Electrical Safety Installation Tester on Photo Voltaic System HT Italia Solar200
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia Solar200


 

Datasheet PDF, 0.38 Mb
 

Description

  • Continuity of protective conductors with 200mA
  • Insulation with test voltages of 50, 100, 250, 500, 1000VDC
  • Tripping time of RCDs type A, AC, general and selective up to 500mA
  • Tripping current of RCDs type A, AC, general and selective up to 500mA
  • Impedance of Loop/Line P-N, P-P, P-PE, also with high resolution (0,1mOhm)
  • Ipsc calculation.
  • Total earth resistance with no RCD tripping
  • Contact voltage
  • Phase sequence
  • Activation of measurements with optional remote probe PR400
  • Saving of results
  • Recalling results on the display
  • Optical/USB interface for PC connection
  • Help on line on the display
 

Standard accessories

  • C2033X: 3-banana to Shuko plug cable
  • UNIVERSALKIT: Kit including 3 cables + 3 alligator clips + 1 test lead
  • BORSA75: Carrying bag
  • User manual
  • Calibration certificate ISO9000
 

Recommended options

  • TOPVIEW2006: Software on CD-ROM and optical-to-USB connection cable C2006
  • PR400: Test lead with remote START button
  • IMP57: High resolution impedance measurements adapter
  • SP-0400: Free hands kit
 

More products HT ITALIA

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

INFRARED NON CONTACT THERMOMETER HT ITALIA

• Infrared temperature measurement from -50°C to 1000 °C
• Emissivity regulation
• Distance / Spot ratio of 50:1
• Laser pointer activation

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

EARTH GROUNDING RESISTANCE MULTIMETER HT ITALIA M71

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• Measurement range up to 50kOhm
• Calibration of test cables
• Automatic regulation of noise voltage disturbances

 

THT600 INFRARED CAMERA 384X288PXL

• IR Resolution 384x288 pxl
• Temperature range -20° ÷ 650°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 17° x 12.7°

 

HT I-V500W PHOTOVOLTAIC SYSTEM ANALYZER WITH I-V CURVE TRACER 1500V 15A

• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
• Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A
• Measurement of open-circuit voltage and short-circuit current Voc/Isc
• Database of 30.000 selectable photovoltaic modules

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

FULLTEST3 MULTIFUNCTION TESTER FOR SAFETY OF MACHINERY IEC/EN60204-1 AND LOW VOLTAGE SWITCHGEARS AND CONTROLGEARS IEC/EN61439-1-2

• IEC/EN60204-1 and IEC/EN61439-1-2 Measuments
• Continuity of protective circuit with 200mA
• Continuity of protective circuit with I>10A, V<12V
• Continuity of protective circuit with I>25A, V<12V
• Insulation with test voltages 100, 250, 500, 1000VDC
• Dielectric strength with voltage programmable from 250V to 5100VAC