Safety Tester for Photovoltaic Systems HT PVCHECK

Code: HT PVCHECK


 

Datasheet PDF, 0.12 Mb

Description

Multifunction instrument to check safety, parameters and performance of a PV plant

 

 

The multifunction instrument PVCHECK allows prompt and safe electrical checks required for a PV system (section DC) as well as controls on working of  modules / strings in accordance with IEC/EN62446 guidelines. PVCHECK verifies the  continuity of the protective conductors (and the associated connections) and executes insulation resistance measurement of the active conductors on a module, a string or a photovoltaic field in accordance with the requirements of IEC/EN62446, without the need of short-circuiting the positive and negative terminals. PVCHECK allows verification of  a PV string's working in accordance with the requirements of IEC/EN62446 by measuring the open circuit voltage and short-circuit current under operating conditions and reporting the results to STC (by means of radiation measurement). It provides an immediate outcome for both absolute measurements and for measurements compared  with the previously tested PV strings.
PVCHECK also allows carrying out performance analysis of PV array (DC) under operating conditions (connected to the inverter) providing an indication of the power generated and the efficiency of the field as specified by IEC/EN62446.

 

  • Safety test of PV installation
  • Continuity test on protective conductors with 200mA
  • Insulation test with test voltage of 250, 500, 1000VDC
  • DC voltage
  • DC current
  • DC Power
  • Solar irradiation [W/m2] with reference cell
  • Environmental  and module temperature by means of PT1000 probe
  • SOLAR-02: remote unit for irradiance and temperature measurements (RF connection).
  • Recording of PV plant parameters (DC side) with programmable IP (5s � 60min)
  • Use of PDC compensation ratios according to environmental and module temperature
  • Use of relationship to maximize the DC efficiency
  • Outcome OK/NO
  • Check of PV string's working
  • Measurement of open circuit voltage up to 1000V DC
  • Measurement of short circuit current up to 10A DC
  • Measurement of temperature, automatic or by means of  PT1000 probe
  • Measurement of solar radiation [W/m2] with reference cell
  • Mechanical inclinometer for the detection of solar radiation incidence angle
  • Comparison with standard conditions (STC 1000 W/m2, 25�C)
  • Outcome of testing: OK / NO
  • Database to manage up to 30 types of photovoltaic modules
  • Internal memory for data saving
  • Optical/USB port for PC connection
  • Help on line on display

 

 

Standards

EMC 2004/108/CE Directive
CE MARK
IEC/EN 61010-032
IEC/EN 61010-1
IEC/EN61557-1
IEC/EN61557-2
IEC/EN61557-4
IEC/EN62446
LVD 2006/95/CE Directive

 

Standard accessories

STANDARD

  • KITGSC4 : Set 4 cables + 4 alligator clips
  • KITPCMC3 : Set of 2 multi-contact one wire for MC3 connectors
  • KITPCMC4 : Set 2 multi-contact one wire for MC4 connectors
  • HT4004 : Standard clamp for  DC current up to 100A
  • TOPVIEW2006 : Windows software + optical/USB cable C2006
  • BORSA2051 : Soft carrying bag
  • User manual on CD-ROM
  • Quick reference guide
  • ISO9000 calibration certificate
 

Recommended options

  • SOLAR-02 : Remote unit for irradiance/temperature
  • HT304N : Reference cell for radiation measurements
  • PT300N : PT1000 probe for cell temperature measurement
  • M304 : Mechanical inclinometer
  • SP-0400 : Set of straps for use of meter on neck
 

More products HT ITALIA

DIGITAL PORTABLE MULTIMETERS HT ITALIA

• DC Voltage
• AC TRMS Voltage
• DC Current
• AC TRMS Current

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

PROFESSIONAL MULTIMETER CABLE VERIFIER FOR LAN VDE CHECKING HT ITALIA M75

• DC Voltage
• AC TRMS Voltage
• Continuity test of protective conductors with 200mA
• Insulation Resistance measurement with 500VDC
• Global Earth Resistance without RCD tripping
• Test executed on twisted pairs cables UTP and STP with RJ45 connector
• Quickly selection of cables pairs

 

FULLTEST3 MULTIFUNCTION TESTER FOR SAFETY OF MACHINERY IEC/EN60204-1 AND LOW VOLTAGE SWITCHGEARS AND CONTROLGEARS IEC/EN61439-1-2

• IEC/EN60204-1 and IEC/EN61439-1-2 Measuments
• Continuity of protective circuit with 200mA
• Continuity of protective circuit with I>10A, V<12V
• Continuity of protective circuit with I>25A, V<12V
• Insulation with test voltages 100, 250, 500, 1000VDC
• Dielectric strength with voltage programmable from 250V to 5100VAC

 

DIGITAL PROGRAMMABLE PROFESSIONAL MEGOHMMETER 10TOHM 5KV HT ITALIA HT7051

• Insulation resistance measurement with test voltage up to 5kVDC
• Measurement range up to 10Tohm
• Polarization Index (P.I.) measurement
• Dielectric Absorption Ratio (D.A.R) measurement
• RS-232 interface for PC connection
• Rechargeable internal battery

 

HT GSC60 MULTIFUNCTION ELECTRICAL INSTALLATION TESTER WITH POWER QUALITY ANALYSIS

• Insulation with voltage 50, 100, 250, 500, 1000VDC
• Three-phase Power quality and Energy consumption analysis
• 632 parameters can be recorded for over two months
• Voltage/current vector diagram
• Voltage/current waveforms
• Tables or histograms of Harmonics and THD%
• Integrated WiFi connection and compatibility with HTANALYSIS App

 

POWER ANALYZER CURRENT CLAMP METER HT ITALIA HT9022

• DC, AC + DC TRMS current up to 1000A
• DC, AC + DC TRMS voltage up to 1000V
• Resistance and continuity test
• Active, Reactive, Apparent power on Single/Three phase systems
• Active, Reactive energy on Single/Three phase systems
• Power Factor on Single/Three phase systems
• Harmonic voltage/current up to 25th with THD% calculation
• PC connection via Bluetooth

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl