YOKOGAWA Clamp-on Tester CL135 (True RMS, ACA, ACV, 600A)

Cod: YOKOGAWA CL135


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 600A
  • AC voltage and resistance measurements
  • 30mm in diameter of measurable conductor
  • True RMS Display
  • Data hold function
  • Approved for comformity to safety standard EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. Ill 600 V)

 

Display (LCD, Digital Counts)

1999

AC Current Accuracy (200A Reference)

1.5+4(50/60Hz)
2.0+5(40~1kHz)

AC Current Accuracy (600A Reference)

1.5+4(50/60Hz)
2.0+5(40~1kHz)

AC Voltage Accuracy (200V/600V Reference)

1.0+2(50/60Hz)
1.5+4(40~1kHz)

Crest Factor

(50/60Hz)

Resistance Accuracy (200O reference)

1.2+4, Beeps at below 30O (continuity check)

Method of detection

True RMS

Response Time

Approx. 1 seconds (approx. 2 seconds on resistance range)

Range Switching

Manual-range

Data hold

On all range

Operating temperature and humidity

-10-50°C. (no condensation)
up to 30°C, 90% RH
up to 40°C, 75% RH
up to 50°C, 45% RH

Influence of external magnetic field

2A or less at 400A/m

Influence of conductor position

± 3% or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

600Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

6F22(006P)9Vx1 or 6LR61x2

Battery Life1

100 hours

Consumed current

Approx. 2mA

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

30mm at maximum

Dimensions

Approx. 93(W)x210(H)x40(D)mm

Weight (Approx.)

400g

Accessories

Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

 

 

Alte produse YOKOGAWA

YOKOGAWA CLAMP-ON TESTER CL220 (AC/DC 300A)

• AC/DC current measurements with current ranges up to 300A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display
• Sleep function

 

YOKOGAWA MANOMETRU DIGITAL MT220

• Measurement with DCV and DCA
• 24 V DC output
• Percent reading
• Error reading
• Measurement data memory

 

YOKOGAWA - SL1000 UNITATE ACHIZITII DE DATE VITEZA INALTA

• Fast Acquisition
• Fast Transfer and Storage
• Easy to use
• Can operate "Standalone"

 

YOKOGAWA CLAMP-ON TESTER CL135 (TRUE RMS, ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• True RMS Display
• Data hold function

 

YOKOGAWA CALIBRATOR DE PROCES CA300 CA310 CA320 CA330

• Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
• Simultaneously supplies 24V loop power and measure output signal with high accuracy
• Sub display displays span% of the source value
• HART/BRAIN comm. resistance (250O) embedded

 

YOKOGAWA 2560A HIGH VOLTAGE AND HIGH CURRENT PRECISION DC CALIBRATOR

• Wide output range of voltage and current generation
• Dials and switches for each digit and function
• High accuracy, stability, and resolution
• Various effective functions for analog meters calibration.

 

YOKOGAWA DM7560 DIGITAL MULTIMETER 6.5 DIGIT

• Full-color,high-resolution display with flexible display formats
• High-speed data logging with up to 30 k points per second
• High-capacity internal memory up to 100 k points
• Trend / histogram analysis available both in real-time and offline

 

YOKOGAWA TESTER ANALOGIC SCURGERI CURENTI 322610 (ANALOG)

• ± 2.5% full scale accuracy
• 100µA full scale value
• Shockproof indicator using taut band movement
• Built-in overload protection circuit
• Handy and easy to carry

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA DIGITAL RESISTANCE METER 7556

• Wide operating rangeability (1 Ohm range to 100 M Ohm range)
• Full remote controlability via the standard RS232C serial, or optional GP-IB interfaces
• Software based calibration
• Printer output of measurement, and statistical analysis results