Cod: Vanguard LTCA-40
Descriere
The LTCA-40 Analyzer is a second generation load tap changer analyzer. The LTCA-40 accurately measures winding resistance of highly inductive power transformers. Triple resistance-reading channels allow the measurement of three winding resistances simultaneously. Four-wire (Kelvin) connections provide high accuracy and require no lead compensation. A special feature of this device is its ability to measure and graph the resistance trace of a transformer LTC during operation. Using a 60Vdc power supply, the LTCA-40 is capable of outputting 40 amperes.
Transformer Load Tap Changer
Control
Transformer tap positions can be changed remotely using
the unit’s built-in transformer load tap changer. This
remote-controlled tap changer feature eliminates the
need to manually change a transformer’s step-up and
step-down taps.
Built-in Safety Features
At the end of each test, the LTCA-40 automatically
dissipates the stored energy in the transformer.
This discharge circuit will continue to
work even if the supply voltage is lost.
AC Motor Current Monitoring
One AC current monitoring channel is dedicated
to monitoring the LTC voltage regulator motor
current during operation. The motor current is
also printed on the resistance graph and can
help detect LTC voltage regulator motor problems.
An AC clamp-on current sensor is provided
with the LTCA-40.
Built-in Thermal Printer
The built-in 4.5-inch wide thermal printer can
print the breaker contact analysis results in both
tabular and graphic formats.
Resistance Reading Features
Three resistance-reading channels can measure resistance
from 1 micro-ohm to 500 ohms, and the test current
is programmable (1A, 5A, 10A, 40A). The LTCA-40
can also be used to measure EHV circuit-breaker contact
resistance, motor winding resistance or any low resistance.
If the transformer winding temperature is entered,
the LTCA-40 can calculate the equivalent resistance
value of the winding material (aluminum or copper) at
any standard reference temperature. Also, a special test
mode can run a test for up to 45 minutes while saving
resistance readings at one-minute intervals.
Dynamic Resistance Test
Features
One resistance reading channel is dedicated to
dynamic resistance testing. This test can monitor
the LTC voltage regulator contact resistance
during operation. A resistance graph, plotting
resistance over time, can be printed on the builtin
thermal printer and is very useful for detecting
LTC voltage regulator contact problems.
Accesorii standard
Part number LTCA-40 LTCA-40, cables, software
Part number LTCA-40 CASE LTCA-40 shipping case
Part number TP4 4.5-inch wide thermal printer paper
Alte produse VANGUARD
|
TESTER MASURARE RAPORT DE TRANSFORMARE TRANSFORMATOARE VANGUARD ATRT-01
• Displays turns-ratio from 0.8-15,000 |
|
ANALIZOR INTRERUPATOARE TIMP ACTIONARE VANGUARD CT-7000
• dry-contact inputs: 3 channels (9021-UC) or 6 channels (9100-UC) |
|
ANALIZOR COMUTATOARE PLOTURI IN SARCINA SI REZISTENTA INFASURARI TRANSFORMATOARE VANGUARD LTCA-10
• Auto discharge circuit for operator safety |
|
PUNTE MASURA REZISTENTA INFASURARE TRANSFORMATOR VANGUARD TRM-20
• accurately measure resistance values from 1 micro-ohm to 2,000 Ohms |
|
ANALIZOR CIRCUITE INTRERUPATOARE INALTA TENSIUNE VANGUARD DIGITMR PC
• dry-contact inputs 3 dry-contact channels |
|
ANALIZOR INTRERUPATOARE STICLA CU VID INALTA TENSIUNE VANGUARD VBT-60 / 80
• Automatic Testing |
|
TRUSA TESTARE TRANSFORMATOARE DE CURENT, RAPORT TRANSFORMARE, CURBA EXCITATIE, GRAFIC SATURATIE VANGUARD EZCT-2000C PLUS
• Performs CT excitation, current-ratio, polarity, and phase angle tests |
|
ANALIZOR DE INTRERUPATOARE TRIPOLARE AUTOMATE VANGUARD CT-3500
• Dry-contact inputs: 3 channels |
|
ANALIZOR INTRERUPATOARE CU CARCASA TURNATA SI RELEE PROTECTIE SUPRASARCINA MOTOR VANGUARD MCCB-250
• 250 Ampere current source |
|
TESTER RAPORT TRANSFORMARE TRANSFORMATOARE DE TENSIUNE CAPACITIVE VANGUARD CVT-765
• Standalone or computer-controlled |