EMI Power Filters in Tempest/ EMC system single line network 32..120A ETS-Lindgren N192X

Code: ETS-Lindgren N192X


 

Datasheet PDF, 1.02 Mb

Description

  • Current Range 32 to 250 Amperes
  • Very High RF Attenuation
  • Fully Tested for Attenuation Performance
  • Durable Construction
  • CE Marked

 

APPLICATIONS

  • In high performance screened rooms, providing sufficient attenuation of both the incoming and outgoing mains supply lines to match the shield performance.
  • In TEMPEST applications where the very highest degree of protection is required to obtain maximum security.
  • In EMP protection systems.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Freq. (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz Sys. Per Line (Max)

DC Resistance Per Line (milliohms)

N1923

32

250

DC/50/60

Single

0.6

24

N1923

20

120

400

Single

0.6

24

N1924

63

250

DC/50/60

Single

0.7

9

N1924

40

120

400

Single

0.7

9

N1925

100

250

DC/50/60

Single

0.9

5

N1925

60

120

400

Single

0.9

5

N1926

200

250

DC/50/60

Single

0.9

2.5

N1926

120

120

400

Single

0.9

2.5

N1926/250

250

250

DC/50/60

Single

0.9

2.5

N1926/250

120

120

400

Single

0.9

2.5

 

More products ETS-LINDGREN

MAGNETIC FIELD MEASUREMENT PROBE 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

RFI/ EMI CONTROL FILTERS FOR ALARM, DETECTION AND MONITORING SYSTEMS ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BULK INJECTION CURRENT PROBES 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3112

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 800 W
• Maximum Power 2 kW

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

BROADBAND OMNIDIRECTIONAL ANTENNA FOR SPECTRUM MONITORING 500 MHZ..18 GHZ ETS-LINDGREN 3181

• Frequency Minimum 500 MHz
• Frequency Maximum 18 GHz
• Connectors SMA (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts @ 500 MHz, 25 watts @ 18 GHz

 

ELECTRIC FIELD MEASUREMENT PROBES 500 KHZ..5 GHZ ETS-LINDGREN HI-4433

• Frequency Range: 500kHz - 5GHz
• Automatic Continuous Zeroing
• Fiber Optic Technology
• Dynamic Range down to 300 mA/m
• Data from each axis can be viewed individually