Celula GTEM test, masura, incercari emisii radiatii electromagnetice si imunitate EMC ETS-Lindgren 5411

Cod: ETS-Lindgren 5411


 

Brosura produs PDF, 0.93 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

1 kW

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq 1.50:1
Characteristic Freq 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Two AC receptacles
  • Forced air ventilation
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • Removable bolt-on feed section
  • Additional maintenance kit
  • Three N-type connectors
  • Customer will need to provide manpower and specific tools
  • Shipped disassembled
  • Air compressor for manipulator brake system
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • 7/16" DIN to type "N" adaptor
  • One fiber optic penetration
  • ETS-Lindgren absorber material
  • One 20 amp, 2 line filter
  • Mobile base with locking casters
  • Blank feed-thru panel without frame
  • Additional copy of emissions correlation software
  • Primary door 27" W x 36.42" H clear opening (68.6 cm x 92.5 cm)
  • Individually characterized with results of TDR and VSWR tests
 

Optiuni recomandate

  • Window with frame (added to primary door)
  • Blank feed-thru panel, installed
  • GTEM! Theory and training - 2 days
  • Power distribution box
  • Additional 30 amp filter, three phase
  • Feed-thru panel with 3 "N" connectors and 1 fiber optic penetration, uninstalled
  • Secondary door with window
  • Secondary door without window
  • Blank feed-thru panel, uninstalled, no frame assembly
  • Additional 20 amp filter, single phase
  • Automated manipulator
  • Dual telephone filter (same as RP59001)
  • AC power filter, .5 amps, 120 V
  • High voltage feed section
  • Additional primary door without window
  • Manual manipulator
  • DC power filter with banana jacks
  • Illumination kit
  • Pneumatic brake kit upgrade for manipulators with electric brake systems
  • Additional 30 amp filter, single phase
 

Alte produse ETS-LINDGREN

ANTENA HORN PIRAMIDAL CU GENERARE CAMP ELECTRIC TESTARE EMC AUTO GMW 3097 SI ES-XW7T-1A278-AC 1.2..1.4 GHZ ETS-LINDGREN 3162-01

• Frequency Minimum 1.2 GHz
• Frequency Maximum 1.4 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 550 W
• Pattern Type directional
• GMW 3097
• ES-XW7T-1A278-AC

 

ANTENA LOG-PERIODICA POLARITATE LINIARA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

ANTENA SPIRALA CONICA LOGARITMICA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA DIPOL DE PRECIZIE CALIBRARE & MASURA RIPLU COMUNICATII MOBILE SI INTERNET CTIA 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

ANTENA HORN PIRAMIDAL MULTI-OCTAVA LINIAR POLARIZATA 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

FILTRE PUTERE APLICATII TEMPEST/RFI/ EMI DE MARE PERFORMANTA CURENTI 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

TESTER CAMP MAGNETIC 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

ANTENA BUCLA CU GENERARE CAMP MAGNETIC FRECVENTA JOASE 20 HZ..50 KHZ ETS-LINDGREN 7603

• Frequency Minimum 20 Hz
• Frequency Maximum 50 kHz
• Connectors Banana Jack (2)
• Impedance (Nominal) 50 ?
• Maximum Input Power 5 A
• Pattern Type omnidirectional
• Polarization linear

 

CELULA REVERBERANTA TESTE EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE RADIATA 1..40 GHZ ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements