Megger TDR500/3 Time domain reflectometer & cable fault locator 1002-227

Code: Megger TDR500/3 1002-227


 

Datasheet PDF, 0.28 Mb

Description

• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

 

The TDR500/3 is a hand held, compact Time Domain Reflectometer for locating faults on metallic cables. It has a minimum resolution of 0.1 m and a 5 km maximum range depending on velocity factor selected and cable type.

Four output impedances are available (25, 50, 75, and 100 O) and a velocity factor between 0.2 and 0.99 will meet any cable test requirements.

 

Standard accessories

Time Domain Reflectometer 1002-227

Included accessories

Hard carry case 5410-420

Miniature clip test lead set 6231-652

User guide CD 2002-178

 

Optional accessories

Fused test lead set 1002-015

 

More products MEGGER

MEGGER TTRU3 THREE-PHASE TRANSFORMER TURN RATIO TESTER

• Guaranteed accuracy ±0.05% from -20°C to +50°C
• 3Ø test voltage - up to 250V
• 3Ø step up ratio (patented)
• Phase shifting & zig-zag transformers tested
• easily and accurately
• Smallest/lightest 3Ø test set on the market
• Fast 3Ø tests - less than 10 seconds

 

MEGGER MPRT2145 SINGLE PHASE RELAY TESTER

• Open communication architecture for third party software application
• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (60 amps/400 VA rms)
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 


MEGGER MIT400/2 MIT410/2 MIT420/2 MIT430/2 CAT IV INSULATION TESTER WITH 1000V

• nsulation testing up to 1000 V and 200 GΩ range
• Stabilised insulation test voltage (New)
• Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New)
• 600 V T RMS AC and DC voltage measurement

 

ELECTRICIAN'S MULTIMETER MEGGER - AVO410

• 6000 count backlit digital display
• True RMS reading on a.c. mode
• 1000 V d.c. / 750 V a.c. ranges
• 10 A a.c. / d.c. ranges

 

MEGGER CARLOC CABLE LOCATION TRACING TRACE ROUTE

• Display with high contrast for good readability by day and night
• Current direction indication for clear cable identification
• Transmitter with two output signals to distinguish between cables lying side by side
• IP 65 for wet, dusty, and dirty working environments
• 100 freely adjustable transmitter frequencies (from 50 Hz to 200 kHz)

 

MICRO-OHMMETER MEGGER MOM690A

• Easy-to-use
• Automatic range settings
• MOM Win PC software

 

MEGGER SVERKER 650 PROGRAMMA SINGLE PHASE RELAY TESTER

• Designed for rugged field use
• 0 to 100 Amp output current
• Suitable for testing many different types of relays such as power, voltage and current
• Easy to operate

 

MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive

 

MEGGER DELTA4310 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA 4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design