Luxmetru foto-radiometru masura iluminanta, PAR, iradianta solara Delta Ohm HD2102.1 HD2102.2

Cod: Delta Ohm HD2102.1 HD2102.2


 

Brosura produs PDF, 0.54 Mb

Descriere

Device for measuring illuminance, luminance, PAR, irradiance. Storage of maximum, minimum, average value and the integral Q(t), RS232 C output for data transfer in real time to a PC or printer. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 4 batteries, Software DeltaLog 9. LP471.. series probes with SICRAM module are suitable. The probes and cables for data download have to be ordered separately
 

Alte produse SENSECA

ANALIZOR VIBRATII 4-CANALE PROTECTIE VIBRATII MECANICE LOC DE MUNCA DELTA OHM HD2030

• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• satisfies the specifications of standards ISO 8041:2005, ISO 5349-1:2001 (handarm vibrations)
• ISO 2631-1, 2 and 4 1997 (whole-body vibrations)
• detects accelerations on four axes through two accelerometers with integrated amplifying electronics

 

DATALOGGER HVACR VITEZA SI DEBIT AER, PRESIUNE, TEMPERATURA, UMIDITATE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


ANEMOMETRU TERMOMETRU MASURA VITEZA AER DELTA OHM HD2303.0

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

TERMO-HIGROMETRU PORTABIL DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

MANOMETRU TERMOMETRU DIGITAL PORTABIL DELTA OHM HD2304.0

• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series
• Temperature measurement with Pt100 probe complete with SICRAM module, measuring range 200°C +650°C.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

ALBEDOMETRU PIRANOMETRU MASURA ALBEDOU SI RADIATIE GLOBALA INCIDENTA DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

TERMOMETRU DE PRECIZIE PORTABIL DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

PIRGEOMETRU METEO MASURA RADIATIE INFRAROSU DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance