Vacuum Interrupter Tester Megger - VIDAR

Code: Megger - VIDAR


 

Datasheet PDF, 0.2 Mb

Description

When a vacuum circuit breaker is commissioned or undergoes routine tests, it is very important to be able to ascertain whether or not the Vacuum Interrupter (VI) is intact before putting it back into operation.

 

VIDAR enables you to check the integrity of the vacuum interrupter quickly and conveniently by means of the known relationship between the flashover voltage and the vacuum interrupter. A suitable test voltage (DC) is applied to the breaker, and the result is known immediately.

 

Features:

  • Tests the integrity of vacuum interrupters quickly, safely and easily
  • User defined voltage selection
  • Extensive voltage range
  • Easy to operate. Follows ANSI/IEEE standardized DC test methods.
  • Lightweight and portable
 

More products MEGGER

MEGGER DET14C 1000-761 DET24C 1000-762 EARTH RESISTANCE CLAMP METER

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

DUAL POWER MICRO-OHMMETER MEGGER DLRO10HDX DUCTER

• Interchangeable test lead terminations
• High or low output power selection for condition diagnosis
• Operates from battery or AC mains supply
• Protected to 600 V without blowing a fuse, test lead live voltage warning light

 

MEGGER FREJA 400 PROGRAMMA RELAY TEST SYSTEM FREJA400

• FREJA 403 3x60 A at 300 VA per phase.
• FREJA 406 Up to 6 channels: 3 x 60 A and 3 x 15 A
• FREJA 409 Up to 9 channels: 6 x 60 A and 3 x 15 A
• Voltage outputs : Up to four channels 300 V at 150 VA
• Fully automated testing using FREJA Win software
• PC operated or stand alone using the intuitive graphic touch screen
• High current, high power output (60 A / 300 VArms) per phase
• FREJA 409 provides 3 x 120 A in threephase configuration mode
• FREJA 406 provides 6 currents, and FREJA 409 provides 9 currents for transformer differential testing
• IEC 61850 test capabilities

 

MEGGER MIT480/2 MIT481/2 MIT485/2 INSULATION TESTER FOR COMMUNICATIONS 500V

• Insulation testing up to 500 V and 100 GΩ range in a hand held instrument
• 3-wire connection for A, B, and E (Tip, Ring and Ground/Earth) connection
• Gated access to 500 V to prevent accidental damage
• CAT IV 600 V and IP 54

 

MEGGER TDR2000/3 1003-036 TDR2000/3P 1003-037 DUAL CHANNEL CABLE TDR

• best resolution of 0.1m the TDR2000/2 has a 20km maximum range
• Comprehensive Dual Channel capability with dual aspect display.
• AUTO set up mode for instant use.
• Ultra fast pulse for near end fault identification.
• Xpert guidance to potential fault.
• IP54 rating offers real life working.
• Designed for use on all metallic paired cables.

 

DIGITAL MULTIMETER MEGGER - DCM340

• DC and AC current and voltage
• 600 A and 600 V
• Resistance and continuity
• 31/2 digit, 4000 count display with backlight
• High resolution digital bargraph

 

MEGGER IDAX-300 IDAX-350 INSULATION DIAGNOSTIC ANALYZER, TAN DELTA, POWER FACTOR

• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity
• Individual temperature correction (ITC) of tan delta/power factor and oil conductivity
• 40% faster measurements with the new IDAX 5.0 SW
• Reliable measurements in high-interference environments
• Multi-function test set for transformer measurements

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

MEGGER MPAC208 ACOUSTIC CAMERA FOR GAS LEAKS, MECHANICAL FAULTS AND PARTIAL DISCHARGES

• Pinpoint issues fast
• Quantify leak and energy loss
• Reliable PD insight
• Works in noisy environments
• Optional thermal overlay
• Available in comprehensive kit

 

MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive