GTEM Test Cell for EMC Radiated Emissions & Immunity ETS-Lindgren 5402

Code: ETS-Lindgren 5402


 

Datasheet PDF, 0.12 Mb

Description

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Standard accessories

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Recommended options

  • Blank connector panel
 

More products ETS-LINDGREN

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVENS ETS-LINDGREN HI-1600

• Calibrated at 915 MHz and 2450 MHz
• Three Ranges

 

UNIVERSAL SPHERICAL DIPOLE EMI RADIATION SOURCE ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

EMI POWER FILTERS IN TEMPEST/ EMC SYSTEM SINGLE LINE NETWORK 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

ELECTROMAGNETIC FIELD EMISSION METER OF ELECTRIC TRANSMISSION ELECTRIC POWER LINES ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

ACTIVE MONOPOLE RECEPTION ANTENNA 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

CONICAL LOG SPIRAL ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3103

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Two Year Warranty
• Extremely low VSWR

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

UNIFORM VERTICAL ELECTRIC FIELD GENERATOR 10 KHZ..30 MHZ ETS-LINDGREN 5503

• Generates large area uniform vertical electric field
• 10 kHz - 30 MHz frequency range
• Accommodates various EUT sizes with adjustable height feature
• Temperature maintained with external forced-air cooling, and monitored by temperature sensor
• Easy to assemble/disassemble and remove from the chamber