GTEM Test Cell for EMC Radiated Emissions & Immunity ETS-Lindgren 5402

Code: ETS-Lindgren 5402


 

Datasheet PDF, 0.12 Mb

Description

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Standard accessories

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Recommended options

  • Blank connector panel
 

More products ETS-LINDGREN

ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity

 

PRECISION DIPOLE ANTENNA WITH OMNI-DIRECTIONAL EMISSIONS FOR IMMUNITY TESTING 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements

 

PROTECTION TEMPEST/ RFI/ EMI FILTERS FOR TELECOM ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines

 

CONICAL LOG SPIRAL ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3103

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Two Year Warranty
• Extremely low VSWR

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz
• Peak Power 2500 W

 

FIELD GENERATING PYRAMIDAL HORN ANTENNA FOR EMC AUTOMOTIVE TESTING ES-XW7T-1A278-AC 2.7..3.1 GHZ ETS-LINDGREN 3162-02

• Frequency Minimum 2.7 GHz
• Frequency Maximum 3.1 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Polarization linear
• Meets Specs for ES-XW7T-1A278-AC

 

LINEAR POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

WLAN ACCES POINT TEST ENCLOSURE ETS-LINDGREN 5225

• Works with 802.11 Traffic Generator and Performance Analyzers
• Tests:
• -- Over-The-Air Performance of TX, RX
• -- Wireless LAN Access Point Throughput Performance
• Flat Coupling Response over 2.2GHz - 2.6GHz, 5.2GHz - 6.0GHz

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B

• Frequency Minimum 200 MHz
• Frequency Maximum 2.5 GHz
• Connectors Type N (f)
• Impedance (Nominal) 1600 W
• Maximum Continuous Power 800 W
• Pattern Type directional