YOKOGAWA Clamp-on Tester CL135 (True RMS, ACA, ACV, 600A)

Cod: YOKOGAWA CL135


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 600A
  • AC voltage and resistance measurements
  • 30mm in diameter of measurable conductor
  • True RMS Display
  • Data hold function
  • Approved for comformity to safety standard EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. Ill 600 V)

 

Display (LCD, Digital Counts)

1999

AC Current Accuracy (200A Reference)

1.5+4(50/60Hz)
2.0+5(40~1kHz)

AC Current Accuracy (600A Reference)

1.5+4(50/60Hz)
2.0+5(40~1kHz)

AC Voltage Accuracy (200V/600V Reference)

1.0+2(50/60Hz)
1.5+4(40~1kHz)

Crest Factor

(50/60Hz)

Resistance Accuracy (200O reference)

1.2+4, Beeps at below 30O (continuity check)

Method of detection

True RMS

Response Time

Approx. 1 seconds (approx. 2 seconds on resistance range)

Range Switching

Manual-range

Data hold

On all range

Operating temperature and humidity

-10-50°C. (no condensation)
up to 30°C, 90% RH
up to 40°C, 75% RH
up to 50°C, 45% RH

Influence of external magnetic field

2A or less at 400A/m

Influence of conductor position

± 3% or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

600Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

6F22(006P)9Vx1 or 6LR61x2

Battery Life1

100 hours

Consumed current

Approx. 2mA

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

30mm at maximum

Dimensions

Approx. 93(W)x210(H)x40(D)mm

Weight (Approx.)

400g

Accessories

Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

 

 

Alte produse YOKOGAWA

YOKOGAWA LS3300 AC POWER CALIBRATOR

• High Accuracy
• Phase Accuracy
• High Stability
• Wide generation range
• Single to three phase power calibration

 

YOKOGAWA MULTIMETRU DIGITAL PORTABIL TY710

• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
• Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
• Operating temperature range -20 to +55C
• Storage temperature range -40 to +70
• Closed Case Calibration

 

YOKOGAWA - WT3000E ANALIZOR DE PUTERE DE PRECIZIE

• Basic power accuracy: 0.01% of reading
• Both 2 A and 30 A input elements can be installed in a single unit
• Good readability: 8.4-inch LCD and the range indicator LEDs
• Simultaneous measurement with 2 units (Up to 8 power input elements)
• Store function: 50 ms data storing interval

 

YOKOGAWA DIGITAL RESISTANCE METER 7556

• Wide operating rangeability (1 Ohm range to 100 M Ohm range)
• Full remote controlability via the standard RS232C serial, or optional GP-IB interfaces
• Software based calibration
• Printer output of measurement, and statistical analysis results

 

YOKOGAWA - DLM4000 OSCILOSCOP DIGITAL SEMNALE MIXTE

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows

 

YOKOGAWA AQ6373B ANALIZOR SPECTRU OPTIC VIZIBIL 350 - 1200 NM

• Max safe input power: +20 dBm
• Level sensitivity: -80 dBm
• Dynamic range: ?60dB
• Single-mode, Multimode, and Large-core fibers
• Built-in optical alignment source

 

YOKOGAWA GS820 MULTI CHANNEL SOURCE MEASURE UNIT

• DC voltage/current reference, pulse voltage/current source
• V-I curve trace, semiconductor parametric test
• Programmable arbitrary waveform generation
• Electric load, resistance measurement
• Production test

 

YOKOGAWA AQ2211 FRAME CONTROLLER (3 SLOTS)

• Easy-to-view color display
• USB port for data storage
• Measurement module "hot-swapping" capability
• Remote monitoring and measurement through a LAN

 

YOKOGAWA DMM PORTABIL TY530

• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety
• Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV

 

YOKOGAWA PROCESS MULTIMETER CA450

• Simultaneous 24 V loop power and mA measurement
• HART mode setting with loop power (250 OHM resistance)
• High accuracy signal measurement: DC mA 0.05%/30.000 mA
• Handheld DMM function
• Peak/Hold function for DCS power peak-to-peak measurement