Double-Ridged Microwave Guide Horn Antenna 750 MHz..18 GHz ETS-Lindgren 3115

Code: ETS-Lindgren 3115


 

Datasheet PDF, 0.48 Mb

Description

  • Frequency Minimum     200 MHz
  • Frequency Maximum    2.5 GHz
  • Connectors       Type N (f)
  • Impedance (Nominal)   1600 W
  • Maximum Continuous Power    800 W
  • Pattern Type     directional
  • Peak Power     1600 W
  • Polarization       linear
  • VSWR <1.6:1
  • Two Year Warranty
  • Uniform Gain
  • Low VSWR
  • Individually Calibrated
  • Power Handling Capability - 1.6 kW
 

More products ETS-LINDGREN

ELF MAGNETIC FIELD SURVEY METER 5..2000 HZ ETS-LINDGREN HI-3627

• 5 - 2000 Hz
• 0.2 mG - 20 G
• Three Concentric Orthogonal Field Sensors
• True RMS Detection
• Isotropic Response
• 100dB Dynamic Range

 

RF ATTENUATION AND ELECTROMAGNETIC SHIELDING METER 8..64 MHZ ETS-LINDGREN MF-130D

• Measurement frequencies: 8 MHz, 16 MHz, 32 MHz and 64 MHz
• Makes Shielding Attenuation
• MIL-STD-285 Measurements
• NSA 65-6 Measurements
• IEEE STD-299 Measurements
• EN 50147-1 Measurements
• Stores/Downloads up to 63
• Includes Windows® Compatible Easy-To-Use, Portable Software

 

RF ELECTROMAGNETIC SURVEY METER ETS-LINDGREN HI-2200

• Handstrap & Safety Lanyard Mount
• Optional Fiber Optic Link
• Interchangeable Probe Heads
• Small/Lightweight for minimal field perturbance
• Broadband Frequency Range
• Economical Solution to Broadcast/Telecom Safety Monitoring Needs & Environmental Monitoring

 

ELECTROMAGNETIC FIELD EMISSION MEASURING TESTER OF VIDEO DISPLAYS ETS-LINDGREN HI-3603

• VDT / VLF Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

CONICAL LOG SPIRAL ANTENNA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive