Universal Circuit Breaker Test Sets Megger PS-9130 and PS-9160

Code: Megger PS-9130 and PS-9160


 

Datasheet PDF, 0.1 Mb

Description

Model PS-9130 and Model PS-9160 Series Universal Circuit Breaker Test Sets are specifically designed to test low-voltage power circuit breakers and molded-case circuit breakers that are equipped with thermal magnetic or solid-state trip devices by simulating an overload or fault condition.

 

Model PS-9130 and Model PS-9160 are controlled by the Model PLC-2000 Prime Logic Controls. This microprocessor monitors the output, stores the test data and performs the automatic test functions. After the test information is stored, Model PLC-2000 can print the test data using a built-in RS-232 printer port.

 

Features:

  • Proven power train
  • Rugged instrumentation and controls
  • Direct connection of draw-out type breakers
  • Integral clock/calendar
  • Easy-to-read display
 

More products MEGGER

ELECTRICIAN'S MULTIMETER MEGGER - AVO210

• 2000 count digital display
• 1000 V DC / 750 V AC ranges
• 10 A AC / DC ranges
• Resistance, frequency and capacitance ranges

 

MEGGER FREJA 300 PROGRAMMA RELAY TESTER CF-19091

• can generate 4x150 V (82 VA) and 3x15 A (87 VA) or 1x45 A (250 VA).
• Manual and automatic control
• Easy to use
• Excellent software provides great visuals and simple setup
• Lightweight and portable
• Highly accurate
• User can calibrate unit

 


MEGGER DLRO10HD 10A MICROHMMETER LOW RESISTANCE MEASUREMENTS

• High or low output power selection for condition diagnosis
• Rechargeable battery or line power supply, continuous operation, even with dead battery
• 10 A for 60 seconds, less time waiting to cool, great for charging inductance
• High input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse
• Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)
• Rotary switch selects one of five test modes, including auto start on connection, giving ease of use

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MICRO-OHMMETER MEGGER MOM600A

• Compact and tough
• Straight forward to use
• 600 A output current

 

MEGGER TDR2000/2 TDR CABLE REFLECTOMETER FAULT LOCATOR TDR2000/2RM TDR2000/2R

• 20 km range at VF = 0.90
• Monochrome or colour options
• Primary cell or rechargeable options
• Large back lit LCD Display
• Dual cursor measurement
• Intermittent fault location
• Output pulse amplitude and width control
• Trace Master PC software included
• IP54 Rating
• 2 year Warranty

 

MEGGER DET3TC DET3TD EARTH RESISTANCE TESTER

• 2 and 3 point testing
• ART (Attached Rod Technique) testing capability with DET3TC
• Choice of digital or analog display
• Warning indicators prevent test failure
• IP54 rated
• Complete with leads, stakes and rugged carry case
• Simple one button operation
• Calibration test certificate included

 

MEGGER MIT2500 2.5KV INSULATION TESTER

• Insulation testing up to 2.5 kV and 200 GΩ range in a handheld instrument
• Guard terminal for high resistance accuracy
• Adjustable insulation test voltage from 50 V to 2500 V
• Stabilised insulation test voltage

 

EARTH LEAKAGE CLAMPMETER MEGGER - DCM300E

• 0.01 mA resolution
• EMC and IEC61010-2-032 compliance
• 30 mA, 300 mA, 30 A and 300 A range