Multi-amp Circuit Breaker Tester Retrofit Megger DDA16, DDA30 and DDA60

Code: Megger DDA16, DDA30 and DDA60


 

Datasheet PDF, 0.04 Mb

Description

The DDA-16, DDA-30, DDA-60 use the latest in DSP technology to control the circuit breaker test sets and also measure the reactions of the breaker under test. The retrofit capabilities allow a user of Multi-Amp circuit breaker tests sets the capability of upgrading existing systems without the expense of purchasing a new system. The DSP technology provides complete digital control of the SCRs and digitally samples the output current for high-accuracy measurements.

 

Features:

  • Drop-in retrofit capability to the Multi-Amp Model CB-9116, Model DB-8130 and Model CB-8160 circuit breaker test sets
  • Digital Signal Processing (DSP) technology
  • Variable pulse time and firing-angle output-current control
  • Complies with NEMA AB-4 Test Guidelines
 

More products MEGGER

MEGGER SMRT410 RELAY TEST SYSTEM

• Small, rugged, lightweight and powerful
• Operates with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output (60 Amps/300 VA rms) per phase
• Flexible output design provides up to 4-phase voltage and up to 10-phase current
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER TTR25 TRANSFORMER TURNS RATIO METER, EXCITATION CURRENT, POLARITY

• Fully automatic; fast; easy-to-use; robust; lightweight
• Battery powered
• Tests turns ratio, excitation current, and polarity
• Simple, one-button operation
• Quick-start guide on front panel
• Operator-selectable languages

 

MEGGER MTO210 TRANSFORMER WINDING OHMMETER

• Direct 2-channel digital reading (1 µO to 2000 O)
• DC test current up to 10 A maximum
• 0.25% measurement accuracy
• Integrated demagnetization feature
• Tests operation of on-load tap-changers
• Very fast auto safety discharge circuit

 

MEGGER BGFT 246100B BATTERY GROUND FAULT TRACER

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

MEGGER MPQ2000 POWER ENERGY QUALITY ANALYZER CLASS-A

• Powered off of phase A voltage AC/DC
• Weatherproof to IP54 standard for use in any environment
• 1000 VAC and 1500 VDC range
• Auto CT identifies the current that the instrument is connected to and the range that it is in
• Real time scope and DVM
• IEC61000-4-30 Class A compliance

 

MEGGER TDR500/3 TIME DOMAIN REFLECTOMETER & CABLE FAULT LOCATOR 1002-227

• minimum resolution of 0.1 m and a 5 km maximum range
• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

MICRO-OHMMETER MEGGER MOM600A

• Compact and tough
• Straight forward to use
• 600 A output current

 

FREQUENCY RESPONSE ANALYZER MEGGER FRAX200 FRAX150 FOR POWER TRANSFORMER

• High dynamic range and accuracy
• Easy-to-use support software with advanced analysis tools
• Smallest SFRA instrument in the industry
• Hardware designed to ensure repeatable connections
• Fulfils international standards for SFRA

 

MEGGER MIT1015 10KV INSULATION RESISTANCE MEGOHMMETER

• RE>Act mode enhanced accuracy and safety
• PI predictor function (PIp)
• Measures up to 20 TΩ
• Up to 3 mA noise rejection

 

MEGGER FRAX FRAX-99 FRAX-101 FRAX-150 FREQUENCY RESPONSE ANALYZER

• Frequency range 0.1 Hz - 25 MHz, user selectable
• Highest dynamic range and accuracy in the industry
• Smallest and most rugged FRA?instrument in the industry
• Fulfills all international standards for SFRA measurements
• Advanced analysis and decision support built into the software
• Imports data from other FRA test sets