Privacy policies
• Continuity of protective conductors with 200mA • Polarity • Open circuit voltage Voc of PV modules and strings 1500V • Short circuit current Isc on PV modules and strings 40A • PV string/field insulation with test voltage 250, 500, 1000, 1500VDC
• Continuity of protective circuit with 200mA • Polarity • Open circuit voltage Voc of PV modules and strings 1000V • Short circuit current Isc on PV modules and strings 30A • PV string/field insulation with test voltage 250, 500, 1000VDC • Measurement of polarization index P.I. • Dielectric absorption ratio D.A.R • GFL function to locate the fault position in the string • Measurement category CAT III 1000V • OPT function for insulation testing on PV strings in the presence of MLPE
• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891 • SOLAR03 remote unit with Bluetooth connection • Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2 • Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)
• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations. • Measurement of efficiency of a single-phase photovoltaic system • Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A • Measurement of open-circuit voltage of a module or of a string (VOC) 1500V • Measurement of short-circuit current of a module or of a string (ISC) 15A
• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems. • Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A • Measurement of open-circuit voltage and short-circuit current Voc/Isc • Database of 30.000 selectable photovoltaic modules
• Insulation measurement up to 1,500V DC even on live systems • Localization of the faulty module through the new GFL function • Continuity of the protective conductor with 200mA
• Safety test of PV installation • Continuity test on protective conductors with 200mA • Insulation test with test voltage of 250, 500, 1000VDC • DC voltage • DC current • DC Power • Solar irradiation [W/m2] with reference cell
Obsolete products ( * out of use )
• Measurement of output voltage from module/string up to 1000V DC• Measurement of output current from module/string up to 10A DC• Measurement of solar irradiation [W/m2] with reference cell• Measurement of environmental/module temperature, automatic or by means probe• Measurement of output DC and nominal power from module/string• Numerical and graphical display of I-V characteristic• Optical/USB port for PC connection
• Testing on PV installation • I-V curve measurement • DC/AC TRMS Voltage • DC/AC TRMS Current • DC power • AC active power on single-phase systems • Solar irradiation [W/m2] with reference cell • Optical/USB port for PC connection
• Continuity of protective conductors with 200mA • Insulation with test voltages of 50, 100, 250, 500, 1000VDC • Tripping time of RCDs type A, AC, general and selective up to 500mA • Tripping current of RCDs type A, AC, general and selective up to 500mA • Impedance of Loop/Line P-N, P-P, P-PE, also with high resolution (0,1mOhm) • Ipsc calculation• Optical/USB interface for PC connection
• DC/AC TRMS (single-phase and three-phase) voltage and current measurement• DC/AC (single-phase and three-phase) power measurement• AC (single-phase and three-phase) energy measurement• Measurement of power factor (cosphi) single-phase and three-phase• Measurement of solar irradiation [W/m2]• Recording of voltage and current harmonics up to the 49th• Recording of voltage anomalies (dips, peaks)• Flicker analysis in compliance with standard EN50160