Termometru de precizie portabil Delta Ohm HD2107.1 HD2107.2 HD2127.1 HD2127.2

Cod: HD2107.1 HD2107.2 HD2127.1 HD2127.2


 

Brosura produs PDF, 0.27 Mb
 

Descriere

Centesimal thermometer in the range +/-199.99°C, decimal outside this range, one input for Pt100 probes with SICRAM module measuring range -200°C +650°C. Storage of maximum, minimum, average value, RS232 C output for data transfer in real time to a PC or printer. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 4 batteries, Software DeltaLog 9. The probes and cables for data download have to be ordered separately. TP47Â... series probes are suitable.

 

Alte produse SENSECA

DATALOGGER MULTIFUNCTIONAL CU ANALIZA MICROCLIMA DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

PIRANOMETRU CU FOTODIODA SILICONICA MASURA RADIATIE SOLARA GLOBALA PANOURI FOTOVOLTAICE DELTA OHM LP SILICON-PYRA04

• LP Silicon-PYRA 04. pyranometer
• measures the global solar radiation (W/m2) by using a silicon photodiode (400nm-1100nm).
• special geometry and the diffuser allow to have a pyranometer field of view of 180 degrees according to cosine law.
• The pyranometer is suitable for the measurement of natural sunlight.

 

ANALIZOR AUDIO SUNET CLASA I CU DATALOGGER, ANALIZA SPECTRU ACUSTIC OCTAVA 3A, STATISTICI DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

PH-METRU TERMOMETRU CU DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

TERMOMETRU DIGITAL PORTABIL SENZOR PT100 -200°C +650°C DELTA OHM HD2307.0

• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module,
• measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• Functions: REL, HOLD and auto-power-off which can be disabled
• IP 67 protection degree

 

DATALOGGER ANALIZA MONITORIZARE CALITATE MEDIU AER, MONOXID, BIOXID CARBON DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

TESTER OXIGEN DIZOLVAT SI TERMOMETRU CU DATALOGGING DELTA OHM HD2109.1 HD2109.2

• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.