMP ELECTRIC VERTICAL UNIFORM 10 KHZ..30 MHZ ETS-LINDGREN 5503

• Generates large area uniform vertical electric field
• 10 kHz - 30 MHz frequency range
• Accommodates various EUT sizes with adjustable height feature
• Temperature maintained with external forced-air cooling, and monitored by temperature sensor
• Easy to assemble/disassemble and remove from the chamber

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN GHID DE UNDE PENTRU MASURATORI EMC 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz
• Peak Power 2500 W

 

BOBINA HELMHOLTZ MONOAXIALA GENERARE CAMP MAGNETIC UNIFORM FRECVENTE JOASE ETS-LINDGREN 6400

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available

 

FILTRE PUTERE TEMPEST/ EMI/ EMC DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes