Trusa testare transformatoare de curent, raport transformare, curba excitatie, grafic saturatie Vanguard EZCT-2000C Plus

Cod: Vanguard EZCT-2000C Plus


 

Brosura produs PDF, 1.09 Mb
       

Descriere

  • Performs CT excitation, current-ratio, polarity, and phase angle tests
  • Measures insulation resistance and winding resistance of the CT seconday windings
  • Measures the CT's secondary burden
  • Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
  • Built-in 4.5-inch wide thermal printer
  • Plot Multiple Saturation Curves
  • Stores up to 128 CT test plans and 140 test records internally
  • USB, Bluetooth, and USB Flash drive interface

 

 

The EZCT-2000C Plus is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C Plus has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:

  • Performs CT excitation, current-ratio, polarity, and phase angle tests
  • Measures insulation resistance and winding resistance of the CT secondary windings
  • Measures the CT’s load burden
  • Standalone or computer-controlled via USB or Bluetooth wireless interface

The EZCT-2000C Plus’ test leads can be connected to all the CT output terminals, and the complete CT test can be performed automatically without any operator intervention.

 

Excitation Test

The CT excitation test is performed using the

ANSI/IEEE C57.13.1 test method. Test voltage

ranges from 50, 300, 500,1200 and 2000 Vac

can be selected for the excitation test. The test

voltage is raised and lowered automatically by

the EZCT-2000C Plus. The excitation test voltage

and current data is collected and stored in

the unit's internal memory. Knee point voltages

(ANSI 10/50, IEC 60044, IEEE-30, IEEE-45) are

calculated and printed on the test report. All of

the test leads can be connected to the CT output

terminals (X1, X2, X3, X4 and X5), and there is

no lead switching required during testing. This

convenient arrangement allows for testing any

of the 10 possible combinations of X1 to X5. Up

to 10 excitation tests can be stored in one record.

Once the test is completed, the test report

and CT excitation curves can be printed on the

built-in thermal printer.

 

Demagnetization

The EZCT-2000C Plus automatically demagnetizes

the CT under test when performing an

excitation test.

 

Winding Resistance Test

The EZCT-2000C Plus can measure the DC

resistance of transformer windings from 100

micro-ohms to 10 ohms.

 

CT Winding Insulation

Resistance Test Feature

The EZCT-2000C Plus offers an IR test feature

that can also measure the insulation resistance

of the CT’s secondary winding using a test voltage

up to 1000 Vdc. The DC winding resistance

reading range is from 2 to 500 Mega-ohms. The

insulation resistance test results are displayed

and printed on the report.

 

Ratio and Polarity Tests

The CT current-ratio is determined using the

ANSI/IEEE C57.12.90 measurement method. A

test voltage is applied on any two terminals (X1

to X5) of the CT, and the induced voltage is measured

through the H1 and H2 terminals of the CT.

The CT current-ratio is displayed and also stored

in memory. The current-ratio is measured from

0.8 to 5,000. The CT winding polarity is displayed

as a "+" sign (in-phase) or a "-" sign (outof-

phase) and is annotated with the phase angle

in degrees. The CT current ratio error and phase

displacement is also calculated based on the CT

burden (or rated power) and rated current.

 

CT Burden Test

The EZCT-2000C Plus can measure the CT’s actual

connected burden by injecting a 1A or 5A

test current into the load. The CT burden measurements

(Voltage, current, Cos f, and burden

impedance) are displayed on the screen and

printed on the test report. This important test

verifi es the actual CT measured burden before

putting the CT in service, thus avoiding any potential

confi guration confl icts.

 

 

Accesorii standard

 

 

Alte produse VANGUARD

MICROOHMMETRU AUTOMATIC REZISTENTE DE CONTACT INTRERUPATOARE 200A VANGUARD AUTO-OHM 200 S3

• 1 to 200A programmable test current
• Resitance range: 1µ?..10m? at 200A to 1µ?..5? at 1A
• Very lightweight: 16.8 lbs. (7.6 Kg)
• Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
• Stores test records on-board or on external USB Flash drive
• Rugged, 44-key "QWERTY" membrane keypad
• Windows XP/Vista/7 Analysis Software (included with purchase)

 

ANALIZOR COMUTATOR PLOTURI IN SARCINA SI REZISTENTA INFASURARE TRANSFORMATOR TRIFAZAT VANGUARD LTCA-40

• Auto discharge circuit for operator safety
• 3 resistance reading channels including one dynamic channel
• Digital resistance reading from 1 micro-ohm to 500 ohms
• 60Vdc power supply , outputting 40 amperes
• Calculate equivalent resistance value at reference temperature
• Stores 50 static records and 20 dynamic records
• Built-in 4.5-inch thermal printer

 

TRUSA INJECTIE CURENTI PRIMARI 600A AC TESTARE RELEE DE PROTECTIE VANGUARD PCI-600

• Results displayed on a 4-line by 20-character backlit LCD
• Test currents from 10 to 600 amperes AC
• Also has an external-current input (0-10 A)
• timer reading range 1 m.. 2 hours

 

OHMMETRU REZISTENTA INFASURARI SI BOBINAJ TRANSFORMATOARE INDUCTIVE DE MARE PUTERE VANGUARD WRM-10P

• Range from 1 micro-ohm to 2,000 ohm
• Up to 10 Amperes of test current
• Auto discharge circuit for operator safety
• Built-in 2.5" Thermal Printer, computer interface
• Stores 48 records of 63 readings
• Weighs less than 27 lbs.

 

TESTER AUTOMAT MASURA TRANSFORMARE TRANSFORMATOARE TRIFAZATE VANGUARD TRI-PHASE

• Generates its own 3-phase transformer test voltage from single-phase AC or DC Power input
• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC,
• 64 x 128 graphic LCD screen
• Store up to 128 transformer test-plans in Flash EEPROM
• Store up to 112 test records in Flash EEPROM
• Built-in USB Flash Drive Interface
• Computer Interface (RS-232C and USB Port)
• 4.5 Inch thermal printer
• Built-in transformer load tap changer

 

ANALIZOR INTRERUPATOARE TIMPI SI REZISTENTA DE CONTACT COMUTATOARE VANGUARD CT-8000

• dry-contact inputs 3 channels (9103-UC) or 6 channels (9104-UC)
• timing windows 1 second, 10 seconds, or 20 seconds
• timing resolutions ±50 micro-seconds @ 1 sec. duration
• Fully analyze circuit breaker's performance
• measuring main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes
• USB computer interface
• Built-in 4.5" wide Thermal Printer

 

PUNTE TESTARE REZISTENTE INFASURARI TRANSFORMATOARE VANGUARD TRM-40

• accurately measure resistance values from 1 micro-ohm to 500 Ohms
• Auto-discharge circuit for operator safety
• Demagnetizes transformer after test
• Selectable test current from 1A to 40A
• RS-232C, USB, and Bluetooth computer interfaces
• Built-in thermal printer

 

ANALIZOR CIRCUITE INTRERUPATOARE INALTA TENSIUNE VANGUARD DIGITMR PC

• dry-contact inputs 3 dry-contact channels
• timing windows 1 second, 10 seconds, or 20 seconds
• timing resolutions ±50 micro-seconds @ 1 sec. duration
• Inexpensive, PC-controlled EHV circuit breaker analyzer
• Optional "on-line" timing mode
• Small and light-weight
• Can test contact time, stroke, velocity, over-travel, and contact wipe

 

SURSA DE PUTERE CURENT 10A AC/DC REGLABILA PENTRU TESTARE INTRERUPATOARE SI RELEE DE PROTECTIE VANGUARD UPS-S2

• Isolated variable 1-300 Vdc source
• Isolated variable 1-240 Vac source
• 10 ampere continuous current

 

TESTER RAPORT TRANSFORMARE TRANSFORMATOARE DE TENSIUNE CAPACITIVE VANGUARD CVT-765

• Standalone or computer-controlled
• Can test CVT's rated up to 765 KV
• Displays turns-ratios from 75-15,000
• Calculates turns-ratio percentage error when nameplate voltages are provided