Cod: Delta Ohm HD32.1
Descriere
Technical data HD32.1:
Thanks to specific software: Moderate environments, Hot environments, Cold environments and Discomfort, as well as specific probes, the instrument can perform the following measurements:
• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head (1,7m subject standing; 1,1m subject sitting).
• Air temperature at the height of the abdomen (1,1 m subject standing; 0,6m subject sitting).
• Air temperature at the height of the ankles (0,1 m).
• Temperature at the floor level.
• Net radiation temperature.
• Net radiation.
• Radiant temperature asymmetry.
• Illuminance, luminance, PAR, irradiance, CO and CO2.
According to measurements performed, HD32.1, together with its specific software, calculates the following parameters:
• tr : Mean radiant temperature
• PMV : Predicted Mean Vote
• PPD : Predicted Percentage Dissatisfied
• DR : Draught Rating
• tO : Operative temperature
• IS : Scharlau Index
• DI : Thom Index
• THI : Thermohygrometric Index
• RSI : Relative Strain Index
• SSI : New Summer Simmer Index
• HI : Heat Index
• H : Humidex Index
• Teq : Equivalent Temperature Index
To compute the calculation of these indexes, temperature and relative humidity of the air have to be detected and the measured values to be inserted in the table "Discomfort indexes".
• WBGTIndoor : Wet bulb Globe temperature
• WBGTOutdoor : Wet bulb Globe temperature in the presence of radiation
• SWp : Sweat rate
• Ep : Predicted evaporative heat flow
• PHS : Tre - Water loss - Dlim tre - Dlimloss50 - Dlimloss95
• IREQ : Required clothing insulation
• DLE : Duration Limit Exposure
• RT : Recovery time
• WCI : Wind chill index
• PDv : Percentage Dissatisfied due to vertical temperature difference (head-ankles)
• PDf : Percentage Dissatisfied due to floor temperature
• PD? : Percentage Dissatisfied due to radiant asymmetry
• FLD : Average Day Light Factor
The calculation of the FLD index requires light measurement (photometric probe LP-471PHOT). Requires program "HD32.1 prog. C"
HD32.1 Kit basic: It is composed of HD32.1 instrument, A operating program:
Analysis of the Microclimate, four 1.5V alkaline batteries size C-BABY, instruction manual. The instrument includes atmospheric pressure sensor.
DeltaLog10 Basic moderate environments Software (for operating systems from Windows 98 to Windows7).
Alte produse SENSECA
|
TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2
• Thermocouple thermometer with one input and logger 32.000 samples |
|
CALIBRATOR ACUSTIC NIVEL SUNET PENTRU CALIBRARE MICROFON SI STATII ACUSTICE DELTA OHM HD2020
• HD 2020 sound level calibrator |
|
PH-METRU-TERMOMETRU DE LABORATOR CU MASURA PH, MV, POTENTIAL REDOX ORP DELTA OHM HD2205.2
• Bench-top pHmeter-Thermometer with back-lighted display, |
|
TERMOMETRU DE PRECIZIE PORTABIL DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2
• Centesimal thermometer in the range +/-199.99°C, decimal outside this range |
|
SONOMETRU INTEGRATOR CLASA I SI CLASA II CU ANALIZA SPECTRALA SI STATISTICA DELTA OHM HD2010UC
• integrating portable sound level meter performing statistical analysis |
|
MANOMETRU TERMOMETRU DIGITAL PORTABIL DELTA OHM HD2304.0
• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series |
|
PIRANOMETRU CLASA A 2A IN CONFORMITATE CU STANDARDUL ISO9060 DELTA OHM LP PYRA08
• Second class pyranometer according to ISO 9060, |
|
PH-METRU PORTABIL CU TERMOMETRU DELTA OHM HD2305.0
• pHmeter-Thermometer which measures pH, mV and temperature. |
|
DATALOGGER 8-16 CANALE INREGISTRARE TEMPERATURA DELTA OHM HD32.7 HD32.8.8 HD32.8.16
• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES |
|
ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2
• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module. |